513 research outputs found
Status of the Micromegas semi-DHCAL
The activities towards the fabrication and test of a 1 m3 semi-digital
hadronic calorime- ter are reviewed. The prototype sampling planes would
consist of 1 m2 Micromegas chambers with 1 cm2 granularity and embedded 2 bits
readout suitable for PFA calorime- try at an ILC detector. The design of the 1
m2 chamber is presented first, followed by an overview of the basic performance
of small prototypes. The basic units composing the 1 m2 chamber are 32 \times
48 cm2 boards with integrated electronics and a micro-mesh. Results of
character- ization tests of such boards are shown. Micromegas as a proportional
detector is well suited for semi-digital hadronic calorimetry. In order to
quantify the gain in perfor- mance when using one or more thresholds,
simulation studies are being carried out, some of which will be reported in
this contribution
Growth on blood agar discriminates Mycobacterium avium and Mycobacterium intracellulare
Mycobacterium intracellulare and Mycobacterium avium (MAC) require specialized culture and identification procedures. To simplify the diagnosis, we inoculated reference strains, and 85 M. avium and 12 M. intracellulare clinical isolates, on egg-based and sheep blood agar. After 5 days of culture, there were significantly more colonies on sheep blood than on egg-based agar for M. avium (ratio: 250.5 ± 209) but not for M. intracellulare (ratio: 0.44 ±0.11). Using a ratio ≥20, the sensitivity of the identification of an MAC isolate as M. avium was 97.65%, the specificity was 100%, and the positive predictive value was 100%. Differential growth on egg-based and blood agar is an aid to the identification of MAC isolates
Test in a beam of large-area Micromegas chambers for sampling calorimetry
Application of Micromegas for sampling calorimetry puts specific constraints
on the design and performance of this gaseous detector. In particular, uniform
and linear response, low noise and stability against high ionisation density
deposits are prerequisites to achieving good energy resolution. A
Micromegas-based hadronic calorimeter was proposed for an application at a
future linear collider experiment and three technologically advanced prototypes
of 11 m were constructed. Their merits relative to the
above-mentioned criteria are discussed on the basis of measurements performed
at the CERN SPS test-beam facility
Evidence of a Louse-Borne Outbreak Involving Typhus in Douai, 1710-1712 during the War of Spanish Succession
Background: The new field of paleomicrobiology allows past outbreaks to be identified by testing dental pulp of human remains with PCR. Methods: We identified a mass grave in Douai, France dating from the early XVIII th century. This city was besieged during the European war of Spanish succession. We tested dental pulp from 1192 teeth (including 40 from Douai) by quantitative PCR (qPCR) for R. prowazekii and B. quintana. We also used ultra-sensitive suicide PCR to detect R. prowazekii and genotyped positive samples. Results and Discussion: In the Douai remains, we identified one case of B. quintana infection (by qPCR) and R. prowazekii (by suicide PCR) in 6/21 individuals (29%). The R. prowazekii was genotype B, a genotype previously found in a Spanish isolate obtained in the first part of the XX th century. Conclusion: Louse-borne outbreaks were raging during the XVIII th century; our results support the hypothesis that typhus was imported into Europe by Spanish soldiers from America
MICROMEGAS chambers for hadronic calorimetry at a future linear collider
Prototypes of MICROMEGAS chambers, using bulk technology and analog readout,
with 1x1cm2 readout segmentation have been built and tested. Measurements in
Ar/iC4H10 (95/5) and Ar/CO2 (80/20) are reported. The dependency of the
prototypes gas gain versus pressure, gas temperature and amplification gap
thickness variations has been measured with an 55Fe source and a method for
temperature and pressure correction of data is presented. A stack of four
chambers has been tested in 200GeV/c and 7GeV/c muon and pion beams
respectively. Measurements of response uniformity, detection efficiency and hit
multiplicity are reported. A bulk MICROMEGAS prototype with embedded digital
readout electronics has been assembled and tested. The chamber layout and first
results are presented
Sources of Klebsiella and Raoultella species on dairy farms: Be careful where you walk
