110 research outputs found

    Treatment Discontinuation Patterns for Patients With Chronic Lymphocytic Leukemia in Real-World Settings: Results From a Multi-Center International Study

    Get PDF
    Introduction: This study assessed treatment discontinuation patterns and reasons among chronic lymphocytic leukemia (CLL) patients initiating first-line (1L) and second-line (2L) treatments in real-world settings. Materials and / Methods: Using deidentified electronic medical records from the CLL Collaborative Study of Real-World Evidence, premature treatment discontinuation was assessed among FCR, BR, BTKi-based, and BCL-2-based regimen cohorts. / Results: Of 1364 1L patients (initiated in 1997-2021), 190/13.9% received FCR (23.7% discontinued prematurely); 255/18.7% received BR (34.5% discontinued prematurely); 473/34.7% received BTKi-based regimens, of whom 28.1% discontinued prematurely; and 43/3.2% received venetoclax-based regimens, of whom 16.3% discontinued prematurely (venetoclax monotherapy: 7/0.5%, of whom 42.9% discontinued; VG/VR: 36/2.6%, of whom 11.1% discontinued). The most common reasons for treatment discontinuation were adverse events (FCR: 25/13.2%; BR: 36/14.1%; BTKi-based regimens: 75/15.9%) and disease progression (venetoclax-based: 3/7.0%). Of 626 2L patients, 20/3.2% received FCR (50.0% discontinued); 62/9.9% received BR (35.5% discontinued); 303/48.4% received BTKi-based regimens, of whom 38.0% discontinued; and 73/11.7% received venetoclax-based regimens, of whom 30.1% discontinued (venetoclax monotherapy: 27/4.3%, of whom 29.6% discontinued; VG/VR: 43/6.9%, of whom 27.9% discontinued). The most common reasons for treatment discontinuation were adverse events (FCR: 6/30.0%; BR: 11/17.7%; BTKi-based regimens: 60/19.8%; venetoclax-based: 6/8.2%). / Conclusion: The findings of this study highlight the continued need for tolerable therapies in CLL, with finite therapy offering a better tolerated option for patients who are newly diagnosed or relapsed/refractory to prior treatments

    Efficacy of bendamustine and rituximab in unfit patients with previously untreated chronic lymphocytic leukemia. Indirect comparison with ibrutinib in a real-world setting. A GIMEMA-ERIC and US study

    Get PDF
    Limited information is available on the efficacy of front-line bendamustine and rituximab (BR) in chronic lymphocytic leukemia (CLL) with reduced renal function or coexisting conditions. We therefore analyzed a cohort of real-world patients and performed a matched adjusted indirect comparison with a cohort of patients treated with ibrutinib. One hundred and fifty-seven patients with creatinine clearance (CrCl) 6 were treated with BR. The median age was 72 years; 69% of patients had ≥2 comorbidities and the median CrCl was 59.8 mL/min. 17.6% of patients carried TP53 disruption. The median progression-free survival (PFS) was 45 months; TP53 disruption was associated with a shorter PFS (P = 0.05). The overall survival (OS) at 12, 24, and 36 months was 96.2%, 90.1%, and 79.5%, respectively. TP53 disruption was associated with an increased risk of death (P = 0.01). Data on 162 patients ≥65 years treated with ibrutinib were analyzed and compared with 165 patients ≥65 years treated with BR. Factors predicting for a longer PFS at multivariable analysis in the total patient population treated with BR and ibrutinib were age (HR 1.06, 95% CI 1.02-1.10, P < 0.01) and treatment with ibrutinib (HR 0.55, 95% CI 0.33-0.93, P = 0.03). In a post hoc analysis of patients in advanced stage, a significant PFS advantage was observed in patient who had received ibrutinib (P = 0.03), who showed a trend for OS advantage (P = 0.08). We arrived at the following conclusions: (a) BR is a relatively effective first-line regimen in a real-world population of unfit patients without TP53 disruption, (b) ibrutinib provided longer disease control than BR in patients with advanced disease stage

    A retrospective comparison of venetoclax alone or in combination with an anti-CD20 monoclonal antibody in R/R CLL

    Get PDF
    Venetoclax (VEN) is approved for relapsed/refractory (R/R) chronic lymphocytic leukemia (CLL) as monotherapy (VENmono) or in combination with rituximab. Whether VEN plus anti-CD20 (VENcombo) is superior to VENmono is unknown. We conducted a multicenter, retrospective cohort analysis comparing 321 CLL patients treated with VENmono vs VENcombo across the United States and the United Kingdom. We examined demographics, baseline characteristics, dosing, adverse events, response rates, and outcomes. The primary endpoints were progression-free survival (PFS) and overall survival (OS), estimated by Kaplan-Meier method, in patients treated with VENmono vs VENcombo. Univariate and bivariate analyses were performed with COX regression. Three hundred twenty-one CLL patients were included (3 median prior treatments, 78% prior ibrutinib). The overall response rates (ORRs) were similar (VENmono, 81% ORR, 34% complete remission [CR] vs VENcombo, 84% ORR, 32% CR). With a median follow-up of 13.4 months, no differences in PFS and OS were observed between the groups. In unadjusted analyses, the hazard ratios (HRs) for PFS and OS for VENmono vs VENcombo were HR 1.0 (95% confidence interval [CI], 0.6-1.8; P = .7) and HR 1.2 (95% CI, 0.6-2.3; P = .5), respectively. When adjusting for differences between the cohorts, the addition of an anti-CD20 antibody in combination with VEN did not impact PFS (HR, 1.0; 95% CI, 0.5-2.0; P = .9) or OS (HR, 1.1; 95% CI, 0.4-2.6; P = .8). We demonstrate comparable efficacy between VENmono and VENcombo in a heavily pretreated, high-risk, retrospective cohort, in terms of both response data and survival outcomes. Prospective studies are needed to validate these findings

