510 research outputs found

    2.5D Flow MRI: 2D phase-contrast of the tricuspid valvular flow with automated valve-tracking

    Get PDF
    Tricuspid regurgitant velocity is a crucial biomarker in identifying pressure overload in the right heart, associated with diastolic dysfunction and pulmonary hypertension. 2D phase-contrast cannot quantify this flow, and echocardiography is used clinically. We developed a phase-contrast method which utilizes deep-learning algorithms to track the valvular slice in a cardiac phasedependent manner, which we call 2.5D flow. We studied its performance in nine healthy subjects and patients with tricuspid regurgitation. RV stroke volumes correlated better to forward flow volumes by 2.5D flow vs. static 2D phase-contrast (ICC=0.88 vs. 0.62). 2.5D flow characterized regurgitation in a patient

    Predictors of response to anti-TNF therapy in ankylosing spondylitis: results from the British Society for Rheumatology Biologics Register

    Get PDF
    Objective. Few data exist on the use of anti-TNF drugs for AS during routine clinical use in the UK. This report describes an improvement in Bath Ankylosing Spondylitis Disease Activity Index (BASDAI) and Bath Ankylosing Spondylitis Functional Index (BASFI) after 6 months of therapy in 261 patients enrolled in a national prospective observational register

    Quantification and visualization of cardiovascular 4D velocity mapping accelerated with parallel imaging or k-t BLAST: head to head comparison and validation at 1.5 T and 3 T

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Three-dimensional time-resolved (4D) phase-contrast (PC) CMR can visualize and quantify cardiovascular flow but is hampered by long acquisition times. Acceleration with SENSE or k-t BLAST are two possibilities but results on validation are lacking, especially at 3 T. The aim of this study was therefore to validate quantitative in vivo cardiac 4D-acquisitions accelerated with parallel imaging and k-t BLAST at 1.5 T and 3 T with 2D-flow as the reference and to investigate if field strengths and type of acceleration have major effects on intracardiac flow visualization.</p> <p>Methods</p> <p>The local ethical committee approved the study. 13 healthy volunteers were scanned at both 1.5 T and 3 T in random order with 2D-flow of the aorta and main pulmonary artery and two 4D-flow sequences of the heart accelerated with SENSE and k-t BLAST respectively. 2D-image planes were reconstructed at the aortic and pulmonary outflow. Flow curves were calculated and peak flows and stroke volumes (SV) compared to the results from 2D-flow acquisitions. Intra-cardiac flow was visualized using particle tracing and image quality based on the flow patterns of the particles was graded using a four-point scale.</p> <p>Results</p> <p>Good accuracy of SV quantification was found using 3 T 4D-SENSE (r<sup>2 </sup>= 0.86, -0.7 ± 7.6%) and although a larger bias was found on 1.5 T (r<sup>2 </sup>= 0.71, -3.6 ± 14.8%), the difference was not significant (p = 0.46). Accuracy of 4D k-t BLAST for SV was lower (p < 0.01) on 1.5 T (r<sup>2 </sup>= 0.65, -15.6 ± 13.7%) compared to 3 T (r<sup>2 </sup>= 0.64, -4.6 ± 10.0%). Peak flow was lower with 4D-SENSE at both 3 T and 1.5 T compared to 2D-flow (p < 0.01) and even lower with 4D k-t BLAST at both scanners (p < 0.01). Intracardiac flow visualization did not differ between 1.5 T and 3 T (p = 0.09) or between 4D-SENSE or 4D k-t BLAST (p = 0.85).</p> <p>Conclusions</p> <p>The present study showed that quantitative 4D flow accelerated with SENSE has good accuracy at 3 T and compares favourably to 1.5 T. 4D flow accelerated with k-t BLAST underestimate flow velocities and thereby yield too high bias for intra-cardiac quantitative in vivo use at the present time. For intra-cardiac 4D-flow visualization, however, 1.5 T and 3 T as well as SENSE or k-t BLAST can be used with similar quality.</p

    Plasma interferon-alpha is associated with double-positivity for autoantibodies but is not a predictor of remission in early rheumatoid arthritis-a spin-off study of the NORD-STAR randomized clinical trial

