14 research outputs found

    Gadoxetate-enhanced abbreviated MRI is highly accurate for hepatocellular carcinoma screening.

    Get PDF
    The primary objective was to compare the performance of 3 different abbreviated MRI (AMRI) sets extracted from a complete gadoxetate-enhanced MRI obtained for hepatocellular carcinoma (HCC) screening. Secondary objective was to perform a preliminary cost-effectiveness analysis, comparing each AMRI set to published ultrasound performance for HCC screening in the USA. This retrospective study included 237 consecutive patients (M/F, 146/91; mean age, 58 years) with chronic liver disease who underwent a complete gadoxetate-enhanced MRI for HCC screening in 2017 in a single institution. Two radiologists independently reviewed 3 AMRI sets extracted from the complete exam: non-contrast (NC-AMRI: T2-weighted imaging (T2wi)+diffusion-weighted imaging (DWI)), dynamic-AMRI (Dyn-AMRI: T2wi+DWI+dynamic T1wi), and hepatobiliary phase AMRI (HBP-AMRI: T2wi+DWI+T1wi during the HBP). Each patient was classified as HCC-positive/HCC-negative based on the reference standard, which consisted in all available patient data. Diagnostic performance for HCC detection was compared between sets. Estimated set characteristics, including historical ultrasound data, were incorporated into a microsimulation model for cost-effectiveness analysis. The reference standard identified 13/237 patients with HCC (prevalence, 5.5%; mean size, 33.7 ± 30 mm). Pooled sensitivities were 61.5% for NC-AMRI (95% confidence intervals, 34.4-83%), 84.6% for Dyn-AMRI (60.8-95.1%), and 80.8% for HBP-AMRI (53.6-93.9%), without difference between sets (p range, 0.06-0.16). Pooled specificities were 95.5% (92.4-97.4%), 99.8% (98.4-100%), and 94.9% (91.6-96.9%), respectively, with a significant difference between Dyn-AMRI and the other sets (p < 0.01). All AMRI methods were effective compared with ultrasound, with life-year gain of 3-12 months against incremental costs of US$ < 12,000. NC-AMRI has limited sensitivity for HCC detection, while HBP-AMRI and Dyn-AMRI showed excellent sensitivity and specificity, the latter being slightly higher for Dyn-AMRI. Cost-effectiveness estimates showed that AMRI is effective compared with ultrasound. • Comparison of different abbreviated MRI (AMRI) sets reconstructed from a complete gadoxetate MRI demonstrated that non-contrast AMRI has low sensitivity (61.5%) compared with contrast-enhanced AMRI (80.8% for hepatobiliary phase AMRI and 84.6% for dynamic AMRI), with all sets having high specificity. • Non-contrast and hepatobiliary phase AMRI can be performed in less than 14 min (including set-up time), while dynamic AMRI can be performed in less than 17 min. • All AMRI sets were cost-effective for HCC screening in at-risk population in comparison with ultrasound

    The angular distribution of the reaction νˉe+pe++n\bar{\nu}_e + p \to e^+ + n

    Get PDF
    The reaction νˉe+pe++n\bar{\nu}_e + p \to e^+ + n is very important for low-energy (Eν60E_\nu \lesssim 60 MeV) antineutrino experiments. In this paper we calculate the positron angular distribution, which at low energies is slightly backward. We show that weak magnetism and recoil corrections have a large effect on the angular distribution, making it isotropic at about 15 MeV and slightly forward at higher energies. We also show that the behavior of the cross section and the angular distribution can be well-understood analytically for Eν60E_\nu \lesssim 60 MeV by calculating to O(1/M){\cal O}(1/M), where MM is the nucleon mass. The correct angular distribution is useful for separating νˉe+pe++n\bar{\nu}_e + p \to e^+ + n events from other reactions and detector backgrounds, as well as for possible localization of the source (e.g., a supernova) direction. We comment on how similar corrections appear for the lepton angular distributions in the deuteron breakup reactions νˉe+de++n+n\bar{\nu}_e + d \to e^+ + n + n and νe+de+p+p\nu_e + d \to e^- + p + p. Finally, in the reaction νˉe+pe++n\bar{\nu}_e + p \to e^+ + n, the angular distribution of the outgoing neutrons is strongly forward-peaked, leading to a measurable separation in positron and neutron detection points, also potentially useful for rejecting backgrounds or locating the source direction.Comment: 10 pages, including 5 figure

    Prospects for e+e- physics at Frascati between the phi and the psi

    Get PDF
    We present a detailed study, done in the framework of the INFN 2006 Roadmap, of the prospects for e+e- physics at the Frascati National Laboratories. The physics case for an e+e- collider running at high luminosity at the phi resonance energy and also reaching a maximum center of mass energy of 2.5 GeV is discussed, together with the specific aspects of a very high luminosity tau-charm factory. Subjects connected to Kaon decay physics are not discussed here, being part of another INFN Roadmap working group. The significance of the project and the impact on INFN are also discussed. All the documentation related to the activities of the working group can be found in http://www.roma1.infn.it/people/bini/roadmap.html.Comment: INFN Roadmap Report: 86 pages, 25 figures, 9 table

    Gadoxetate-enhanced Abbreviated MRI for Hepatocellular Carcinoma Surveillance: Preliminary Experience.