    Combined fit to the spectrum and composition data measured by the Pierre Auger Observatory including magnetic horizon effects

    Get PDF
    The measurements by the Pierre Auger Observatory of the energy spectrum and mass composition of cosmic rays can be interpreted assuming the presence of two extragalactic source populations, one dominating the flux at energies above a few EeV and the other below. To fit the data ignoring magnetic field effects, the high-energy population needs to accelerate a mixture of nuclei with very hard spectra, at odds with the approximate E2^{-2} shape expected from diffusive shock acceleration. The presence of turbulent extragalactic magnetic fields in the region between the closest sources and the Earth can significantly modify the observed CR spectrum with respect to that emitted by the sources, reducing the flux of low-rigidity particles that reach the Earth. We here take into account this magnetic horizon effect in the combined fit of the spectrum and shower depth distributions, exploring the possibility that a spectrum for the high-energy population sources with a shape closer to E2^{-2} be able to explain the observations

    Studies of the mass composition of cosmic rays and proton-proton interaction cross-sections at ultra-high energies with the Pierre Auger Observatory

    Get PDF
    In this work, we present an estimate of the cosmic-ray mass composition from the distributions of the depth of the shower maximum (Xmax) measured by the fluorescence detector of the Pierre Auger Observatory. We discuss the sensitivity of the mass composition measurements to the uncertainties in the properties of the hadronic interactions, particularly in the predictions of the particle interaction cross-sections. For this purpose, we adjust the fractions of cosmic-ray mass groups to fit the data with Xmax distributions from air shower simulations. We modify the proton-proton cross-sections at ultra-high energies, and the corresponding air shower simulations with rescaled nucleus-air cross-sections are obtained via Glauber theory. We compare the energy-dependent composition of ultra-high-energy cosmic rays obtained for the different extrapolations of the proton-proton cross-sections from low-energy accelerator data

    Study of downward Terrestrial Gamma-ray Flashes with the surface detector of the Pierre Auger Observatory

    Get PDF
    The surface detector (SD) of the Pierre Auger Observatory, consisting of 1660 water-Cherenkov detectors (WCDs), covers 3000 km2 in the Argentinian pampa. Thanks to the high efficiency of WCDs in detecting gamma rays, it represents a unique instrument for studying downward Terrestrial Gamma-ray Flashes (TGFs) over a large area. Peculiar events, likely related to downward TGFs, were detected at the Auger Observatory. Their experimental signature and time evolution are very different from those of a shower produced by an ultrahigh-energy cosmic ray. They happen in coincidence with low thunderclouds and lightning, and their large deposited energy at the ground is compatible with that of a standard downward TGF with the source a few kilometers above the ground. A new trigger algorithm to increase the TGF-like event statistics was installed in the whole array. The study of the performance of the new trigger system during the lightning season is ongoing and will provide a handle to develop improved algorithms to implement in the Auger upgraded electronic boards. The available data sample, even if small, can give important clues about the TGF production models, in particular, the shape of WCD signals. Moreover, the SD allows us to observe more than one point in the TGF beam, providing information on the emission angle

    The dynamic range of the upgraded surface-detector stations of AugerPrime

    Get PDF
    The detection of ultra-high-energy cosmic rays by means of giant detector arrays is often limited by the saturation of the recorded signals near the impact point of the shower core at the ground, where the particle density dramatically increases. The saturation affects in particular the highest energy events, worsening the systematic uncertainties in the reconstruction of the shower characteristics. The upgrade of the Pierre Auger Observatory, called AugerPrime, includes the installation of an 1-inch Small PhotoMultiplier Tube (SPMT) inside each water-Cherenkov station (WCD) of the surface detector array. The SPMT allows an unambiguous measurement of signals down to about 250m from the shower core, thus reducing the number of events featuring a saturated station to a negligible level. In addition, a 3.8m2 plastic scintillator (Scintillator Surface Detector, SSD) is installed on top of each WCD. The SSD is designed to match the WCD (with SPMT) dynamic range, providing a complementary measurement of the shower components up to the highest energies. In this work, the design and performances of the upgraded AugerPrime surface-detector stations in the extended dynamic range are described, highlighting the accuracy of the measurements. A first analysis employing the unsaturated signals in the event reconstruction is also presented

    Measurements of Cloud Base Height and Coverage using Elastic Multiangle Lidar Scans at the Pierre Auger Observatory

    Get PDF
    corecore