104 research outputs found

    The ART approach: clinical aspects reviewed

    Get PDF
    The success of ART as a caries management approach is supported by more than 20 years of scientific evidence. ART follows the contemporary concepts of modern cariology and restorative dentistry. It challenges treatment concepts such as step-wise excavation and the need for complete removal of affected dentine. The ART approach so far has mainly used high-viscosity glass-ionomer as the sealant and restorative material. Cariostatic and remineralization properties have been ascribed to this material which requires further research to establish its clinical relevance. The adhesion of high-viscosity glass-ionomer to enamel in pits and fissures is apparently strong, as its remnants, blocking the pits and fissures, have been considered a possible reason for the low prevalence of carious lesion development after the glass-ionomer has clinically disappeared from it. Encapsulated high-viscosity glass-ionomers may lead to higher restoration survival results than those of the hand-mixed version and should, therefore, not be neglected when using ART. Similarly, the use of resin-modified glass-ionomer with ART should be researched. The effectiveness of ART when compared to conventional caries management approaches has been shown in numerous studies. Proper case selection is an important factor for long-lasting ART restoration survival. This is based on the caries risk situation of the individual, the size of the cavity opening, the strategic position of the cavitated tooth and the presence of adequate caries control measures. As the operator is one of the main causes for failure of ART restorations, attending a well-conducted ART training course is mandatory for successful implementation of ART

    Surface gloss, gloss retention, and color stability of 2 nano-filled universal resin composites

    Get PDF
    Fil: Molina, Gustavo Fabián. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales. Argentina.Fil: Molina, Gustavo Fabián. Universidad Católica de Córdoba. Facultad de Ciencias de la Salud. Cátedra de Materiales Dentales. Argentina.Fil: Molina, Gustavo Fabián. University of Hong Kong . Faculty of Dentistry. Restorative Dental Sciences Division; China.Fil: Cabral, Ricardo Juan. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina.Fil: Mazzola, Ignacio. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales. Argentina.Fil: Mazzola, Ignacio. Universidad Católica de Córdoba. Facultad de Ciencias de la Salud. Cátedra de Materiales Dentales. Argentina.Fil: Burrow, Michael. University of Hong Kong . Faculty of Dentistry. Restorative Dental Sciences Division; China.This study compared the surface gloss (SG), gloss retention (GR), and color stability (CS) of 2 universal resin composites after chemical (CA) and mechanical (MA) aging.Materials and MethodsTwenty disc-shaped samples of G-ænial A´Chord (GC-Europe) and Filtek Universal (3M-ESPE) were polished with sequential abrasive papers. For CA, specimens were stored in 1 mL of 75% ethanol for 15 days at 37°C, and readings (SG, GR, and CS) were obtained at baseline and 5, 10, and 15 days. For MA, specimens were subjected to 10,750 simulated brushing cycles. SG and CS were evaluated after every 3,583 cycles. SG was measured with a glossmeter (geometrical configuration: 60°), and values were expressed in gloss units. Color was measured with a spectrophotometer using the CIE-L*a*b* color system. The Student?s t-test, 1-way analysis of variance, and Scheffé test were used for statistical analysis (α = 0.05).ResultsG-ænial presented significantly higher SG values than Filtek (p = 0.02), with GR reductions of 5.2% (CA) and 5.3% (MA) for G-ænial and 7.6% (CA) and 7.2% (MA) for Filtek. The aging protocol had no statistically significant effect on SG or GR (p = 0.25) from baseline to the final readings. G-ænial?MA presented the lowest color difference (∆E = 1.8), and G-ænial?CA and Filtek?CA had the largest changes (∆E = 8.6 and ∆E = 11.8, respectively).ConclusionG-ænial presented higher SG values and better CS. Both restorative materials demonstrated acceptable GR and CS. Aging protocols impacted these properties negatively.https://rde.ac/DOIx.php?id=10.5395/rde.2022.47.e43info:eu-repo/semantics/publishedVersionFil: Molina, Gustavo Fabián. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales. Argentina.Fil: Molina, Gustavo Fabián. Universidad Católica de Córdoba. Facultad de Ciencias de la Salud. Cátedra de Materiales Dentales. Argentina.Fil: Molina, Gustavo Fabián. University of Hong Kong . Faculty of Dentistry. Restorative Dental Sciences Division; China.Fil: Cabral, Ricardo Juan. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina.Fil: Mazzola, Ignacio. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales. Argentina.Fil: Mazzola, Ignacio. Universidad Católica de Córdoba. Facultad de Ciencias de la Salud. Cátedra de Materiales Dentales. Argentina.Fil: Burrow, Michael. University of Hong Kong . Faculty of Dentistry. Restorative Dental Sciences Division; China.Otras Ciencias Médica

