    Magnetic properties and giant magnetoresistance in melt-spun CoCu alloys

    Full text link
    Magnetic, structural, and transport properties of as quenched and annealed Co10Cu90 samples have been investigated using x¿ray diffraction and a SQUID magnetometer. The largest value of MR change was observed for the as¿quenched sample annealed at 450°C for 30 min. The magnetic and transport properties closely correlate with the microstructure, mainly with Co magnetic particle size and its distribution. For thermal annealing the as quenched samples below 600°C, the Co particle diameters increase from 4.0 to 6.0 nm with a magnetoresistance (MR) drop from 33.0% to 5.0% at 10 K. Comparison with the theory indicates that the interfacial electron spin¿dependent scattering mechanism correlates with GMR for Co particle diameters up to about 6.0 nm

    Magnetic properties and giant magnetoresistance in melt‐spun Co‐Cu alloys

    Get PDF
    Magnetic, structural, and transport properties of as quenched and annealed Co10Cu90 samples have been investigated using x¿ray diffraction and a SQUID magnetometer. The largest value of MR change was observed for the as¿quenched sample annealed at 450°C for 30 min. The magnetic and transport properties closely correlate with the microstructure, mainly with Co magnetic particle size and its distribution. For thermal annealing the as quenched samples below 600°C, the Co particle diameters increase from 4.0 to 6.0 nm with a magnetoresistance (MR) drop from 33.0% to 5.0% at 10 K. Comparison with the theory indicates that the interfacial electron spin¿dependent scattering mechanism correlates with GMR for Co particle diameters up to about 6.0 nm

    International lower limb collaborative (INTELLECT) study: a multicentre, international retrospective audit of lower extremity open fractures

    Get PDF
    Trauma remains a major cause of mortality and disability across the world1, with a higher burden in developing nations2. Open lower extremity injuries are devastating events from a physical3, mental health4, and socioeconomic5 standpoint. The potential sequelae, including risk of chronic infection and amputation, can lead to delayed recovery and major disability6. This international study aimed to describe global disparities, timely intervention, guideline-directed care, and economic aspects of open lower limb injuries

    International Lower Limb Collaborative (INTELLECT) study : a multicentre, international retrospective audit of lower extremity open fractures

    Get PDF

    7th Drug hypersensitivity meeting: part two

    Get PDF
    No abstract availabl

    Seguimiento de las guías españolas para el manejo del asma por el médico de atención primaria: un estudio observacional ambispectivo

    Get PDF
    Objetivo Evaluar el grado de seguimiento de las recomendaciones de las versiones de la Guía española para el manejo del asma (GEMA 2009 y 2015) y su repercusión en el control de la enfermedad. Material y métodos Estudio observacional y ambispectivo realizado entre septiembre del 2015 y abril del 2016, en el que participaron 314 médicos de atención primaria y 2.864 pacientes. Resultados Utilizando datos retrospectivos, 81 de los 314 médicos (25, 8% [IC del 95%, 21, 3 a 30, 9]) comunicaron seguir las recomendaciones de la GEMA 2009. Al inicio del estudio, 88 de los 314 médicos (28, 0% [IC del 95%, 23, 4 a 33, 2]) seguían las recomendaciones de la GEMA 2015. El tener un asma mal controlada (OR 0, 19, IC del 95%, 0, 13 a 0, 28) y presentar un asma persistente grave al inicio del estudio (OR 0, 20, IC del 95%, 0, 12 a 0, 34) se asociaron negativamente con tener un asma bien controlada al final del seguimiento. Por el contrario, el seguimiento de las recomendaciones de la GEMA 2015 se asoció de manera positiva con una mayor posibilidad de que el paciente tuviera un asma bien controlada al final del periodo de seguimiento (OR 1, 70, IC del 95%, 1, 40 a 2, 06). Conclusiones El escaso seguimiento de las guías clínicas para el manejo del asma constituye un problema común entre los médicos de atención primaria. Un seguimiento de estas guías se asocia con un control mejor del asma. Existe la necesidad de actuaciones que puedan mejorar el seguimiento por parte de los médicos de atención primaria de las guías para el manejo del asma. Objective: To assess the degree of compliance with the recommendations of the 2009 and 2015 versions of the Spanish guidelines for managing asthma (Guía Española para el Manejo del Asma [GEMA]) and the effect of this compliance on controlling the disease. Material and methods: We conducted an observational ambispective study between September 2015 and April 2016 in which 314 primary care physicians and 2864 patients participated. Results: Using retrospective data, we found that 81 of the 314 physicians (25.8%; 95% CI 21.3–30.9) stated that they complied with the GEMA2009 recommendations. At the start of the study, 88 of the 314 physicians (28.0%; 95% CI 23.4–33.2) complied with the GEMA2015 recommendations. Poorly controlled asthma (OR, 0.19; 95% CI 0.13–0.28) and persistent severe asthma at the start of the study (OR, 0.20; 95% CI 0.12–0.34) were negatively associated with having well-controlled asthma by the end of the follow-up. In contrast, compliance with the GEMA2015 recommendations was positively associated with a greater likelihood that the patient would have well-controlled asthma by the end of the follow-up (OR, 1.70; 95% CI 1.40–2.06). Conclusions: Low compliance with the clinical guidelines for managing asthma is a common problem among primary care physicians. Compliance with these guidelines is associated with better asthma control. Actions need to be taken to improve primary care physician compliance with the asthma management guidelines

