791 research outputs found
Silicon photomultiplier arrays - a novel photon detector for a high resolution tracker produced at FBK-irst, Italy
A silicon photomultiplier (SiPM) array has been developed at FBK-irst having
32 channels and a dimension of 8.0 x 1.1 mm^2. Each 250 um wide channel is
subdivided into 5 x 22 rectangularly arranged pixels. These sensors are
developed to read out a modular high resolution scintillating fiber tracker.
Key properties like breakdown voltage, gain and photon detection efficiency
(PDE) are found to be homogeneous over all 32 channels of an SiPM array. This
could make scintillating fiber trackers with SiPM array readout a promising
alternative to available tracker technologies, if noise properties and the PDE
are improved
Influence of the Leakage Current on the Performance of Large Area Silicon Drift Detectors
In this paper we investigate the influence of the leakage current on the performance of Silicon Drift Detectors. First, analytical considerations are given in order to highlight the problems, specific for this type of detector, that emerge with leakage current. Then the obtained results are compared with the data of laboratory measurements. Aiming at a mass production of SDDs for the Inner Tracking System of the ALICE experiment at LHC we propose a simple and fast measurement for a preliminary selection before passing to a detailed acceptance test
A Scintillating Fiber Tracker With SiPM Readout
We present a prototype for the first tracking detector consisting of 250
micron thin scintillating fibers and silicon photomultiplier (SiPM) arrays. The
detector has a modular design, each module consists of a mechanical support
structure of 10mm Rohacell foam between two 100 micron thin carbon fiber skins.
Five layers of scintillating fibers are glued to both top and bottom of the
support structure. SiPM arrays with a channel pitch of 250 micron are placed in
front of the fibers. We show the results of the first module prototype using
multiclad fibers of types Bicron BCF-20 and Kuraray SCSF-81M that were read out
by novel 32-channel SiPM arrays from FBK-irst/INFN Perugia as well as
32-channel SiPM arrays produced by Hamamatsu. A spatial resolution of 88 micron
+/- 6 micron at an average yield of 10 detected photons per minimal ionizig
particle has been achieved.Comment: 5 pages, 7 figures, submitted as proceedings to the 11th Topical
Seminar on Innovative Particle and Radiation Detectors (IPRD08
SiPM and front-end electronics development for Cherenkov light detection
The Italian Institute of Nuclear Physics (INFN) is involved in the
development of a demonstrator for a SiPM-based camera for the Cherenkov
Telescope Array (CTA) experiment, with a pixel size of 66 mm. The
camera houses about two thousands electronics channels and is both light and
compact. In this framework, a R&D program for the development of SiPMs suitable
for Cherenkov light detection (so called NUV SiPMs) is ongoing. Different
photosensors have been produced at Fondazione Bruno Kessler (FBK), with
different micro-cell dimensions and fill factors, in different geometrical
arrangements. At the same time, INFN is developing front-end electronics based
on the waveform sampling technique optimized for the new NUV SiPM. Measurements
on 11 mm, 33 mm, and 66 mm NUV SiPMs
coupled to the front-end electronics are presentedComment: In Proceedings of the 34th International Cosmic Ray Conference
(ICRC2015), The Hague, The Netherlands. All CTA contributions at
arXiv:1508.0589
Measurements and tests on FBK silicon sensors with an optimized electronic design for a CTA camera
In October 2013, the Italian Ministry approved the funding of a Research &
Development (R&D) study, within the "Progetto Premiale TElescopi CHErenkov made
in Italy (TECHE)", devoted to the development of a demonstrator for a camera
for the Cherenkov Telescope Array (CTA) consortium. The demonstrator consists
of a sensor plane based on the Silicon Photomultiplier (SiPM) technology and on
an electronics designed for signal sampling. Preliminary tests on a matrix of
sensors produced by the Fondazione Bruno Kessler (FBK-Trento, Italy) and on
electronic prototypes produced by SITAEL S.p.A. will be presented. In
particular, we used different designs of the electronics in order to optimize
the output signals in terms of tail cancellation. This is crucial for
applications where a high background is expected, as for the CTA experiment.Comment: 5 pages, 6 figures; Proceedings of the 10th Workshop on Science with
the New Generation of High-Energy Gamma-ray experiments (SciNeGHE) -
PoS(Scineghe2014)00
Radiation Damage Studies of Silicon Photomultipliers
We report on the measurement of the radiation hardness of silicon
photomultipliers (SiPMs) manufactured by
Fondazione Bruno Kessler in Italy (1 mm and 6.2 mm), Center of
Perspective Technology and Apparatus in Russia (1 mm and 4.4 mm), and
Hamamatsu Corporation in Japan (1 mm). The SiPMs were irradiated using a
beam of 212 MeV protons at Massachusetts General Hospital, receiving fluences
of up to protons per cm with the SiPMs at operating
voltage. Leakage currents were read continuously during the irradiation. The
delivery of the protons was paused periodically to record scope traces in
response to calibrated light pulses to monitor the gains, photon detection