    Biaxial Flexural Strenght of high-viscosity glass-ionomer cements heat-cured with an LED lamp during setting

    Get PDF
    Adding heat to glass ionomers during setting might improve mechanical properties. The aim was to compare the biaxial flexural strength (BFS) between and within four glass ionomers, by time of exposure to a high-intensity LED light-curing unit. Materials and methods. Samples of Fuji 9 Gold Label, Ketac Molar Easymix, ChemFil Rock, and the EQUIA system were divided into three treatment groups (n=30): without heating (Group 1), heated with LED lamp of 1400 mW/cm2 for 30 s while setting (Group 2), and heated with LED lamp of 1400 mW/cm2 for 60 s while setting (Group 3). Samples were stored for 48 hours in distilled water at 37°C until tested. BFS was tested, using a universal testing machine at a crosshead speed of 1 mm/min. Data were analyzed, using ANOVA test with the Bonferroni correction ( = 0.05). Heating the glass-ionomer cements with an LED curing light of 1400 mW/cm2 during setting for 30 s increased the BFS value of all GICs. No statistically significant difference in mean BFS scores was found between the EQUIA system and ChemFil Rock at 30 s and 60 s. The mean BFS value was statistically significantly higher for the EQUIA system and ChemFil Rock than for Fuji 9 Gold Label and Ketac Molar Easymix at all exposure times.publishedVersionMolina, Gustavo Fabián. Universidad Nacional de Córdoba. Facultad de Odontología. Departamento de Materiales; Argentina.Cabral Ricardo Juan. Universidad Nacional de Córdoba. Facultad de Odontología. Departamento de Materiales; Argentina.Mazzola Ignacio. Universidad Nacional de Córdoba. Facultad de Odontología. Departamento de Materiales; Argentina.Brain Lascano Laura. Universidad Nacional de Córdoba. Facultad de Odontología. Departamento de Materiales; Argentina

    Three-year survival of ART and conventional restorations in patients with disability

    Get PDF
    Fil: Molina, Gustavo Fabián. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina.Fil: Cabral, Ricardo Juan. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina.Fil: Mazzola, Ignacio. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina.Fil: Mulder, Jan. Radboud University Medical Centre; Netherlands.Fil: Frencken, Jo. Radboud University; Netherlands.Caries can be the cause of additional distress and suffering among people with disability. Latest reviews shown that caries prevalence among people with disability is equal to lower compared to people without disability. The main differences between the two groups are the higher number of untreated cavities, the higher prevalence of periodontal problems and the lack of oral health care.https://live.blueskybroadcast.com/bsb/client/_new_default.asp?action=SEARCH&Client=404900Fil: Molina, Gustavo Fabián. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina.Fil: Cabral, Ricardo Juan. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina.Fil: Mazzola, Ignacio. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina.Fil: Mulder, Jan. Radboud University Medical Centre; Netherlands.Fil: Frencken, Jo. Radboud University; Netherlands.Otras Ciencias Médica

    Mechanical performance of encapsulated restorative glass-ionomer cements for use with Atraumatic Restorative Treatment (ART)

