51 research outputs found

    Adherence with statins in a real-life setting is better when associated cardiovascular risk factors increase: a cohort study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>While the factors for poor adherence for treatment with statins have been highlighted, the impact of their combination on adherence is not clear.</p> <p>Aims</p> <p>To estimate adherence for statins and whether it differs according to the number of cardiovascular risk factors.</p> <p>Methods</p> <p>A cohort study was conducted using data from the main French national health insurance system reimbursement database. Newly treated patients with statins between September 1 and December 31, 2004 were included. Patients were followed up 15 months. The cohort was split into three groups according to their number of additional cardiovascular risk factors that included age and gender, diabetes mellitus and cardiovascular disease (using co-medications as a <it>proxy</it>). Adherence was assessed for each group by using four parameters: <it>(i) </it>proportion of days covered by statins, <it>(ii) </it>regularity of the treatment over time, <it>(iii) </it>persistence, and <it>(iv) </it>the refill delay.</p> <p>Results</p> <p>16,397 newly treated patients were identified. Of these statin users, 21.7% did not have additional cardiovascular risk factors. Thirty-one percent had two cardiovascular risk factors and 47% had at least three risk factors. All the parameters showed a sub-optimal adherence whatever the group: days covered ranged from 56% to 72%, regularity ranged from 23% to 33% and persistence ranged from 44% to 59%, but adherence was better for those with a higher number of cardiovascular risk factors.</p> <p>Conclusions</p> <p>The results confirm that long-term drug treatments are a difficult challenge, particularly in patients at lower risk and invite to the development of therapeutic education.</p

    EPIdemiology of Surgery-Associated Acute Kidney Injury (EPIS-AKI) : Study protocol for a multicentre, observational trial

    Get PDF
    More than 300 million surgical procedures are performed each year. Acute kidney injury (AKI) is a common complication after major surgery and is associated with adverse short-term and long-term outcomes. However, there is a large variation in the incidence of reported AKI rates. The establishment of an accurate epidemiology of surgery-associated AKI is important for healthcare policy, quality initiatives, clinical trials, as well as for improving guidelines. The objective of the Epidemiology of Surgery-associated Acute Kidney Injury (EPIS-AKI) trial is to prospectively evaluate the epidemiology of AKI after major surgery using the latest Kidney Disease: Improving Global Outcomes (KDIGO) consensus definition of AKI. EPIS-AKI is an international prospective, observational, multicentre cohort study including 10 000 patients undergoing major surgery who are subsequently admitted to the ICU or a similar high dependency unit. The primary endpoint is the incidence of AKI within 72 hours after surgery according to the KDIGO criteria. Secondary endpoints include use of renal replacement therapy (RRT), mortality during ICU and hospital stay, length of ICU and hospital stay and major adverse kidney events (combined endpoint consisting of persistent renal dysfunction, RRT and mortality) at day 90. Further, we will evaluate preoperative and intraoperative risk factors affecting the incidence of postoperative AKI. In an add-on analysis, we will assess urinary biomarkers for early detection of AKI. EPIS-AKI has been approved by the leading Ethics Committee of the Medical Council North Rhine-Westphalia, of the Westphalian Wilhelms-University MĂŒnster and the corresponding Ethics Committee at each participating site. Results will be disseminated widely and published in peer-reviewed journals, presented at conferences and used to design further AKI-related trials. Trial registration number NCT04165369

    RESTORATION TECHNIQUE FOR PLEIADES-HR PANCHROMATIC IMAGES

    No full text
    17th of December 2011 from Kourou Space Centre, French Guyana. Like others high resolution optical satellites, it acquires both panchromatic images, with 70cm spatial resolution, and lower resolution multispectral images with 2.8m spatial resolution. Pleiades-HR is an optimized system, which means that the Modulation Transfer Function has a low value at Nyquist frequency, in order to reduce both the telescope diameter and aliasing effects. Shannon sampling condition is thus met at first order, which also makes classical ground processing, such as image matching or resampling, more justified for a mathematical point of view. Raw images are thus blurry which implies a deconvolution stage that restores sharpness but also increases the noise level in the high frequency domain. A denoising step, based upon wavelet packet coefficients thresholding/shrinkage technique, allows controlling the final noise level. Each of these methods includes numerous parameters that have to be assessed during the inflight commissioning period: deconvolution filter that depends on MTF assessment, instrumental noise model, noise level target for denoised images, wavelet packet decomposition level. This paper aims to precisely describe the deconvolution/denoising algorithms and how their main parameters have been set up during the inflight commissioning stage. Special attention will be given to structured noise induced by Pleiades-HR on board wavelet-based compression algorith

    An athermal measurement technique for long traps characterization in GaN HEMT transistors.

    No full text
    International audienceGaN High Electron Mobility Transistors (HEMTs) is very promising for high power switching and radiofrequency operation. However, the lack of reliability feedback is one of its major drawbacks. Trapping effect especially is one of the main performance limitations of such components. Many measurement techniques exist for trapping effects characterization, especially for short traps (”s to several ms). However for longer time constants, self-heating may distort the measurements. This paper presents an electrical and athermal transient measurement method which has been developed to study the trapping and detrapping time constants of such components. It allows the extraction of long transients without self-heating problems and is usable in long term electrical stress experiments. A simulation of this method with a simplified component's model and the measurements results are presented. With this technique, we investigated especially the long time constants (τ>20 ms) over a range of temperature from 10°C to 90°C. We observed three thermally activated trap signatures on GaN devices with our method

    PLEIADES-HR INNOVATIVE TECHNIQUES FOR RADIOMETRIC IMAGE QUALITY COMMISSIONING

    No full text
    The first Pleiades-HR satellite, part of a constellation of two, has been launched on December 17, 2011. This satellite produces high resolution optical images. In order to achieve good image quality, Pleiades-HR should first undergo an important 6 month commissioning phase period. This phase consists in calibrating and assessing the radiometric and geometric image quality to offer the best images to end users. This new satellite has benefited from technology improvements in various fields which make it stand out from other Earth observation satellites. In particular, its best-in-class agility performance enables new calibration and assessment techniques. This paper is dedicated to presenting these innovative techniques that have been tested for the first time for the Pleiades- HR radiometric commissioning. Radiometric activities concern compression, absolute calibration, detector normalization, and refocusing operations, MTF (Modulation Transfer Function) assessment, signal-to-noise ratio (SNR) estimation, and tuning of the ground processing parameters. The radiometric performances of each activity are summarized in this paper
    • 

    corecore