    No full text
    To describe a single-center preliminary experience with gadoxetate disodium-enhanced abbreviated MRI for hepatocellular carcinoma (HCC) screening and surveillance in patients with cirrhosis or chronic hepatitis B virus (cHBV). This was a retrospective study of consecutive patients aged 18 years and older with cirrhosis or cHBV who underwent at least one gadoxetate-enhanced abbreviated MRI examination for HCC surveillance from 2014 through 2016. Examinations were interpreted prospectively by one of six abdominal radiologists for clinical care. Clinical, imaging, and other data were extracted from electronic medical records. Diagnostic adequacy was assessed in all patients. Diagnostic accuracy was assessed in the subset of patients who could be classified as having HCC or not having HCC on the basis of a composite reference standard. In this study, 330 patients (93% with cirrhosis; 45% women; mean age, 59 years) underwent gadoxetate-enhanced abbreviated MRI. In the 330 patients, 311 (94.2%) baseline gadoxetate-enhanced abbreviated MRI examinations were diagnostically adequate. Of 141 (43%) of the 330 patients, 91.4% (129 of 141) could be classified as not having HCC and 8.6% (12 of 141) could be classified as having HCC. Baseline gadoxetate-enhanced abbreviated MRI had 0.92 sensitivity (95% confidence interval [CI]: 0.62, 1.00) and 0.91 specificity (95% CI: 0.84, 0.95) for detection of HCC. Of the 330 patients who underwent baseline gadoxetate-enhanced abbreviated MRI, 187 (57%) were lost to follow-up. Gadoxetate-enhanced abbreviated MRI is feasible clinically, has a high diagnostic adequacy rate, and, on the basis of our preliminary experience, accurately depicts HCC in high-risk patients. Strategies to enhance follow-up compliance are needed.© RSNA, 2019Keywords: Abdomen/GI, Cirrhosis, Liver, MR-Imaging, Oncology, ScreeningSupplemental material is available for this article

    Hepatocellular carcinoma detection in liver cirrhosis: diagnostic performance of contrast-enhanced CT vs. MRI with extracellular contrast vs. gadoxetic acid.

    No full text
    To evaluate the diagnostic performance of contrast-enhanced CT vs. MRI with extracellular contrast agents (EC-MRI) vs. MRI with gadoxetic acid (EOB-MRI) for HCC detection in patients with liver cirrhosis using liver explant as the reference. The additional value of hepatobiliary phase (HBP) post Gadoxetic acid was also assessed. Two-hundred seventy-seven consecutive patients who underwent liver transplantation over a 9 year period and imaging within 90 days of were retrospectively included. Imaging consisted in CT (n = 100), EC-MRI (n = 77) and EOB-MRI (n = 100), the latter subdivided into dynamic EOB-MRI and full EOB-MRI (dynamic+HBP). Three radiologists retrospectively categorized lesions ≥ 1 cm using the LI-RADSv2017 algorithm. Dynamic EOB-MRI was re-evaluated with the addition of HBP. Results were correlated with explant pathology. Pathology demonstrated 265 HCCs (mean size 2.1 ± 1.4 cm) in 177 patients. Per-patient sensitivities were 86.3% for CT, 89.5% for EC-MRI, 92.8% for dynamic EOB-MRI and 95.2% for full EOB-MRI (pooled reader data), with a significant difference between CT and dynamic/full EOB-MRI (p = 0.032/0.002), and between EC-MRI and full EOB-MRI (p = 0.047). Per-lesion sensitivities for CT, EC-MRI, dynamic EOB-MRI and full EOB-MRI were 59.5%,78.5%,69.7% and 76.8%, respectively, with a significant difference between MRI groups and CT (p-range:0.001-0.04), and no difference between EC-MRI and dynamic EOB-MRI (p = 0.949). For HCCs 1-1.9 cm, sensitivities were 34.4%, 64.6%, 57.3% and 67.3%, respectively, with all MRI groups significantly superior to CT (p ≤ 0.01) and full EOB-MRI superior to dynamic EOB-MRI (p = 0.002). EOB-MRI outperforms CT and EC-MRI for per-patient HCC detection sensitivity, and is equivalent to EC-MRI for per-lesion sensitivity. MRI methods outperform CT for detection of HCCs 1-1.9 cm. • MRI is superior to CT for HCC detection in patients with liver cirrhosis. • EOB-MRI outperforms CT and MRI using extracellular contrast agents (EC-MRI) for per-patient HCC detection sensitivity, and is equivalent to EC-MRI for per-lesion sensitivity. • The addition of hepatobiliary phase images improves HCC detection when using gadoxetic acid