    Get PDF
    The Atraumatic Restorative Treatment (ART) approach was suggested to be a suitable method to treat enamel and dentine carious lesions in patients with disabilities. The use of a restorative glass-ionomer with optimal mechanical properties is, therefore, very important. Objective: To test the null-hypotheses that no difference in diametral tensile, compressive and flexural strengths exists between: (1) The EQUIA system and (2) The Chemfil Rock (encapsulated glass-ionomers; test materials) and the Fuji 9 Gold Label and the Ketac Molar Easymix (hand-mixed conventional glass-ionomers; control materials); (3) The EQUIA system and Chemfil Rock. Material and Methods: Specimens for testing flexural (n=240) and diametral tensile (n=80) strengths were prepared according to standardized specifications; the compressive strength (n=80) was measured using a tooth-model of a class II ART restoration. ANOVA and Tukey B tests were used to test for significant differences between dependent and independent variables. Results: The EQUIA system and Chemfil Rock had significantly higher mean scores for all the three strength variables than the Fuji 9 Gold Label and Ketac Molar Easymix (α=0.05). The EQUIA system had significant higher mean scores for diametral tensile and flexural strengths than the Chemfil Rock (α=0.05). Conclusion: The two encapsulated high-viscosity glass-ionomers had significantly higher test values for diametral tensile, flexural and compressive strengths than the commonly used hand-mixed high-viscosity glass-ionomers.http://dx.doi.org/10.1590/1679-775720130129publishedVersionMolina, Gustavo Fabián. Universidad Nacional de Córdoba. Facultad de Odontología. Departamento de Materiales Dentales; ArgentinaCabral, Ricardo Juan. Universidad Nacional de Córdoba. Facultad de Odontología. Departamento de Materiales Dentales; ArgentinaMazzola, Ignacio. Universidad Nacional de Córdoba. Facultad de Odontología. Departamento de Materiales Dentales; ArgentinaBrain Lascano, Laura. Universidad Nacional de Córdoba. Facultad de Odontología. Departamento de Materiales Dentales; ArgentinaFrencken, Jo E. Universidad de Radboud. Facultad de Ciencias Odontológicas. Centro Médico de Nijmegen. Departamento de Salud Oral Global; Países Bajos.Otras Ciencias de la Salu

    Effect of Heat Sources on the Mechanical Poperties of GICS

    Get PDF
    The aims of the present study were to compare: 1)the output temperature of two LED light-curing devices with an average intensity of 1400mW/cm2 after 60 seconds; 2)the influence of the two heat sources at 10, 30 and 60 seconds on the BFS of three encapsulated glassionomer- based restorative cements, and; 3)the effect of time of heat application on the BFS of the three encapsulated GIC?s.Fil: Molina, Gustavo Fabían. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina.Fil: Brain Lascano, Laura C. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina.Fil: Mazzola, Ignacio. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina.Fil: Cabral, Ricardo Juan. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina.Fil: Frencken, Jo. Radboud University; Netherlands.Otras Ciencias de la Salu

    Estudio comparativo de resistencia flexural resinas acrílicas por microondas y alto impacto

    Get PDF
    Introducción: Los materiales para bases de dentaduras completas han evolucionado en sus diversas etapas de desarrollodurante las últimas décadas. El material más utilizado en la elaboración es el polimetacrilato de metilo; sin embargo estematerial no está exento delimitaciones, en términos de resistencia flexural y resistencia al impacto. Se ha demostrado quelas fracturas en la línea media de las bases de dentaduras son comunes. Se han desarrollado resinas acrílicas más fuertescon adición de nuevos materiales,como las resinas acrílicas de alto impacto,cuyos modificadores incluyen copolímeros, agentesde entrecruzamiento y sustancias de goma en forma de estireno butadieno .La adición de +caucho en resinas para basesprocesadas de "alto impacto" en la forma de acrilato de butadieno, produce una mayor resistencia de impacto porque causadispersión de las grietas. Objetivo: evaluar la resistencia a la flexión del acrílico Newcryl de New Stetic, aplicando dos métodosde polimerización, mediante un dispositivo universal de pruebas o probetas para su comparación. Material Método:Se conformaron 2 grupos experimentales (n=20) con probetas de 60± 0,5 mm de diámetro y 3 ± 0,5 mm de grosor,se prepararande acuerdo con los requerimientos que indica la Norma ISO 1567:1999 para realizar los ensayos. Las muestras seconfeccionaran con resina acrílica termocurable por microondas y con resina acrílica de alto impacto que se procesaron contécnica clásica a cada una de las muestras se las monto en una máquina de ensayo universal DIGIMESS de carga uniforme,acción central y perpendicular para medir la deflexión a una velocidad de avance constante de 5mm/min hasta que el espécimenllegó a su máxima resistencia de flexión. Resultados: los discos en microondas registraron valores de resistenciaa la rotura de 12,55+/- 2,46 MPa, en tanto que el grupo de probetas de acrílico de alto impacto tuvo una resistencia de16,87+/- 2,16 MPa (media +/- desviación estándar), resultando estadísticamente significativas las diferencias entre ellos(p<0,05).Conclusión: El estudio y análisis de las propiedades físico-mecánicas, entre otras, las de acrílico de alto impactopresentaron una mejor respuesta mecánica (mayor resistencia flexural) que los acrílicos tratados con microondas.Palabras clave: flexion, microondas, impactoFil: Atala, José Luis. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Prostodoncia II A; Argentina.Fil: Ocampo, Marcelo. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Prostodoncia II A; Argentina.Fil: Cabral, Ricardo Juan. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina.Fil: Ibáñez, Juan Carlos. Universidad Católica de Córdoba; Argentina.Otras Ciencias de la Salu

