1,111 research outputs found

    Photometric compliance of tablet screens and retro-illuminated acuity charts as visual acuity measurement devices

    Get PDF
    Mobile technology is increasingly used to measure visual acuity. Standards for chart-based acuity tests specify photometric requirements for luminance, optotype contrast and luminance uniformity. Manufacturers provide some photometric data but little is known about tablet performance for visual acuity testing. This study photometrically characterised seven tablet computers (iPad, Apple inc.) and three ETDRS (Early Treatment Diabetic Retinopathy Study) visual acuity charts with room lights on and off, and compared findings with visual acuity measurement standards. Tablet screen luminance and contrast were measured using nine points across a black and white checkerboard test screen at five arbitrary brightness levels. ETDRS optotypes and adjacent white background luminance and contrast were measured. All seven tablets (room lights off) exceeded the most stringent requirement for mean luminance (≥ 120 cd/m2) providing the nominal brightness setting was above 50%. All exceeded contrast requirement (Weber ≥ 90%) regardless of brightness setting, and five were marginally below the required luminance uniformity threshold (Lmin/Lmax ≥ 80%). Re-assessing three tablets with room lights on made little difference to mean luminance or contrast, and improved luminance uniformity to exceed the threshold. The three EDTRS charts (room lights off) had adequate mean luminance (≥ 120 cd/m2) and Weber contrast (≥ 90%), but all three charts failed to meet the luminance uniformity standard (Lmin/Lmax ≥ 80%). Two charts were operating beyond manufacturer’s recommended lamp replacement schedule. With room lights on, chart mean luminance and Weber contrast increased, but two charts still had inadequate luminance uniformity. Tablet computers showed less inter-device variability, higher contrast, and better luminance uniformity than charts in both lights-on and lights-off environments, providing brightness setting was >50%. Overall, iPad tablets matched or marginally out-performed ETDRS charts in terms of photometric compliance with high contrast acuity standards

    Hidden symmetry of hyperbolic monopole motion

    Get PDF
    Hyperbolic monopole motion is studied for well separated monopoles. It is shown that the motion of a hyperbolic monopole in the presence of one or more fixed monopoles is equivalent to geodesic motion on a particular submanifold of the full moduli space. The metric on this submanifold is found to be a generalisation of the multi-centre Taub-NUT metric introduced by LeBrun. The one centre case is analysed in detail as a special case of a class of systems admitting a conserved Runge-Lenz vector. The two centre problem is also considered. An integrable classical string motion is exhibited.Comment: 39 pages, 7 figures, references added, minor changes to section

    Sex Disparities in Arrest Outcomes for Domestic Violence

    Get PDF
    Domestic violence arrests have been historically focused on protecting women and children from abusive men. Arrest patterns continue to reflect this bias with more men arrested for domestic violence compared to women. Such potential gender variations in arrest patterns pave the way to the investigation of disparities by sex of the offender in domestic violence arrests. This study utilizes data from a quantitative dataset that includes responses by police officers who completed a specially mandated checklist after responding to a domestic dispute. The results showed that while females are arrested quite often in domestic disputes, there remains a significant difference in the arrest outcome whereby male suspects were more likely to be arrested than female suspects. Regression models further indicated differences based on sex and certain predictors of arrest, which supported sex-based rationales in arrests for domestic violence.Yeshttps://us.sagepub.com/en-us/nam/manuscript-submission-guideline

    MODELING OF OZONE DUE TO WEATHER CONDITIONS

    Get PDF
    Ozone concentrations are valuable indicators of possible health and environmental impacts. However, they are also used to monitor changes and trends in the sources of both ozone and its precursors. For this purpose, the influence of meteorological variables is a confusing factor. This study presents an analysis of 4 year of ozone concentrations measured in a Campo Grande-MS-Brazil city. Firstly, the aim of this study was to perceive the daily, monthly and seasonal variation patterns of ozone concentrations. Diurnal cycles are presented by season and the fit of the data to a normal distribution is tested. In order to assess ozone behaviour under weather conditions, local meteorological variables (wind direction and speed, temperature, relative humidity and rainfall) were monitored together with ozone concentrations. The main relationships we could observe in these analyses were then used to obtain a regression equation linking diurnal ozone concentrations with meteorological parameters. The developed model is capable of explaining over 70% of the variability in the ozone concentration