Klebsiella spp. are a common cause of mastitis, milk loss, and culling on dairy farms. Control of Klebsiella mastitis is largely based on prevention of exposure of the udder to the pathogen. To identify critical control points for mastitis prevention, potential Klebsiella sources and transmission cycles in the farm environment were investigated, including oro-fecal transmission, transmission via the indoor environment, and transmission via the outdoor environment. A total of 305 samples was collected from 3 dairy farms in upstate New York in the summer of 2007, and included soil, feed crops, feed, water, rumen content, feces, bedding, and manure from alleyways and holding pens. Klebsiella spp. were detected in 100% of rumen samples, 89% of water samples, and approximately 64% of soil, feces, bedding, alleyway, and holding pen samples. Detection of Klebsiella spp. in feed crops and feed was less common. Genotypic identification of species using rpoB sequence data showed that Klebsiella pneumoniae was the most common species in rumen content, feces, and alleyways, whereas Klebsiella oxytoca, Klebsiella variicola, and Raoultella planticola were the most frequent species among isolates from soil and feed crops. Random amplified polymorphic DNA-based strain typing showed heterogeneity of Klebsiella spp. in rumen content and feces, with a median of 4 strains per 5 isolates. Observational and bacteriological data support the existence of an oro-fecal transmission cycle, which is primarily maintained through direct contact with fecal contamination or through ingestion of contaminated drinking water. Fecal shedding of Klebsiella spp. contributes to pathogen loads in the environment, including bedding, alleyways, and holding pens. Hygiene of alleyways and holding pens is an important component of Klebsiella control on dairy farms
DIRAC v2: a DIgital Readout Asic for hadronic Calorimeter
International audienceThis mixed-signal circuit is a 64 channels readout R&D ASIC for Micro-Pattern Gaseous Detectors (Micromegas, Gas Electron Multiplier) or Resistive Plate Chambers. These detectors are foreseen as the active part of a digital hadronic calorimeter for a high energy physics experiment at the International Linear Collider. Physics requirements lead to a highly granular hadronic calorimeter with up to fifty millions channels with probably only hit information (digital calorimeter). Each channel of the chip is made of a 4 gains charge preamplifier, a DC-servo loop, 3 switched comparators and a digital memory, thus providing additional energy information for a hit. For detector characterization, a multiplexed analog readout has been implemented. Configuration and readout are fully digital, indeed six 8-bit DACs are embedded to set comparators thresholds. Power-down circuitry has been included, decreasing the power consumption to 10 μW per channel. To achieve a low cost electronics, a cheap full CMOS 0.35 μm foundry process has been chosen and the floorplan has been designed to reduce Printed Circuit Board costs. The SPS beam tests of the DIRAC first version embedded in a bulk Micromegas will be presented. The second version has just been received and preliminary results will be detailed. Large area detectors equipped with these chips are planned to be put in the PS beam this year
Resistive micromegas for sampling calorimetry
MicromegasInternational audienceMicromegas is an attractive option for a gaseous sampling calorimeter. It delivers proportional and fast signals, achieves high efficiency to minimum ionising particles with a compact design and shows well-uniform performance over meter-square areas. The current R&D focuses on large- size spark-protected Micromegas with integrated front-end electronics. It targets an application at future linear colliders (LC) and possible upgrades of LHC experiments for the running at high luminosity. In the later case, occasional sparking should be suppressed to avoid dead-time and technical solutions using resistive coatings are investigated. Small prototypes of resistive and non-resistive Micromegas were constructed and tested in a beam at DESY. Results are reported with emphasis on the impact of the resistive layer on the detector performance
The STAR Silicon Strip Detector (SSD)
The STAR Silicon Strip Detector (SSD) completes the three layers of the
Silicon Vertex Tracker (SVT) to make an inner tracking system located inside
the Time Projection Chamber (TPC). This additional fourth layer provides two
dimensional hit position and energy loss measurements for charged particles,
improving the extrapolation of TPC tracks through SVT hits. To match the high
multiplicity of central Au+Au collisions at RHIC the double sided silicon strip
technology was chosen which makes the SSD a half million channels detector.
Dedicated electronics have been designed for both readout and control. Also a
novel technique of bonding, the Tape Automated Bonding (TAB), was used to
fullfill the large number of bounds to be done. All aspects of the SSD are
shortly described here and test performances of produced detection modules as
well as simulated results on hit reconstruction are given.Comment: 11 pages, 8 figures, 1 tabl
- …