457 research outputs found
CTF3: Design of Driving Beam Combiner Ring
In CTF3 the beam compression of the driving beam structure between the main linac and the decelerating section is obtained with a delay loop and a combiner ring which increase the pulse current by a factor 10. The design of the combiner ring is presented. Tunable isochronicity condition, corrected up to second order, should assure preservation of the correlation in the longitudinal phase space during the compression. Path-length tuning devices are included in the combiner ring layout to compensate for orbit variations
Electromagnetic characterization of the 990 ton gapless magnets for the OPERA experiment
The instrumented targets of the OPERA neutrino experiment are complemented by two massive spectrometers based on gapless iron magnets. In 2006, a systematic assessment of their electromagnetic properties have been carried out. In this document, we report the results of such characterization and demonstrate that the achieved performance fulfill the physics requirements for the study of νμ→ντ oscillations
The PLASMONX Project for advanced beam physics experiments
The Project PLASMONX is well progressing into its
design phase and has entered as well its second phase of
procurements for main components. The project foresees
the installation at LNF of a Ti:Sa laser system (peak
power > 170 TW), synchronized to the high brightness
electron beam produced by the SPARC photo-injector.
The advancement of the procurement of such a laser
system is reported, as well as the construction plans of a
new building at LNF to host a dedicated laboratory for
high intensity photon beam experiments (High Intensity
Laser Laboratory). Several experiments are foreseen
using this complex facility, mainly in the high gradient
plasma acceleration field and in the field of mono-
chromatic ultra-fast X-ray pulse generation via Thomson
back-scattering. Detailed numerical simulations have
been carried out to study the generation of tightly focused
electron bunches to collide with laser pulses in the
Thomson source: results on the emitted spectra of X-rays
are presented
Improving low-dose blood-brain barrier permeability quantification using sparse high-dose induced prior for Patlak model
Blood-brain barrier permeability (BBBP) measurements extracted from the perfusion computed tomography (PCT) using the Patlak model can be a valuable indicator to predict hemorrhagic transformation in patients with acute stroke. Unfortunately, the standard Patlak model based PCT requires excessive radiation exposure, which raised attention on radiation safety. Minimizing radiation dose is of high value in clinical practice but can degrade the image quality due to the introduced severe noise. The purpose of this work is to construct high quality BBBP maps from low-dose PCT data by using the brain structural similarity between different individuals and the relations between the high- and low-dose maps. The proposed sparse high-dose induced (shd-Patlak) model performs by building a high-dose induced prior for the Patlak model with a set of location adaptive dictionaries, followed by an optimized estimation of BBBP map with the prior regularized Patlak model. Evaluation with the simulated low-dose clinical brain PCT datasets clearly demonstrate that the shd-Patlak model can achieve more significant gains than the standard Patlak model with improved visual quality, higher fidelity to the gold standard and more accurate details for clinical analysis. Copyright 2013 Elsevier B.V. All rights reserved
First events from the CNGS neutrino beam detected in the OPERA experiment
The OPERA neutrino detector at the underground Gran Sasso Laboratory (LNGS)
was designed to perform the first detection of neutrino oscillations in
appearance mode, through the study of nu_mu to nu_tau oscillations. The
apparatus consists of a lead/emulsion-film target complemented by electronic
detectors. It is placed in the high-energy, long-baseline CERN to LNGS beam
(CNGS) 730 km away from the neutrino source. In August 2006 a first run with
CNGS neutrinos was successfully conducted. A first sample of neutrino events
was collected, statistically consistent with the integrated beam intensity.
After a brief description of the beam and of the various sub-detectors, we
report on the achievement of this milestone, presenting the first data and some
analysis results.Comment: Submitted to the New Journal of Physic
Proposal for taking data with the KLOE-2 detector at the DANE collider upgraded in energy
This document reviews the physics program of the KLOE-2 detector at
DANE upgraded in energy and provides a simple solution to run the
collider above the -peak (up to 2, possibly 2.5 GeV). It is shown how a
precise measurement of the multihadronic cross section in the energy region up
to 2 (possibly 2.5) GeV would have a major impact on the tests of the Standard
Model through a precise determination of the anomalous magnetic moment of the
muon and the effective fine-structure constant at the scale. With a
luminosity of about cms, DANE upgraded in energy
can perform a scan in the region from 1 to 2.5 GeV in one year by collecting an
integrated luminosity of 20 pb (corresponding to a few days of data
taking) for single point, assuming an energy step of 25 MeV. A few years of
data taking in this region would provide important tests of QCD and effective
theories by physics with open thresholds for pseudo-scalar (like
the ), scalar (, etc...) and axial-vector (, etc...)