    Evaluation of lasting effects of heat stress on sperm profile and oxidative status of ram semen and epididymal sperm

    Get PDF
    Higher temperatures lead to an increase of testicular metabolism that results in spermatic damage. Oxidative stress is the main factor responsible for testicular damage caused by heat stress. The aim of this study was to evaluate lasting effects of heat stress on ejaculated sperm and immediate or long-term effects of heat stress on epididymal sperm. We observed decrease in motility and mass motility of ejaculated sperm, as well as an increase in the percentages of sperm showing major and minor defects, damaged plasma and acrosome membranes, and a decrease in the percentage of sperm with high mitochondrial membrane potential in the treated group until one spermatic cycle. An increased enzymatic activity of glutathione peroxidase and an increase of stressed cells were observed in ejaculated sperm of the treated group. A decrease in the percentage of epididymal sperm with high mitochondrial membrane potential was observed in the treated group. However, when comparing immediate and long-term effects, we observed an increase in the percentage of sperm with low mitochondrial membrane potential. In conclusion, testicular heat stress induced oxidative stress that led to rescuable alterations after one spermatic cycle in ejaculated sperm and also after 30 days in epididymal sperm

    Extreme endurance flights by landbirds crossing the Pacific Ocean: ecological corridor rather than barrier?

    Get PDF
    Mountain ranges, deserts, ice fields and oceans generally act as barriers to the movement of land-dependent animals, often profoundly shaping migration routes. We used satellite telemetry to track the southward flights of bar-tailed godwits (Limosa lapponica baueri), shorebirds whose breeding and non-breeding areas are separated by the vast central Pacific Ocean. Seven females with surgically implanted transmitters flew non-stop 8117–11 680 km (10 153±1043 s.d.) directly across the Pacific Ocean; two males with external transmitters flew non-stop along the same corridor for 7008–7390 km. Flight duration ranged from 6.0 to 9.4 days (7.8±1.3 s.d.) for birds with implants and 5.0 to 6.6 days for birds with externally attached transmitters. These extraordinary non-stop flights establish new extremes for avian flight performance, have profound implications for understanding the physiological capabilities of vertebrates and how birds navigate, and challenge current physiological paradigms on topics such as sleep, dehydration and phenotypic flexibility. Predicted changes in climatic systems may affect survival rates if weather conditions at their departure hub or along the migration corridor should change. We propose that this transoceanic route may function as an ecological corridor rather than a barrier, providing a wind-assisted passage relatively free of pathogens and predators

    Special fast diffusion with slow asymptotics. Entropy method and flow on a Riemannian manifold

    Full text link
    We consider the asymptotic behaviour of positive solutions u(t,x)u(t,x) of the fast diffusion equation ut=Δ(um/m)=div(um1u)u_t=\Delta (u^{m}/m)={\rm div} (u^{m-1}\nabla u) posed for x\in\RR^d, t>0t>0, with a precise value for the exponent m=(d4)/(d2)m=(d-4)/(d-2). The space dimension is d3d\ge 3 so that m<1m<1, and even m=1m=-1 for d=3d=3. This case had been left open in the general study \cite{BBDGV} since it requires quite different functional analytic methods, due in particular to the absence of a spectral gap for the operator generating the linearized evolution. The linearization of this flow is interpreted here as the heat flow of the Laplace-Beltrami operator of a suitable Riemannian Manifold (\RR^d,{\bf g}), with a metric g{\bf g} which is conformal to the standard \RR^d metric. Studying the pointwise heat kernel behaviour allows to prove {suitable Gagliardo-Nirenberg} inequalities associated to the generator. Such inequalities in turn allow to study the nonlinear evolution as well, and to determine its asymptotics, which is identical to the one satisfied by the linearization. In terms of the rescaled representation, which is a nonlinear Fokker--Planck equation, the convergence rate turns out to be polynomial in time. This result is in contrast with the known exponential decay of such representation for all other values of mm.Comment: 37 page

    An Intact Kidney Slice Model to Investigate Vasa Recta Properties and Function in situ

