129 research outputs found
BTZ-copolymer loaded graphene aerogel as new type Green and metal-freevisible light photocatalyst
This paper reports a new class of efficient, green and metal-free visible-light photocatalyst made from graphene aerogel (GA) doped with a conjugated porous polymer (CMPs). Hence, we report the synthesis of a benzothiadiazole (BTZ)-based CMP loaded into GA via a one-step hydrothermal reaction between 2D graphene oxide (GO) and the CMP, performed through a green process and under mild conditions. The as-prepared GA showed a bathochromic shift in the UV–vis diffraction reflectance spectroscopy (DRS) absorption edge to 628.5 nm, demonstrating its ability to absorb light in the visible region. SEM, TEM, XPS, EDX mapping results further showed the successful loading of the BTZ-based CMP in the GA array. The synthesized GA was used as a 3D structured photocatalyst for the visible-light-driven photodecomposition of methyl orange (MO) with an efficiency of 89.2% (5 wt% CMP). When compared to that of the pure CMP (86.9%), a comparable yet small increase in the efficiency was observed. This is due to a synergistic effect between GO and loaded polymer in GA array upon the formation of CMPGA hybrid structure via chemical interaction between BTZ-Py and GO throughout the mild hydrothermal reaction, and the enhanced photocatalytic activity exhibited from 1 mg equivalent polymer in the CMPGA2 hybrid when compared to the 20 mg pure polymer. Upon repeated use, the depreciation in photocatalytic activity was low with a <5% drop over 3 cycles. These results showed the CMP-loaded GA as an efficient metal-free photocatalyst and a promising material for further investigation into other photocatalytic applications
Impurity and spin effects on the magneto-spectroscopy of a THz-modulated nanostructure
We present a grid-free DFT model appropriate to explore the time evolution of
electronic states in a semiconductor nanostructure. The model can be used to
investigate both the linear and the nonlinear response of the system to an
external short-time perturbation in the THz regime. We use the model to study
the effects of impurities on the magneto-spectroscopy of a two-dimensional
electron gas in a nanostructure excited by an intense THz radiation. We do
observe a reduction in the binding energy of the impurity with increasing
excitation strength, and at a finite magnetic field we find a slow onset of
collective spin-oscillations that can be made to vanish with a stronger
excitation.Comment: LaTeX,10 pages with 11 embedded postscript figure
The combined role of MRI prostate and prostate health index in improving detection of significant prostate cancer in a screening population of Chinese men
Using prostate-specific antigen (PSA) for prostate cancer (PCa) screening led to overinvestigation and overdiagnosis of indolent PCa. We aimed to investigate the value of prostate health index (PHI) and magnetic resonance imaging (MRI) prostate in an Asian PCa screening program. Men aged 50-75 years were prospectively recruited from a community-based PSA screening program. Men with PSA 4.0-10.0 ng ml -1 had PHI result analyzed. MRI prostate was offered to men with PSA 4.0-50.0 ng ml -1. A systematic prostate biopsy was offered to men with PSA 4.0-9.9 ng ml -1 and PHI ≥35, or PSA 10.0-50.0 ng ml -1. Additional targeted prostate biopsy was offered if they had PI-RADS score ≥3. Clinically significant PCa (csPCa) was defined as the International Society of Urological Pathology (ISUP) grade group (GG) ≥2 or ISUP GG 1 with involvement of ≥30% of total systematic cores. In total, 12.8% (196/1536) men had PSA ≥4.0 ng ml -1. Among 194 men with PSA 4.0-50.0 ng ml -1, 187 (96.4%) received MRI prostate. Among them, 28.3% (53/187) had PI-RADS ≥3 lesions. Moreover, 7.0% (107/1536) men were indicated for biopsy and 94.4% (101/107) men received biopsy. Among the men received biopsy, PCa, ISUP GG ≥2 PCa, and csPCa was diagnosed in 42 (41.6%), 24 (23.8%), and 34 (33.7%) men, respectively. Compared