mesons; vector-mesons spectroscopy and baryon form factors; tests of CVC and
searches for exotics. In the final part of the document a technical solution
for the energy upgrade of DANE is proposed.Comment: 19 pages, 8 figure
The CERN Neutrino beam to Gran Sasso (NGS)
The conceptual technical design of the NGS (CERN neutrino beam to Gran Sasso) facility has been presented in the report CERN 98-02 / INFN-AE/98-05. Additional information, in particular an update on various neutrino beam options for the NGS facility, has been provided in a memorandum to the CERN-SPSC Committee (CERN-SPSC/98-35). In the present report, further improvements on the NGS design and performance, in particular new scenarios for SPS proton cycles for NGS operation and a new version of the NGS "high energy" neutrino beam for nt appearance experiments, are described. This new NGS reference beam is estimated to provide three times more nt events per year than the beam presented in the 1998 report. The radiological aspects of the NGS facility have been re-examined with the new beam design. An updated version of the construction schedule is also presented
Management of tiny unruptured intracranial aneurysms: A comparative effectiveness analysis
© 2017 American Medical Association. All rights reserved. Importance: Unruptured intracranial aneurysms (UIAs) are relatively common in the general population and are being increasingly diagnosed; a significant proportion are tiny (≤3 mm) aneurysms. There is significant heterogeneity in practice and lack of clear guidelines on the management of incidental, tiny UIAs. It is important to quantify the implications of different management strategies in terms of health benefits to patients. Objective: To evaluate the effectiveness of routine treatment (aneurysm coiling) vs 3 strategies for imaging surveillance compared with no preventive treatment or routine follow-up of tiny UIAs. Design, Setting, and Participants: A decision-analytic model-based comparative effectiveness analysis was conducted from May 1 to June 30, 2017, using inputs from the medical literature. PubMed searches were performed to identify relevant literature for all key model inputs, each of which was derived from the clinical study with the most robust data and greatest applicability. Analysis included 10 000 iterations simulating adult patients with incidental detections of UIAs 3 mm or smaller and no history of subarachnoid hemorrhage. Interventions: The following 5 management strategies for tiny UIAs were evaluated: annual magnetic resonance angiography (MRA) screening, biennial MRA screening, MRA screening every 5 years, aneurysm coiling and follow-up, and no treatment or preventive follow-up. Main Outcomes and Measures: A Markov decision model for lifetime rupture was constructed from a societal perspective per 10 000 patients with incidental, tiny UIAs. Outcomes were assessed in terms of quality-adjusted life-years. Probabilistic, 1-way, and 2-way sensitivity analyses were performed. Results: In this analysis of 10000 iterations simulating adult patients with a mean age of 50 years, the base-case calculation shows that the management strategy of no treatment or preventive follow-up has the highest health benefit (mean [SD] quality-adjusted life-years, 19.40[0.31]). Among the management strategies that incorporate follow-up imaging, MRA every 5 years is the best strategy with the next highest effectiveness (mean [SD] quality-adjusted life-years, 18.05 [0.62]). The conclusion remains robust in probabilistic and 1-way sensitivity analyses. Noroutine follow-up remains the optimal strategy when the annual growth rate and risk of rupture of growing aneurysms are varied. When the annual risk of rupture of nongrowing UIAs is less than 1.7%(0.23% in base case scenario), no follow-up is the optimal strategy. If annual risk of rupture is more than 1.7%, coiling should be performed directly. Conclusions and Relevance: Given the current literature, no preventive treatment or imaging follow-up is the most effective strategy in patients with aneurysms that are 3mm or smaller, resulting in better health outcomes. More aggressive imaging surveillance for aneurysm growth or preventive treatment should be reserved for patients with a high risk of rupture. Given these findings, it is important to critically evaluate the appropriateness of current clinical practices, and potentially determine specific guidelines to reflect the most effective management strategy for patients with incidental, tiny UIAs
- …