    Get PDF
    Background: Medullary blood flow is via vasa recta capillaries, which possess contractile pericytes. In vitro studies using isolated descending vasa recta show that pericytes can constrict/dilate descending vasa recta when vasoactive substances are present. We describe a live kidney slice model in which pericyte-mediated vasa recta constriction/dilation can be visualized in situ. Methods: Confocal microscopy was used to image calcein, propidium iodide and Hoechst labelling in ‘live’ kidney slices, to determine tubular and vascular cell viability and morphology. DIC video-imaging of live kidney slices was employed to investigate pericyte-mediated real-time changes in vasa recta diameter. Results: Pericytes were identified on vasa recta and their morphology and density were characterized in the medulla. Pericyte-mediated changes in vasa recta diameter (10–30%) were evoked in response to bath application of vasoactive agents (norepinephrine, endothelin-1, angiotensin-II and prostaglandin E2) or by manipulating endogenous vasoactive signalling pathways (using tyramine, L-NAME, a cyclo-oxygenase (COX-1) inhibitor indomethacin, and ATP release). Conclusions: The live kidney slice model is a valid complementary technique for investigating vasa recta function in situ and the role of pericytes as regulators of vasa recta diameter. This technique may also be useful in exploring the role of tubulovascular crosstalk in regulation of medullary blood flow

    Light cluster production in intermediate energy heavy-ion collisions induced by neutron-rich nuclei

    Full text link
    The coalescence model based on nucleon distribution functions from an isospin-dependent transport model is used to study the production of light clusters such as deuteron, triton, and 3^{3}He from heavy-ion collisions induced by neutron-rich nuclei at intermediate energies. It is found that the emission time of light clusters depends on their masses. For clusters with the same momentum per nucleon, heavier ones are emitted earlier. Both the yield and energy spectrum of light clusters are sensitive to the density dependence of nuclear symmetry energy, with more light clusters produced in the case of a stiff symmetry energy. On the other hand, effects due to the stiffness of the isoscalar part of nuclear equation of state and the medium dependence of nucleon-nucleon cross sections on light cluster production are unimportant. We have also studied the correlation functions of clusters, and they are affected by the density dependence of nuclear symmetry energy as well, with the stiff symmetry energy giving a stronger anti-correlation of light clusters, particularly for those with large kinetic energies. Dependence of light cluster production on the centrality and incident energy of heavy ion collisions as well as the mass of the reaction system is also investigated.Comment: Revised version, typos corrected and discussions added, 14 pages, 15 figures, 1 table, REVTeX4.

    Fast automated cell phenotype image classification

    Get PDF
    BACKGROUND: The genomic revolution has led to rapid growth in sequencing of genes and proteins, and attention is now turning to the function of the encoded proteins. In this respect, microscope imaging of a protein's sub-cellular localisation is proving invaluable, and recent advances in automated fluorescent microscopy allow protein localisations to be imaged in high throughput. Hence there is a need for large scale automated computational techniques to efficiently quantify, distinguish and classify sub-cellular images. While image statistics have proved highly successful in distinguishing localisation, commonly used measures suffer from being relatively slow to compute, and often require cells to be individually selected from experimental images, thus limiting both throughput and the range of potential applications. Here we introduce threshold adjacency statistics, the essence which is to threshold the image and to count the number of above threshold pixels with a given number of above threshold pixels adjacent. These novel measures are shown to distinguish and classify images of distinct sub-cellular localization with high speed and accuracy without image cropping. RESULTS: Threshold adjacency statistics are applied to classification of protein sub-cellular localization images. They are tested on two image sets (available for download), one for which fluorescently tagged proteins are endogenously expressed in 10 sub-cellular locations, and another for which proteins are transfected into 11 locations. For each image set, a support vector machine was trained and tested. Classification accuracies of 94.4% and 86.6% are obtained on the endogenous and transfected sets, respectively. Threshold adjacency statistics are found to provide comparable or higher accuracy than other commonly used statistics while being an order of magnitude faster to calculate. Further, threshold adjacency statistics in combination with Haralick measures give accuracies of 98.2% and 93.2% on the endogenous and transfected sets, respectively. CONCLUSION: Threshold adjacency statistics have the potential to greatly extend the scale and range of applications of image statistics in computational image analysis. They remove the need for cropping of individual cells from images, and are an order of magnitude faster to calculate than other commonly used statistics while providing comparable or better classification accuracy, both essential requirements for application to large-scale approaches
    corecore