1,309 research outputs found

    Optimum constrained image restoration filters

    Get PDF
    The filter was developed in Hilbert space by minimizing the radius of gyration of the overall or composite system point-spread function subject to constraints on the radius of gyration of the restoration filter point-spread function, the total noise power in the restored image, and the shape of the composite system frequency spectrum. An iterative technique is introduced which alters the shape of the optimum composite system point-spread function, producing a suboptimal restoration filter which suppresses undesirable secondary oscillations. Finally this technique is applied to multispectral scanner data obtained from the Earth Resources Technology Satellite to provide resolution enhancement. An experimental approach to the problems involving estimation of the effective scanner aperture and matching the ERTS data to available restoration functions is presented

    Constrained optimization of image restoration filters

    Get PDF
    A linear shift-invariant preprocessing technique is described which requires no specific knowledge of the image parameters and which is sufficiently general to allow the effective radius of the composite imaging system to be minimized while constraining other system parameters to remain within specified limits

    Conceptual Design of an In-Space Cryogenic Fluid Management Facility

    Get PDF
    The conceptual design of a Spacelab experiment to develop the technology associated with low gravity propellant management is presented. The proposed facility consisting of a supply tank, receiver tank, pressurization system, instrumentation, and supporting hardware, is described. The experimental objectives, the receiver tank to be modeled, and constraints imposed on the design by the space shuttle, Spacelab, and scaling requirements, are described. The conceptual design, including the general configurations, flow schematics, insulation systems, instrumentation requirements, and internal tank configurations for the supply tank and the receiver tank, is described. Thermal, structural, fluid, and safety and reliability aspects of the facility are analyzed. The facility development plan, including schedule and cost estimates for the facility, is presented. A program work breakdown structure and master program schedule for a seven year program are included

    Conceptual design of an in-space cryogenic fluid management facility, executive summary

    Get PDF
    The conceptual design of a Spacelab experiment to develop the technology associated with low gravity propellant management is summarized. The preliminary facility definition, conceptual design and design analysis, and facility development plan, including schedule and cost estimates for the facility, are presented

    Emissions of Volatile Organic Compounds Inferred From Airborne Flux Measurements over a Megacity

    Get PDF
    Toluene and benzene are used for assessing the ability to measure disjunct eddy covariance (DEC) fluxes of Volatile Organic Compounds (VOC) using Proton Transfer Reaction Mass Spectrometry (PTR-MS) on aircraft. Statistically significant correlation between vertical wind speed and mixing ratios suggests that airborne VOC eddy covariance (EC) flux measurements using PTR-MS are feasible. City-median midday toluene and benzene fluxes are calculated to be on the order of 14.1±4.0 mg/m<sup>2</sup>/h and 4.7±2.3 mg/m<sup>2</sup>/h, respectively. For comparison the adjusted CAM2004 emission inventory estimates toluene fluxes of 10 mg/m<sup>2</sup>/h along the footprint of the flight-track. Wavelet analysis of instantaneous toluene and benzene measurements during city overpasses is tested as a tool to assess surface emission heterogeneity. High toluene to benzene flux ratios above an industrial district (e.g. 10–15 g/g) including the International airport (e.g. 3–5 g/g) and a mean flux (concentration) ratio of 3.2±0.5 g/g (3.9±0.3 g/g) across Mexico City indicate that evaporative fuel and industrial emissions play an important role for the prevalence of aromatic compounds. Based on a tracer model, which was constrained by BTEX (BTEX– Benzene/Toluene/Ethylbenzene/m, p, o-Xylenes) compound concentration ratios, the fuel marker methyl-tertiary-butyl-ether (MTBE) and the biomass burning marker acetonitrile (CH<sub>3</sub>CN), we show that a combination of industrial, evaporative fuel, and exhaust emissions account for >87% of all BTEX sources. Our observations suggest that biomass burning emissions play a minor role for the abundance of BTEX compounds in the MCMA (2–13%)

    PET/CT Imaging for Personalized Management of Infectious Diseases

    Get PDF
    Positron emission tomography combined with computed tomography (PET/CT) is a nuclear imaging technique which is increasingly being used in infectious diseases. Because infection foci often consume more glucose than surrounding tissue, most infections can be diagnosed with PET/CT using 2-deoxy-2-[18F]fluoro-D-glucose (FDG), an analogue of glucose labeled with Fluorine-18. In this review, we discuss common infectious diseases in which FDG-PET/CT is currently applied including bloodstream infection of unknown origin, infective endocarditis, vascular graft infection, spondylodiscitis, and cyst infections. Next, we highlight the latest developments within the field of PET/CT, including total body PET/CT, use of novel PET radiotracers, and potential future applications of PET/CT that will likely lead to increased capabilities for patient-tailored treatment of infectious diseases

    Timing deficiencies in amnestic Mild Cognitive Impairment:Disentangling clock and memory processes

    Get PDF
    Interval timing performance in cognitive decline is typically characterized by decreased accuracy, precision, or both. One explanation for this decreased performance is a larger clock time variability. However, memory deficiencies associated with cognitive decline might also affect temporal performance in two alternative ways: First, memory deficiencies could lead to reduced encoding of just perceived durations, and thus a stronger reliance on the memory traces of previous experiences (the “prior”), yielding less precise reproductions of the most current experiences. Second, memory deficiencies could hamper the storage of perceived intervals, thus resulting in less influence of the prior. Here, we present data of 15 patients with amnestic Mild Cognitive Impairment (aMCI) and 44 healthy, aged controls, the latter split in two groups based on memory performance. All participants were tested on a temporal production task to assess clock time variability and a multi-duration reproduction task to assess the influence of memory traces reflecting current and previous experiences. Patients with aMCI showed the strongest regression towards the mean in a multi-duration reproduction task, followed by low-performing healthy controls and high-performing healthy controls, respectively. As no difference was observed between the groups in terms of clock time variability, and clock variability did not statistically contribute to the observed regression, this increased central tendency effect was not attributable to clock noise. We therefore, in line with the first explanation, conclude that memory deficiencies result in a stronger (relative) reliance on the prior
    • …
    corecore