81 research outputs found

    The quest for equivalence of test results: the pilgrimage of the Dutch Calibration 2.000 program for metrological traceability

    Get PDF
    Afdeling Klinische Chemie en Laboratoriumgeneeskunde (AKCL

    Discordance in glycemic categories and regression to normality at baseline in 10,000 people in a Type 2 diabetes prevention trial

    Get PDF
    The world diabetes population quadrupled between 1980 and 2014 to 422 million and the enormous impact of Type 2 diabetes is recognised by the recent creation of national Type 2 diabetes prevention programmes. There is uncertainty about how to correctly risk stratify people for entry into prevention programmes, how combinations of multiple ‘at high risk’ glycemic categories predict outcome, and how the large recently defined ‘at risk’ population based on an elevated glycosylated haemoglobin (HbA1c) should be managed. We identified all 141,973 people at highest risk of diabetes in our population, and screened 10,000 of these with paired fasting plasma glucose and HbA1c for randomisation into a very large Type 2 diabetes prevention trial. Baseline discordance rate between highest risk categories was 45.6 %, and 21.3 - 37.0 % of highest risk glycaemic categories regressed to normality between paired baseline measurements (median 40 days apart). Accurate risk stratification using both fasting plasma glucose and HbA1c data, the use of paired baseline data, and awareness of diagnostic imprecision at diagnostic thresholds would avoid substantial overestimation of the true risk of Type 2 diabetes and the potential benefits (or otherwise) of intervention, in high risk subjects entering prevention trials and programmes

    IFCC Working Group Recommendations for Assessing Commutability Part 3 : Using the Calibration Effectiveness of a Reference Material

    Get PDF
    A process is described to assess the commutability of a reference material (RM) intended for use as a calibrator based on its ability to fulfill its intended use in a calibration traceability scheme to produce equivalent clinical sample (CS) results among different measurement procedures (MPs) for the same measurand. Three sources of systematic error are elucidated in the context of creating the calibration model for translating MP signals to measurand amounts: calibration fit, calibrator level trueness, and commutability. An example set of 40 CS results from 7 MPs is used to illustrate estimation of bias and variability for each MP. The candidate RM is then used to recalibrate each MP, and its effectiveness in reducing the systematic error among the MPs within an acceptable level of equivalence based on medical requirements confirms its commutability for those MPs. The RM is declared noncommutable for MPs for which, after recalibration, the CS results do not agree with those from other MPs. When a lack of agreement is found, other potential causes, including lack of calibration fit, should be investigated before concluding the RM is noncommutable. The RM is considered fit for purpose for those MPs where commutability is demonstrate

    Investigation of 2 Models to Set and Evaluate Quality Targets for Hb A1c: Biological Variation and Sigma-Metrics

    Get PDF
    BACKGROUND: A major objective of the IFCC Task Force on Implementation of HbA1c Standardization is to develop a model to define quality targets for glycated hemoglobin (Hb A1c). METHODS: Two generic models, biological variation and sigma-metrics, are investigated. We selected variables in the models for Hb A1c and used data of external quality assurance/proficiency testing programs to evaluate the suitability of the models to set and evaluate quality targets within and between laboratories. RESULTS: In the biological variation model, 48% of individual laboratories and none of the 26 instrument groups met the minimum performance criterion. In the sigma-metrics model, with a total allowable error (TAE) set at 5 mmol/mol (0.46% NGSP), 77% of the individual laboratories and 12 of 26 instrument groups met the 2σ criterion. CONCLUSIONS: The biological variation and sigma-metrics models were demonstrated to be suitable for setting and evaluating quality targets within and between laboratories. The sigma-metrics model is more flexible, as both the TAE and the risk of failure can be adjusted to the situation—for example, requirements related to diagnosis/monitoring or international authorities. With the aim of reaching (inter)national consensus on advice regarding quality targets for Hb A1c, the Task Force suggests the sigma-metrics model as the model of choice, with default values of 5 mmol/mol (0.46%) for TAE and risk levels of 2σ and 4σ for routine laboratories and laboratories performing clinical trials, respectively. These goals should serve as a starting point for discussion with international stakeholders in the field of diabetes

