131 research outputs found

    Imminent brain death: point of departure for potential heart-beating organ donor recognition

    Get PDF
    Contains fulltext : 88186.pdf (publisher's version ) (Closed access)PURPOSE: There is, in European countries that conduct medical chart review of intensive care unit (ICU) deaths, no consensus on uniform criteria for defining a potential organ donor. Although the term is increasingly being used in recent literature, it is seldom defined in detail. We searched for criteria for determination of imminent brain death, which can be seen as a precursor for organ donation. METHODS: We organized meetings with representatives from the field of clinical neurology, neurotraumatology, intensive care medicine, transplantation medicine, clinical intensive care ethics, and organ procurement management. During these meetings, all possible criteria were discussed to identify a patient with a reasonable probability to become brain dead (imminent brain death). We focused on the practical usefulness of two validated coma scales (Glasgow Coma Scale and the FOUR Score), brain stem reflexes and respiration to define imminent brain death. Further we discussed criteria to determine irreversibility and futility in acute neurological conditions. RESULTS: A patient who fulfills the definition of imminent brain death is a mechanically ventilated deeply comatose patient, admitted to an ICU, with irreversible catastrophic brain damage of known origin. A condition of imminent brain death requires either a Glasgow Coma Score of 3 and the progressive absence of at least three out of six brain stem reflexes or a FOUR score of E(0)M(0)B(0)R(0). CONCLUSION: The definition of imminent brain death can be used as a point of departure for potential heart-beating organ donor recognition on the intensive care unit or retrospective medical chart analysis.1 september 201

    Surgery for scapula process fractures: Good outcome in 26 patients

    Get PDF
    Background Generally, scapula process fractures (coracoid and acromion) have been treated nonoperatively with favorable outcome, with the exception of widely displaced fractures. Very little has been published, however, regarding the operative management of such fractures and the literature that is available involves very few patients. Our hypothesis was that operative treatment of displaced acromion and coracoid fractures is a safe and effective treatment that yields favorable surgical results

    Comparison of the Full Outline of UnResponsiveness and Glasgow Liege Scale/Glasgow Coma Scale in an Intensive Care Unit Population.

    Full text link
    peer reviewedBACKGROUND: The Full Outline of UnResponsiveness (FOUR) has been proposed as an alternative for the Glasgow Coma Scale (GCS)/Glasgow Liege Scale (GLS) in the evaluation of consciousness in severely brain-damaged patients. We compared the FOUR and GLS/GCS in intensive care unit patients who were admitted in a comatose state. METHODS: FOUR and GLS evaluations were performed in randomized order in 176 acutely (<1 month) brain-damaged patients. GLS scores were transformed in GCS scores by removing the GLS brainstem component. Inter-rater agreement was assessed in 20% of the studied population (N = 35). A logistic regression analysis adjusted for age, and etiology was performed to assess the link between the studied scores and the outcome 3 months after injury (N = 136). RESULTS: GLS/GCS verbal component was scored 1 in 146 patients, among these 131 were intubated. We found that the inter-rater reliability was good for the FOUR score, the GLS/GCS. FOUR, GLS/GCS total scores predicted functional outcome with and without adjustment for age and etiology. 71 patients were considered as being in a vegetative/unresponsive state based on the GLS/GCS. The FOUR score identified 8 of these 71 patients as being minimally conscious given that these patients showed visual pursuit. CONCLUSIONS: The FOUR score is a valid tool with good inter-rater reliability that is comparable to the GLS/GCS in predicting outcome. It offers the advantage to be performable in intubated patients and to identify non-verbal signs of consciousness by assessing visual pursuit, and hence minimal signs of consciousness (11% in this study), not assessed by GLS/GCS scales