    Hepatocellular carcinoma detection: diagnostic performance of a simulated abbreviated MRI protocol combining diffusion-weighted and T1-weighted imaging at the delayed phase post gadoxetic acid

    No full text
    Purpose: The purpose of this study was to evaluate the diagnostic performance of a \u201csimulated\u201d abbreviated MRI (AMRI) protocol using diffusion-weighted imaging (DWI) and T1-weighted (T1w) imaging obtained at the hepatobiliary phase (HBP) post gadoxetic acid injection alone and in combination, compared to dynamic contrast-enhanced (CE)-T1w imaging for the detection of hepatocellular carcinoma (HCC). Methods: This was an IRB approved HIPAA compliant retrospective single institution study including patients with liver disease who underwent gadoxetic acid-enhanced MRI for HCC diagnosis. Three independent observers assessed 2 sets of images (full CE-set and AMRI including DWI+T1w-HBP). Diagnostic performance of T1w-HBP and DWI alone and in combination was compared to that of CE-set. All imaging sets included unenhanced T1w and T2w sequences. A preliminary analysis was performed to assess cost savings of AMRI protocol compared to a full MRI study. Results: 174 patients including 62 with 80 HCCs were assessed. Equivalent per-patient sensitivity and negative predictive value (NPV) were observed for DWI (85.5% and 92.2%, pooled data) and T1w-HBP (89.8% and 94.2%) (P\ua0=\ua00.1\u20130.7), while these were significantly lower for the full AMRI protocol (DWI+T1w-HBP, 80.6% and 80%, P\ua0=\ua00.02) when compared to CE-set (90.3% and 94.9%). Higher specificity and positive predictive value were observed for CE-set vs. AMRI (P\ua0=\ua00.02). The estimated cost reduction of AMRI versus full MRI ranged between 30.7 and 49.0%. Conclusion: AMRI using DWI and T1w-HBP has a clinically acceptable sensitivity and NPV for HCC detection. This could serve as the basis for a future study assessing AMRI for HCC screening and surveillance. \ua9 2016, Springer Science+Business Media New York

    Interreader reliability of LI-RADS version 2014 algorithm and imaging features for diagnosis of hepatocellular carcinoma: A large international multireader study

    No full text
    Purpose: To determine in a large multicenter multireader setting the interreader reliability of Liver Imaging Reporting and Data System (LI-RADS) version 2014 categories, the major imaging features seen with computed tomography (CT) and magnetic resonance (MR) imaging, and the potential effect of reader demographics on agreement with a preselected nonconsecutive image set. Materials and Methods: Institutional review board approval was obtained, and patient consent was waived for this retrospective study. Ten image sets, comprising 38-40 unique studies (equal number of CT and MR imaging studies, uniformly distributed LI-RADS categories), were randomly allocated to readers. Images were acquired in unenhanced and standard contrast material-enhanced phases, with observation diameter and growth data provided. Readers completed a demographic survey, assigned LI-RADS version 2014 categories, and assessed major features. Intraclass correlation coefficient (ICC) assessed with mixed-model regression analyses was the metric for interreader reliability of assigning categories and major features. Results: A total of 113 readers evaluated 380 image sets. ICC of final LI-RADS category assignment was 0.67 (95% confidence interval [CI]: 0.61, 0.71) for CT and 0.73 (95% CI: 0.68, 0.77) for MR imaging. ICC was 0.87 (95% CI: 0.84, 0.90) for arterial phase hyperenhancement, 0.85 (95% CI: 0.81, 0.88) for washout appearance, and 0.84 (95% CI: 0.80, 0.87) for capsule appearance. ICC was not significantly affected by liver expertise, LI-RADS familiarity, or years of postresidency practice (ICC range, 0.69-0.70; ICC difference, 0.003-0.01 [95% CI: 20.003 to 20.01, 0.004-0.02]. ICC was borderline higher for private practice readers than for academic readers (ICC difference, 0.009; 95% CI: 0.000, 0.021). Conclusion: ICC is good for final LI-RADS categorization and high for major feature characterization, with minimal reader demographic effect. Of note, our results using selected image sets from nonconsecutive examinations are not necessarily comparable with those of prior studies that used consecutive examination series
    corecore