efficiencies, and dark counts of the SiPMs. The leakage current and dark noise
are found to increase with fluence. Te leakage current is found to be
proportional to the mean square deviation of the noise distribution, indicating
the dark counts are due to increased random individual pixel activation, while
SiPMs remain fully functional as photon detectors. The SiPMs are found to
anneal at room temperature with a reduction in the leakage current by a factor
of 2 in about 100 days.Comment: 35 pages, 25 figure
Beam test results of the irradiated Silicon Drift Detector for ALICE
The Silicon Drift Detectors will equip two of the six cylindrical layers of
high precision position sensitive detectors in the ITS of the ALICE experiment
at LHC. In this paper we report the beam test results of a SDD irradiated with
1 GeV electrons. The aim of this test was to verify the radiation tolerance of
the device under an electron fluence equivalent to twice particle fluence
expected during 10 years of ALICE operation.Comment: 6 pages,6 figures, to appear in the proceedings of International
Workshop In high Multiplicity Environments (TIME'05), 3-7 October 2005,
Zurich,Switzerlan
Development and tests of a new prototype detector for the XAFS beamline at Elettra Synchrotron in Trieste
The XAFS beamline at Elettra Synchrotron in Trieste combines X-ray absorption
spectroscopy and X-ray diffraction to provide chemically specific structural
information of materials. It operates in the energy range 2.4-27 keV by using a
silicon double reflection Bragg monochromator. The fluorescence measurement is
performed in place of the absorption spectroscopy when the sample transparency
is too low for transmission measurements or the element to study is too diluted
in the sample. We report on the development and on the preliminary tests of a
new prototype detector based on Silicon Drift Detectors technology and the
SIRIO ultra low noise front-end ASIC. The new system will be able to reduce
drastically the time needed to perform fluorescence measurements, while keeping
a short dead time and maintaining an adequate energy resolution to perform
spectroscopy. The custom-made silicon sensor and the electronics are designed
specifically for the beamline requirements.Comment: Proceeding of the 6YRM 12th-14th Oct 2015 - L'Aquila (Italy).
Accepted for publication on Journal of Physics: Conference Serie
A narrow band neutrino beam with high precision flux measurements
The ENUBET facility is a proposed narrow band neutrino beam where lepton
production is monitored at single particle level in the instrumented decay
tunnel. This facility addresses simultaneously the two most important
challenges for the next generation of cross section experiments: a superior
control of the flux and flavor composition at source and a high level of
tunability and precision in the selection of the energy of the outcoming
neutrinos. We report here the latest results in the development and test of the
instrumentation for the decay tunnel. Special emphasis is given to irradiation
tests of the photo-sensors performed at INFN-LNL and CERN in 2017 and to the
first application of polysiloxane-based scintillators in high energy physics.Comment: Poster presented at NuPhys2017 (London, 20-22 December 2017). 5
pages, 2 figure
Recommended from our members
Risk‐Treatment Paradox in the Selection of Transradial Access for Percutaneous Coronary Intervention
Background: Access site complications contribute to morbidity and mortality during percutaneous coronary intervention (PCI). Transradial arterial access significantly lowers the risk of access site complications compared to transfemoral arteriotomy. We sought to develop a prediction model for access site complications in patients undergoing PCI with femoral arteriotomy, and assess whether transradial access was selectively used in patients at high risk for complications. Methods and Results: We analyzed 17 509 patients who underwent PCI without circulatory support from 2008 to 2011 at 5 institutions. Transradial arterial access was used in 17.8% of patients. In those who underwent transfemoral access, 177 (1.2%) patients had access site complications. Using preprocedural clinical and demographic data, a prediction model for femoral arteriotomy complications was generated. The variables retained in the model included: elevated age (P<0.001), female gender (P<0.001), elevated troponin (P<0.001), decreased renal function or dialysis (P=0.002), emergent PCI (P=0.01), prior PCI (P=0.005), diabetes (P=0.008), and peripheral artery disease (P=0.003). The model showed moderate discrimination (optimism‐adjusted c‐statistic=0.72) and was internally validated via bootstrap resampling. Patients with higher predicted risk of complications via transfemoral access were less likely to receive transradial access (P<0.001). Similar results were seen in patients presenting with and without ST‐segment myocardial infarction and when adjusting for individual physician operator. Conclusions: We generated and validated a model for transfemoral access site complications during PCI. Paradoxically, patients most likely to develop access site complications from transfemoral access, and therefore benefit from transradial access, were the least likely to receive transradial access
- …