    Magnetic Resonance-Guided Stereotactic Body Radiotherapy of Liver Tumors: Initial Clinical Experience and Patient-Reported Outcomes

    Get PDF
    Purpose/ObjectiveStereotactic body radiation therapy (SBRT) has emerged as a valid treatment alternative for non-resectable liver metastases or hepatocellular carcinomas (HCC). Magnetic resonance (MR) guided SBRT has a high potential of further improving treatment quality, allowing for higher, tumoricidal irradiation doses whilst simultaneously sparing organs at risk. However, data on treatment outcome and patient acceptance is still limited.Material/MethodsWe performed a subgroup analysis of an ongoing prospective observational study comprising patients with liver metastases or HCC. Patients were treated with ablative MR-guided SBRT at the MRIdian Linac in the Department of Radiation Oncology at Heidelberg University Hospital between January 2019 and February 2020. Local control (LC) and overall survival (OS) analysis was performed using the Kaplan–Meier method. An in-house designed patient-reported outcome questionnaire was used to measure patients’ experience with the MR-Linac treatment. Toxicity was evaluated using the Common Terminology Criteria for Adverse Events (CTCAE v. 5.0).ResultsTwenty patients (with n = 18 metastases; n = 2 HCC) received MR-guided SBRT for in total 26 malignant liver lesions. Median biologically effective dose (BED at α/β = 10) was 105.0 Gy (range: 67.2–112.5 Gy) and median planning target volume was 57.20 ml (range: 17.4–445.0 ml). Median treatment time was 39.0 min (range: 26.0–67.0 min). At 1-year, LC was 88.1% and OS was 84.0%. Grade I° gastrointestinal toxicity °occurred in 30.0% and grade II° in 5.0% of the patients with no grade III° or higher toxicity. Overall treatment experience was rated positively, with items scoring MR-Linac staff’s performance and items concerning the breath hold process being among the top positively rated elements. Worst scored items were treatment duration, positioning and low temperature.ConclusionMR-guided SBRT of liver tumors is a well-tolerated and well-accepted treatment modality. Initial results are promising with excellent local control and only mildest toxicity. However, prospective studies are warranted to truly assess the potential of MR-guided liver SBRT and to identify which patients profit most from this new versatile technology

    EurA1c: the European HbA1c Trial to Investigate the Performance of HbA1c Assays in 2166 Laboratories across 17 Countries and 24 Manufacturers by Use of the IFCC Model for Quality Targets

    Get PDF
    Background: A major objective of the IFCC Committee on Education and Use of Biomarkers in Diabetes is to generate awareness and improvement of HbA1c assays through evaluation of the performance by countries and manufacturers. Methods: Fresh whole blood and lyophilized hemolysate specimens manufactured from the same pool were used by 17 external quality assessment organizers to evaluate analytical performance of 2166 laboratories. Results were evaluated per country, per manufacturer, and per manufacturer and country combined according to criteria of the IFCC model for quality targets. Results: At the country level with fresh whole blood specimens, 6 countries met the IFCC criterion, 2 did not, and 2 were borderline. With lyophilized hemolysates, 5 countries met the criterion, 2 did not, and 3 were borderline. At the manufacturer level using fresh whole blood specimens, 13 manufacturers met the criterion, 8 did not, and 3 were borderline. Using lyophilized hemolysates, 7 manufacturers met the criterion, 6 did not, and 3 were borderline. In both country and manufacturer groups, the major contribution to total error derived from between-laboratory variation. There were no substantial differences in performance between groups using fresh whole blood or lyophilized hemolysate samples. Conclusions: The state of the art is that 1 of 20 laboratories does not meet the IFCC criterion, but there are substantial differences between country and between manufacturer groups. Efforts to further improve quality should focus on reducing between-laboratory variation. With some limitations, fresh whole blood and well-defined lyophilized specimens are suitable for purpose

    Bilirubin Standardization in the Netherlands: Alignment within and between Manufacturers