    Propuesta de incorporación de la Ingeniería de Software Libre y de Código Abierto al currículo de Ingeniería en Sistemas de Información y carreras afines

    Get PDF
    Desde sus inicios el software libre/de código abierto ha generado intensos debates sobre la propiedad intelectual, las libertades del usuario y las formas de creación y distribución de software. Sin embargo, en estos últimos años el debate ha disminuido notablemente ya que ha demostrado ser viable técnica y económicamente, como lo demuestra el hecho de que algunas de las empresas y sistemas más utilizados en la actualidad son o están basados en software libre. El sistema universitario argentino no ha estado libre ni del debate ni de una temprana adopción tanto del software libre como de los principios que dicho software encarna. Sin embargo, existe una carencia en cuanto a asignaturas que cubran tanto los aspectos metodológicos del desarrollo de software libre como los complejos aspectos legales y los siempre cambiantes modelos de negocios. En este trabajo justificamos la importancia de incluir la enseñanza de metodologías de desarrollo de software libre, proponiendo el dictado de un curso de “Ingeniería de software libre” integrado al currículo de la carrera de Ingeniería en Sistemas de Información o afines con el propósito de que los graduados comprendan las particularidades filosóficas, económicas, legales y técnicas de este cambio de paradigma en la ingeniería de software.Sociedad Argentina de Informática e Investigación Operativa (SADIO

    Propuesta de incorporación de la Ingeniería de Software Libre y de Código Abierto al currículo de Ingeniería en Sistemas de Información y carreras afines

    Get PDF
    Desde sus inicios el software libre/de código abierto ha generado intensos debates sobre la propiedad intelectual, las libertades del usuario y las formas de creación y distribución de software. Sin embargo, en estos últimos años el debate ha disminuido notablemente ya que ha demostrado ser viable técnica y económicamente, como lo demuestra el hecho de que algunas de las empresas y sistemas más utilizados en la actualidad son o están basados en software libre. El sistema universitario argentino no ha estado libre ni del debate ni de una temprana adopción tanto del software libre como de los principios que dicho software encarna. Sin embargo, existe una carencia en cuanto a asignaturas que cubran tanto los aspectos metodológicos del desarrollo de software libre como los complejos aspectos legales y los siempre cambiantes modelos de negocios. En este trabajo justificamos la importancia de incluir la enseñanza de metodologías de desarrollo de software libre, proponiendo el dictado de un curso de “Ingeniería de software libre” integrado al currículo de la carrera de Ingeniería en Sistemas de Información o afines con el propósito de que los graduados comprendan las particularidades filosóficas, económicas, legales y técnicas de este cambio de paradigma en la ingeniería de software.Sociedad Argentina de Informática e Investigación Operativa (SADIO

    Propuesta de incorporación de la Ingeniería de Software Libre y de Código Abierto al currículo de Ingeniería en Sistemas de Información y carreras afines

    Get PDF
    Desde sus inicios el software libre/de código abierto ha generado intensos debates sobre la propiedad intelectual, las libertades del usuario y las formas de creación y distribución de software. Sin embargo, en estos últimos años el debate ha disminuido notablemente ya que ha demostrado ser viable técnica y económicamente, como lo demuestra el hecho de que algunas de las empresas y sistemas más utilizados en la actualidad son o están basados en software libre. El sistema universitario argentino no ha estado libre ni del debate ni de una temprana adopción tanto del software libre como de los principios que dicho software encarna. Sin embargo, existe una carencia en cuanto a asignaturas que cubran tanto los aspectos metodológicos del desarrollo de software libre como los complejos aspectos legales y los siempre cambiantes modelos de negocios. En este trabajo justificamos la importancia de incluir la enseñanza de metodologías de desarrollo de software libre, proponiendo el dictado de un curso de “Ingeniería de software libre” integrado al currículo de la carrera de Ingeniería en Sistemas de Información o afines con el propósito de que los graduados comprendan las particularidades filosóficas, económicas, legales y técnicas de este cambio de paradigma en la ingeniería de software.Sociedad Argentina de Informática e Investigación Operativa (SADIO
    corecore