with PSA/PHI pathway in men with PSA 4.0-50.0 ng ml -1, additional MRI increased diagnoses of PCa, ISUP GG ≥2 PCa, and csPCa by 21.2% (from 33 to 40), 22.2% (from 18 to 22), and 18.5% (from 27 to 32), respectively. The benefit of additional MRI was only observed in PSA 4.0-10.0 ng ml -1, and the number of MRI needed to diagnose one additional ISUP GG ≥2 PCa was 20 in PHI ≥35 and 94 in PHI <35. Among them, 45.4% (89/196) men with PSA ≥4.0 ng ml -1 avoided unnecessary biopsy with the use of PHI and MRI. A screening algorithm with PSA, PHI, and MRI could effectively diagnose csPCa while reducing unnecessary biopsies. The benefit of MRI prostate was mainly observed in PSA 4.0-9.9 ng ml -1 and PHI ≥35 group. PHI was an important risk stratification step for PCa screening.</p
Multi-material additive manufacturing of low sintering temperature Bi2Mo2O9 ceramics with Ag floating electrodes by selective laser burnout
Additive manufacturing (AM) of co-fired low temperature ceramics offers a unique route for fabrication of novel 3D radio frequency (RF) and microwave communication components, embedded electronics and sensors. This paper describes the first-ever direct 3D printing of low temperature co-fired ceramics/floating electrode 3D structures. Slurry-based AM and selective laser burnout (SLB) were used to fabricate bulk dielectric, Bi2Mo2O9 (BMO, sintering temperature = 620–650°C, εr = 38) with silver (Ag) internal floating electrodes. A printable BMO slurry was developed and the SLB optimised to improve edge definition and burn out the binder without damaging the ceramic. The SLB increased the green strength needed for shape retention, produced crack-free parts and prevented Ag leaching into the ceramic during co-firing. The green parts were sintered after SLB in a conventional furnace at 645°C for 4 h and achieved 94.5% density, compressive strength of 4097 MPa, a relative permittivity (εr) of 33.8 and a loss tangent (tan δ) of 0.0004 (8 GHz) for BMO. The feasibility of using SLB followed by a post-printing sintering step to create BMO/Ag 3D structures was thus demonstrated
Search for the Rare Decays J/Psi --> Ds- e+ nu_e, J/Psi --> D- e+ nu_e, and J/Psi --> D0bar e+ e-
We report on a search for the decays J/Psi --> Ds- e+ nu_e + c.c., J/Psi -->
D- e+ nu_e + c.c., and J/Psi --> D0bar e+ e- + c.c. in a sample of 5.8 * 10^7
J/Psi events collected with the BESII detector at the BEPC. No excess of signal
above background is observed, and 90% confidence level upper limits on the
branching fractions are set: B(J/Psi --> Ds- e+ nu_e + c.c.)<4.8*10^-5, B(J/Psi
--> D- e+ nu_e + c.c.) D0bar e+ e- + c.c.)<1.1*10^-5Comment: 10 pages, 4 figure
Observation of the decay \psip\rar\kstark
Using 14 million events collected with the BESII detector,
branching fractions of \psip\rar\kstarkpm and \kstarknn are determined to
be: \calB(\psip\rar\kstarkpm)=(2.9^{+1.3}_{-1.7}\pm0.4)\times 10^{-5} and
\calB(\psip\rar\kstarknn)=(13.3^{+2.4}_{-2.7}\pm1.9)\times 10^{-5}. The
results confirm the violation of the "12%" rule for these two decay channels
with higher precision. A large isospin violation between the charged and
neutral modes is observed.Comment: 5 pages, 3 figure
Direct Measurements of the Branching Fractions for and and Determinations of the Form Factors and
The absolute branching fractions for the decays and
are determined using singly
tagged sample from the data collected around 3.773 GeV with the
BES-II detector at the BEPC. In the system recoiling against the singly tagged
meson, events for and events for decays are observed. Those yield
the absolute branching fractions to be and . The
vector form factors are determined to be
and . The ratio of the two form
factors is measured to be .Comment: 6 pages, 5 figure
Study of J/psi decays to Lambda Lambdabar and Sigma0 Sigma0bar
The branching ratios and Angular distributions for J/psi decays to Lambda
Lambdabar and Sigma0 Sigma0bar are measured using BESII 58 million J/psi.Comment: 11 pages, 5 figure
- …