2,561 research outputs found

    Effects of the Amount of Fillers and of the Crosslink Density on the Mechanical Behavior of Carbon-Black Filled Styrene Butadiene Rubbers

    Get PDF
    Several carbon-black filled styrene-butadiene rubbers are subjected to monotonic uniaxial tension tests in order to investi-gate the effects of the amount of fillers and of the crosslink density on their mechanical properties. The Young modulus, the volume changes associated with material damage and the stretch to failure are extracted and discussed. Results compare well to the literature results when exist and quantitative analysis are proposed when possible. Results show that filled rubbers are not incompressible when submitted to uniaxial tension tests and their volume changes are strongly dependent of the amount of fillers but are unaffected by the crosslink density. The latter shows strong impact on the filled rubbers stretch to failure but more interestingly this impact is com-parable to what is encountered in unfilled rubbers. The stretch to failure is improved by the addition of fillers with an optimum for material filled around 30 phr

    Anomalous diffusion mediated by atom deposition into a porous substrate

    Full text link
    Constant flux atom deposition into a porous medium is shown to generate a dense overlayer and a diffusion profile. Scaling analysis shows that the overlayer acts as a dynamic control for atomic diffusion in the porous substrate. This is modeled by generalizing the porous diffusion equation with a time-dependent diffusion coefficient equivalent to a nonlinear rescaling of timeComment: 4 page

    Effect of Hydrodynamic Force on Microcantilever Vibrations: Applications to Liquid-Phase Chemical Sensing

    Get PDF
    At the microscale, cantilever vibrations depend not only on the microstructure’s properties and geometry but also on the properties of the surrounding medium. In fact, when a microcantilever vibrates in a fluid, the fluid offers resistance to the motion of the beam. The study of the influence of the hydrodynamic force on the microcantilever’s vibrational spectrum can be used to either (1) optimize the use of microcantilevers for chemical detection in liquid media or (2) extract the mechanical properties of the fluid. The classical method for application (1) in gas is to operate the microcantilever in the dynamic transverse bending mode for chemical detection. However, the performance of microcantilevers excited in this standard out-of-plane dynamic mode drastically decreases in viscous liquid media. When immersed in liquids, in order to limit the decrease of both the resonant frequency and the quality factor, and improve sensitivity in sensing applications, alternative vibration modes that primarily shear the fluid (rather than involving motion normal to the fluid/beam interface) have been studied and tested: these include in-plane vibration modes (lateral bending mode and elongation mode). For application (2), the classical method to measure the rheological properties of fluids is to use a rheometer. However, such systems require sampling (no in-situ measurements) and a relatively large sample volume (a few milliliters). Moreover, the frequency range is limited to low frequencies (less than 200Hz). To overcome the limitations of this classical method, an alternative method based on the use of silicon microcantilevers is presented. The method, which is based on the use of analytical equations for the hydrodynamic force, permits the measurement of the complex shear modulus of viscoelastic fluids over a wide frequency range

    Loss of strength in Ni3Al at elevated temperatures

    Get PDF
    Stress decrease above the stress peak temperature (750 K) is studied in h123i single crystals of Ni3(Al, 3 at.% Hf ). Two thermally activated deformation mechanisms are evidenced on the basis of stress relaxation and strain rate change experiments. From 500 to 1070 K, the continuity of the activation volume/temperature curves reveals a single mechanism of activation enthalpy 3.8 eV/atom and volume 90 b3 at 810K with an athermal stress of 330 MPa. Over the very same temperature interval, impurity or solute diffusion towards dislocation cores is evidenced through serrated yielding, peculiar shapes of stress–strain curves while changing the rate of straining and stress relaxation experiments. This complicates the identification of the deformation mechanism, which is likely connected with cube glide. From 1070 to 1270 K, the high-temperature mechanism has an activation enthalpy and volume of 4.8 eV/atom and 20 b3, respectively, at 1250 K

    Predicting dislocation climb: Classical modeling versus atomistic simulations

    Get PDF
    The classical modeling of dislocation climb based on a continuous description of vacancy diffusion is compared to recent atomistic simulations of dislocation climb in body-centered cubic iron under vacancy supersaturation [Phys. Rev. Lett. 105 095501 (2010)]. A quantitative agreement is obtained, showing the ability of the classical approach to describe dislocation climb. The analytical model is then used to extrapolate dislocation climb velocities to lower dislocation densities, in the range corresponding to experiments. This allows testing of the validity of the pure climb creep model proposed by Kabir et al. [Phys. Rev. Lett. 105 095501 (2010)]

    Results of a feasibility study: barriers and facilitators in implementing the Sherbrooke model in France.

    Get PDF
    OBJECTIVES: Return-to-work interventions associated with the workplace environment are often more effective than conventional care. The Sherbrooke model is an integrated intervention that has proved successful in preventing work disability due to low-back pain. Implementation, however, runs up against many obstacles, and failure has been reported in many countries. The present study sought to identify barriers to and facilitators of the implementation of the Sherbrooke model within the French health system. METHODS: A multiple case study with nested levels of analysis was performed in two regions of France. A conceptual framework was designed and refined to identify barriers and facilitators at the individual, organizational and contextual levels. Qualitative data were collected via semi-structured interview (N=22), focus groups (N=7), and observation and from the gray literature. Participants (N=61) belonged to three fields: healthcare, social insurance, and the workplace. RESULTS: Numerous barriers and facilitators were identified in each field and at each level, some specific and others common to workers in all fields. Individual and organizational barriers comprised lack of time and resources, discordant professional values, and perceived risk. Legal barriers comprised medical confidentiality, legal complexity, and priority given to primary prevention. Individual-level facilitators comprised needs and perceived benefits. Some organizations had concordant values and practices. Legal facilitators comprised possibilities of collaboration and gradual return to work. CONCLUSION: The present feasibility analysis of implementing the Sherbrooke model revealed numerous barriers and facilitators suggesting a new implementation strategy be drawn up if failure is to be avoided

    Influence of Fluid-Structure Interaction on Microcantilever Vibrations: Applications to Rheological Fluid Measurement and Chemical Detection

    Get PDF
    At the microscale, cantilever vibrations depend not only on the microstructure’s properties and geometry but also on the properties of the surrounding medium. In fact, when a microcantilever vibrates in a fluid, the fluid offers resistance to the motion of the beam. The study of the influence of the hydrodynamic force on the microcantilever’s vibrational spectrum can be used to either (1) optimize the use of microcantilevers for chemical detection in liquid media or (2) extract the mechanical properties of the fluid. The classical method for application (1) in gas is to operate the microcantilever in the dynamic transverse bending mode for chemical detection. However, the performance of microcantilevers excited in this standard out-of-plane dynamic mode drastically decreases in viscous liquid media. When immersed in liquids, in order to limit the decrease of both the resonant frequency and the quality factor, alternative vibration modes that primarily shear the fluid (rather than involving motion normal to the fluid/beam interface) have been studied and tested: these include inplane vibration modes (lateral bending mode and elongation mode). For application (2), the classical method to measure the rheological properties of fluids is to use a rheometer. To overcome the limitations of this classical method, an alternative method based on the use of silicon microcantilevers is presented. The method, which is based on the use of analytical equations for the hydrodynamic force, permits the measurement of the complex shear modulus of viscoelastic fluids over a wide frequency range
    corecore