    Saccadic latency in hepatic encephalopathy: a pilot study

    Get PDF
    Hepatic encephalopathy is a common complication of cirrhosis. The degree of neuro-psychiatric impairment is highly variable and its clinical staging subjective. We investigated whether eye movement response times—saccadic latencies—could serve as an indicator of encephalopathy. We studied the association between saccadic latency, liver function and paper- and pencil tests in 70 patients with cirrhosis and 31 patients after liver transplantation. The tests included the porto-systemic encephalopathy (PSE-) test, critical flicker frequency, MELD score and ammonia concentration. A normal range for saccades was established in 31 control subjects. Clinical and biochemical parameters of liver, blood, and kidney function were also determined. Median saccadic latencies were significantly longer in patients with liver cirrhosis when compared to patients after liver transplantation (244 ms vs. 278 ms p < 0.001). Both patient groups had prolonged saccadic latency when compared to an age matched control group (175 ms). The reciprocal of median saccadic latency (ÎŒ) correlated with PSE tests, MELD score and critical flicker frequency. A significant correlation between the saccadic latency parameter early slope (σE) that represents the prevalence of early saccades and partial pressure of ammonia was also noted. Psychometric test performance, but not saccadic latency, correlated with blood urea and sodium concentrations. Saccadic latency represents an objective and quantitative parameter of hepatic encephalopathy. Unlike psychometric test performance, these ocular responses were unaffected by renal function and can be obtained clinically within a matter of minutes by non-trained personnel

    Origin and insertion of the medial patellofemoral ligament: a systematic review of anatomy.

    Get PDF
    PURPOSE: The medial patellofemoral ligament (MPFL) is the major medial soft-tissue stabiliser of the patella, originating from the medial femoral condyle and inserting onto the medial patella. The exact position reported in the literature varies. Understanding the true anatomical origin and insertion of the MPFL is critical to successful reconstruction. The purpose of this systematic review was to determine these locations. METHODS: A systematic search of published (AMED, CINAHL, MEDLINE, EMBASE, PubMed and Cochrane Library) and unpublished literature databases was conducted from their inception to the 3 February 2016. All papers investigating the anatomy of the MPFL were eligible. Methodological quality was assessed using a modified CASP tool. A narrative analysis approach was adopted to synthesise the findings. RESULTS: After screening and review of 2045 papers, a total of 67 studies investigating the relevant anatomy were included. From this, the origin appears to be from an area rather than (as previously reported) a single point on the medial femoral condyle. The weighted average length was 56 mm with an 'hourglass' shape, fanning out at both ligament ends. CONCLUSION: The MPFL is an hourglass-shaped structure running from a triangular space between the adductor tubercle, medial femoral epicondyle and gastrocnemius tubercle and inserts onto the superomedial aspect of the patella. Awareness of anatomy is critical for assessment, anatomical repair and successful surgical patellar stabilisation. LEVEL OF EVIDENCE: Systematic review of anatomical dissections and imaging studies, Level IV

    The critical care management of poor-grade subarachnoid haemorrhage

    Full text link

    Hyponatremia in the intensive care unit: How to avoid a Zugzwang situation?

    Get PDF

    Anatomic posterolateral knee reconstructions require a popliteofibular ligament reconstruction through a tibial tunnel.

    No full text
    BACKGROUND: No biomechanical study has been performed analyzing the merits of reconstructing the popliteofibular ligament (PFL) through a tibial tunnel with an anatomic reconstruction of the posterolateral knee. HYPOTHESIS: There is no difference in an anatomic posterolateral knee reconstruction with or without a PFL reconstruction placed through a tibial tunnel in restoring knee motion to the intact, uninjured state, and the knee is not overconstrained with this reconstruction. STUDY DESIGN: Controlled laboratory study. METHODS: Eight paired knees were tested in the intact state and then sectioned to simulate a grade III posterolateral knee injury. The reconstruction for the first paired knee reconstructed the PFL (through a tibial tunnel), popliteus tendon, and fibular collateral ligament (group 1); the matched knee reconstruction involved only the popliteus tendon and fibular collateral ligament (group 2). RESULTS: Reconstructions for group 1 knees restored knee motion to the intact state for all tested conditions at all knee flexion angles with no overconstraint of the knee. Without reconstructing the PFL (group 2), small but significant increases in motion were found for varus translation at 0 degrees (3.0 degrees ), 20 degrees (3.1 degrees ), and 60 degrees (3.8 degrees ) of knee flexion compared with the intact state. At 60 degrees and 90 degrees of flexion, the reconstruction for group 2 had small but significant increases in internal rotation compared with the intact state (1.3 degrees and 1.8 degrees , respectively). CONCLUSION: Inclusion of the PFL through a tibial tunnel as part of an anatomic posterolateral knee reconstruction restores knee stability back to the intact state and does not overconstrain the knee. Furthermore, inclusion of the PFL through a tibial tunnel restored normal internal rotation. CLINICAL RELEVANCE: The PFL should be included in anatomic reconstructions of grade III posterolateral knee injuries with placement through a tibial tunnel to best restore the intact, preinjury knee motion state and, most notably, normal internal rotation without evidence of overconstraint of the knee
    • 

    corecore