    Textural Characterisation of Iron-Promoted Raney Nickel Catalysts Synthesised by Mechanical Alloying

    No full text
    Mesoporous binary Al x Ni y and ternary Al x Ni y Fe z Raney-type catalysts were synthesised by a two-step procedure involving two main processes, i.e. (i) mechanical metal alloying and (ii) alkaline aluminium leaching. Pure metallic powders of Al, Ni and Fe (if required) were first mechanically alloyed in an attrition mill and then subjected to KOH leaching to selectively remove part of the aluminium atoms. After a slow drying process, a fine, nanostructured slit-shaped material was obtained. Substrate characterisation involved studies by atomic absorption (AA), X-ray diffraction (XRD), scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDXS) in the SEM and nitrogen physisorption. An intermetallic β- or B2-(AlNi) phase with a metastable bcc crystalline structure was formed as a non-equilibrium phase after the metal alloying process. Because of aluminium removal, the β-(AlNi) phase was transformed into the more stable nickel fcc structure. In this work, some important physico-chemical properties of binary (Al–Ni) and ternary (Al–Ni–Fe) catalysts, with especial attention to textural properties adduced from nitrogen physisorption, are presented and discussed

    EBSD characterization of an if steel processed by Accumulative Roll Bonding

    Get PDF
    The objective of this work is to study the texture and microstructure evolution of an IF steel deformed by Accumulative Roll Bonding (ARB) using Electron Backscatter Diffraction. Texture changes occur with increasing number of ARB cycles. For the early cycles, the main components are the α and γ fiber components characteristic of steels. With increasing the number of ARB cycles a tendency towards a random texture is obtained. In the initial state, the mean grain size is 30 μm and after 5 cycles it decreases to 1.2 μm. For the first ARB cycles, the fraction of high angle grain boundary is low but it increases with the number of cycles to about 80% for 5 cycles. The Kernel Average Misorientation (KAM) has no appreciable changes with the number of ARB cycles for all the texture components.Fil: Cruz Gandarilla, F.. Instituto Politécnico Nacional; MéxicoFil: Salcedo Garrido, A. M.. Instituto Politécnico Nacional; MéxicoFil: Avalos, Martina Cecilia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario. Instituto de Física de Rosario. Universidad Nacional de Rosario. Instituto de Física de Rosario; ArgentinaFil: Bolmaro, Raul Eduardo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario. Instituto de Física de Rosario. Universidad Nacional de Rosario. Instituto de Física de Rosario; ArgentinaFil: Baudin, T.. Centre National de la Recherche Scientifique; Francia. Université Paris Sud; FranciaFil: Cabañas Moreno, J. G.. CINVESTAV; MéxicoFil: Dorantes Rosales, H. J.. Instituto Politécnico Nacional; Méxic