    Get PDF
    BACKGROUND: The type I interferon (IFN) gene signature is present in a subgroup of patients with early rheumatoid arthritis (RA). Protein levels of IFNα have not been measured in RA and it is unknown whether they associate with clinical characteristics or treatment effect. METHODS: Patients with early untreated RA (n = 347) were randomized to methotrexate combined with prednisone, certolizumab-pegol, abatacept, or tocilizumab. Plasma IFNα protein levels were determined by single molecular array (Simoa) before and 24 weeks after treatment initiation and were related to demographic and clinical factors including clinical disease activity index, disease activity score in 28 joints, swollen and tender joint counts, and patient global assessment. RESULTS: IFNα protein positivity was found in 26% of the patients, and of these, 92% were double-positive for rheumatoid factor (RF) and anti-citrullinated protein antibodies (ACPA). IFNα protein levels were reduced 24 weeks after treatment initiation, and the absolute change was similar irrespective of treatment. IFNα protein positivity was associated neither with disease activity nor with achievement of CDAI remission 24 weeks after randomization. CONCLUSION: IFNα protein positivity is present in a subgroup of patients with early RA and associates with double-positivity for autoantibodies but not with disease activity. Pre-treatment IFNα positivity did not predict remission in any of the treatment arms, suggesting that the IFNα system is distinct from the pathways of TNF, IL-6, and T-cell activation in early RA. A spin-off study of the NORD-STAR randomized clinical trial, NCT01491815 (ClinicalTrials), registered 12/08/2011, https://clinicaltrials.gov/ct2/show/NCT01491815

    Development and validation of a patient-reported outcome measure for systemic sclerosis: the EULAR Systemic Sclerosis Impact of Disease (ScleroID) questionnaire

    Get PDF
    OBJECTIVES: Patient-reported outcome measures (PROMs) are important for clinical practice and research. Given the high unmet need, our aim was to develop a comprehensive PROM for systemic sclerosis (SSc), jointly with patient experts. METHODS: This European Alliance of Associations for Rheumatology (EULAR)-endorsed project involved 11 European SSc centres. Relevant health dimensions were chosen and prioritised by patients. The resulting Systemic Sclerosis Impact of Disease (ScleroID) questionnaire was subsequently weighted and validated by Outcome Measures in Rheumatology criteria in an observational cohort study, cross-sectionally and longitudinally. As comparators, SSc-Health Assessment Questionnaire (HAQ), EuroQol Five Dimensional (EQ-5D), Short Form-36 (SF-36) were included. RESULTS: Initially, 17 health dimensions were selected and prioritised. The top 10 health dimensions were selected for the ScleroID questionnaire. Importantly, Raynaud's phenomenon, impaired hand function, pain and fatigue had the highest patient-reported disease impact. The validation cohort study included 472 patients with a baseline visit, from which 109 had a test-retest reliability visit and 113 had a follow-up visit (85% female, 38% diffuse SSc, mean age 58 years, mean disease duration 9 years). The total ScleroID score showed strong Pearson correlation coefficients with comparators (SSc-HAQ, 0.73; Patient's global assessment, Visual Analogue Scale 0.77; HAQ-Disability Index, 0.62; SF-36 physical score, -0.62; each p<0.001). The internal consistency was strong: Cronbach's alpha was 0.87, similar to SSc-HAQ (0.88) and higher than EQ-5D (0.77). The ScleroID had excellent reliability and good sensitivity to change, superior to all comparators (intraclass correlation coefficient 0.84; standardised response mean 0.57). CONCLUSIONS: We have developed and validated the EULAR ScleroID, which is a novel, brief, disease-specific, patient-derived, disease impact PROM, suitable for research and clinical use in SSc

    Disappearance of myocardial perfusion defects on prone SPECT imaging: Comparison with cardiac magnetic resonance imaging in patients without established coronary artery disease

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>It is of great clinical importance to exclude myocardial infarction in patients with suspected coronary artery disease who do not have stress-induced ischemia. The diagnostic use of myocardial perfusion single-photon emission computed tomography (SPECT) in this situation is sometimes complicated by attenuation artifacts that mimic myocardial infarction. Imaging in the prone position has been suggested as a method to overcome this problem.</p> <p>Methods</p> <p>In this study, 52 patients without known prior infarction and no stress-induced ischemia on SPECT imaging were examined in both supine and prone position. The results were compared with cardiac magnetic resonance imaging (CMR) with delayed-enhancement technique to confirm or exclude myocardial infarction.</p> <p>Results</p> <p>There were 63 defects in supine-position images, 37 of which disappeared in the prone position. None of the 37 defects were associated with myocardial infarction by CMR, indicating that all of them represented attenuation artifacts. Of the remaining 26 defects that did not disappear on prone imaging, myocardial infarction was confirmed by CMR in 2; the remaining 24 had no sign of ischemic infarction but 2 had other kinds of myocardial injuries. In 3 patients, SPECT failed to detect small scars identified by CMR.</p> <p>Conclusion</p> <p>Perfusion defects in the supine position that disappeared in the prone position were caused by attenuation, not myocardial infarction. Hence, imaging in the prone position can help to rule out ischemic heart disease for some patients admitted for SPECT with suspected but not documented ischemic heart disease. This would indicate a better prognosis and prevent unnecessary further investigations and treatment.</p
    corecore