2,953 research outputs found

    Low temperature scale for a 1 to 20 degree Kelvin region

    Get PDF
    New temperature scale, accurate to better than plus or minus 0.001 Kelvin over low temperature region, is based on National Bureau of Standards 1955 platinum resistance thermometer scale and utilizes precise susceptibility measurements on two paramagnetic salts

    GRB Flares: UV/Optical Flaring (Paper I)

    Full text link
    We present a new algorithm for the detection of flares in gamma-ray burst (GRB) light curves and use this algorithm to detect flares in the UV/optical. The algorithm makes use of the Bayesian Information Criterion (BIC) to analyze the residuals of the fitted light curve, removing all major features, and to determine the statistically best fit to the data by iteratively adding additional `breaks' to the light curve. These additional breaks represent the individual components of the detected flares: T_start, T_stop, and T_peak. We present the detection of 119 unique flaring periods detected by applying this algorithm to light curves taken from the Second Swift Ultraviolet/Optical Telescope (UVOT) GRB Afterglow Catalog. We analyzed 201 UVOT GRB light curves and found episodes of flaring in 68 of the light curves. For those light curves with flares, we find an average number of ~2 flares per GRB. Flaring is generally restricted to the first 1000 seconds of the afterglow, but can be observed and detected beyond 10^5 seconds. More than 80% of the flares detected are short in duration with Delta t/t of < 0.5. Flares were observed with flux ratios relative to the underlying light curve of between 0.04 to 55.42. Many of the strongest flares were also seen at greater than 1000 seconds after the burst.Comment: Submitted to ApJ. 20 pages (including 8 figures and 1 table

    Lattice distortion in hcp rare gas solids

    Get PDF
    The lattice distortion parameter δc/a8/3\delta \equiv c/a-\sqrt{8/3} has been calculated as a function of molar volume for the hcp phases of He, Ar, Kr and Xe. Results from both semi-empirical potentials and density functional theory are presented. Our study shows that δ\delta is negative for helium in the entire pressure range. For Ar, Kr and Xe, however, δ\delta changes sign from negative to positive as the pressure increases, growing rapidly in magnitude at higher pressures.Comment: Submitted to Low. Temp. Phys., 14 pages, 5 figure

    Effects of deformation on superconducting metals

    Get PDF
    An A.C. mutual inductance method was used to measure the effects of deformation on the superconducting critical field curve for tin. The deformation was produced by pushing on the ends of a cylindrical sample which had a length to diameter ratio of unity. It was found that a 2% deformation produced no change in the shape of the critical field curve but only shifted it upward about 1.5 oersteds

    In-situ measurement of the permittivity of helium using microwave NbN resonators

    Full text link
    By measuring the electrical transport properties of superconducting NbN quarter-wave resonators in direct contact with a helium bath, we have demonstrated a high-speed and spatially sensitive sensor for the permittivity of helium. In our implementation a 103\sim10^{-3} mm3^3 sensing volume is measured with a bandwidth of 300 kHz in the temperature range 1.8 to 8.8 K. The minimum detectable change of the permittivity of helium is calculated to be 6×\sim6\times101110^{-11} ϵ0\epsilon_0/Hz1/2^{1/2} with a sensitivity of order 101310^{-13} ϵ0\epsilon_0/Hz1/2^{1/2} easily achievable. Potential applications include operation as a fast, localized helium thermometer and as a transducer in superfluid hydrodynamic experiments.Comment: 4 pages, 3 figure

    Pleistocene Histroy of Mississippi River (Abstract)

    Get PDF
    From its earliest known record immediately prior to the advance of the Nebraskan glacier to the present time the course of Mississippi River was affected by each advancing ice sheet in turn. The Nebraskan glacier displaced it to the east, the Kansan glacier shoved it farther east, the Illinoian glacier pushed it back west, with the retreat of the Illinoian ice it took an easterly course again, the Iowan or earliest Wisconsin glacier diverted it from one minor channel to another, the Green River lobe of the Tazewell Wisconsin ice sheet forced it back into a western course and started the Rock Island rapids, and the latest Wisconsin or Mankato invasion resulted in a great fill and the details of the course as it now is

    Rare manifestation of a c.290 C\u3eT, p.Gly97Glu VCP mutation

    Get PDF
    Introduction. The valosin-containing protein (VCP) regulates several distinct cellular processes. Consistent with this, VCP mutations manifest variable clinical phenotypes among and within families and are a diagnostic challenge. Methods. A 60-year-old man who played ice hockey into his 50’s was evaluated by electrodiagnostics, muscle biopsy, and molecular genetics. Results. With long-standing pes cavus and toe walking, our patient developed progressive weakness, cramps, memory loss, and paresthesias at age 52. An axonal sensorimotor neuropathy was found upon repeated testing at age 58. Neuropathic histopathology was present in the quadriceps, and exome sequencing revealed the VCP mutation c.290 C>T, p.Gly97Glu. Conclusions. Our patient reflects the clinical heterogeneity of VCP mutations, as his neurological localization is a spectrum between a lower motor neuron disorder and a hereditary axonal peripheral neuropathy such as CMT2. Our case demonstrates a rare manifestation of the c.290 C>T, pGly97Glu VCP mutation

    A versatile and compact capacitive dilatometer

    Full text link
    We describe the design, construction, calibration, and operation of a relatively simple differential capacitive dilatometer suitable for measurements of thermal expansion and magnetostriction from 300 K to below 1 K with a low-temperature resolution of about 0.05 angstroms. The design is characterized by an open architecture permitting measurements on small samples with a variety of shapes. Dilatometers of this design have operated successfully with a commercial physical property measurement system, with several types of cryogenic refrigeration systems, in vacuum, in helium exchange gas, and while immersed in liquid helium (magnetostriction only) to temperatures of 30 mK and in magnetic fields to 45 T.Comment: 8 pages, incorporating 6 figures, submitted to Rev. Sci. Instru
    corecore