738 research outputs found
Stem cells in drug discovery, regenerative medicine and cancer
A report on the Stem Cells World Congress held in San Diego, USA, 24-25 January 2011
Fractoluminescence characterization of the energy dissipated during fast fracture of glass
Fractoluminescence experiments are performed on two kinds of silicate
glasses. All the light spectra collected during dynamic fracture reveal a black
body radiator behaviour, which is interpreted as a crack velocity-dependent
temperature rise close to the crack tip. Crack velocities are estimated to be
of the order of 1300 m.s and fracture process zones are shown to extend
over a few nanometers.Comment: Accepted for publication in Europhysics Letters; 5 pages; 4 figure
Evidence of Deep Water Penetration in Silica during Stress Corrosion Fracture
We measure the thickness of the heavy water layer trapped under the stress corrosion fracture surface of silica using neutron reflectivity experiments. We show that the penetration depth is 65–85 Å, suggesting the presence of a damaged zone of ~100 Å extending ahead of the crack tip during its propagation. This estimate of the size of the damaged zone is compatible with other recent results
Isolation of CD133+ Liver Stem Cells for Clonal Expansion
Liver stem cell, or oval cells, proliferate during chronic liver injury, and are proposed to differentiate into both hepatocytes and cholangiocytes. In addition, liver stem cells are hypothesized to be the precursors for a subset of liver cancer, Hepatocellular carcinoma. One of the primary challenges to stem cell work in any solid organ like the liver is the isolation of a rare population of cells for detailed analysis. For example, the vast majority of cells in the liver are hepatocytes (parenchymal fraction), which are significantly larger than non-parenchymal cells. By enriching the specific cellular compartments of the liver (i.e. parenchymal and non-parenchymal fractions), and selecting for CD45 negative cells, we are able to enrich the starting population of stem cells by over 600-fold.The proceduresdetailed in this report allow for a relatively rare population of cells from a solid organ to be sorted efficiently. This process can be utilized to isolateliver stem cells from normal murine liver as well as chronic liver injury models, which demonstrate increased liver stem cell proliferation. This method has clear advantages over standard immunohistochemistry of frozen or formalin fixed liver as functional studies using live cells can be performed after initial co-localization experiments. To accomplish the procedure outlined in this report, a working relationship with a research based flow-cytometry core is strongly encouraged as the details of FACS isolation are highly dependent on specialized instrumentation and a strong working knowledge of basic flow-cytometry procedures. The specific goal of this process is to isolate a population of liver stem cells that can be clonally expanded in vitro
Inelastic interaction mean free path of negative pions in tungsten
The inelastic interaction mean free paths lambda of 5, 10, and 15 GeV/c pions were measured by determining the distribution of first interaction locations in a modular tungsten-scintillator ionization spectrometer. In addition to commonly used interaction signatures of a few (2-5) particles in two or three consecutive modules, a chi2 distribution is used to calculate the probability that the first interaction occurred at a specific depth in the spectrometer. This latter technique seems to be more reliable than use of the simpler criteria. No significant dependence of lambda on energy was observed. In tungsten, lambda for pions is 206 plus or minus 6 g/sq cm
Towards an optimal design for ecosystem-level ocean observatories
Four operational factors, together with high development cost, currently limit the use of ocean observatories in ecological and fisheries applications: 1) limited spatial coverage; 2) limited integration of multiple types of technologies; 3) limitations in the experimental design for in situ studies; and 4) potential unpredicted bias in monitoring outcomes due to the infrastructure’s presence and functioning footprint. To address these limitations, we propose a novel concept of a standardized “ecosystem observatory module” structure composed of a central node and three tethered satellite pods together with permanent mobile platforms. The module would be designed with a rigid spatial configuration to optimize overlap among multiple observation technologies each providing 360° coverage around the module, including permanent stereo-video cameras, acoustic imaging sonar cameras, horizontal multi-beam echosounders and a passive acoustic array. The incorporation of multiple integrated observation technologies would enable unprecedented quantification of macrofaunal composition, abundance and density surrounding the module, as well as the ability to track the movements of individual fishes and macroinvertebrates. Such a standardized modular design would allow for the hierarchical spatial connection of observatory modules into local module clusters and larger geographic module networks, providing synoptic data within and across linked ecosystems suitable for fisheries and ecosystem level monitoring on multiple scales.Peer ReviewedPostprint (author's final draft
Chapter 2 Towards an Optimal Design for Ecosystem-Level Ocean Observatories
Four operational factors, together with high development cost, currently limit the use of ocean observatories in ecological and fisheries applications: 1) limited spatial coverage; 2) limited integration of multiple types of technologies; 3) limitations in the experimental design for in situ studies; and 4) potential unpredicted bias in monitoring outcomes due to the infrastructure’s presence and functioning footprint. To address these limitations, we propose a novel concept of a standardized “ecosystem observatory module” structure composed of a central node and three tethered satellite pods together with permanent mobile platforms. The module would be designed with a rigid spatial configuration to optimize overlap among multiple observation technologies each providing 360° coverage of a cylindrical or hemi-spherical volume around the module, including permanent stereo-video cameras, acoustic imaging sonar cameras, horizontal multi-beam echosounders and a passive acoustic array. The incorporation of multiple integrated observation technologies would enable unprecedented quantification of macrofaunal composition, abundance and density surrounding the module, as well as the ability to track the movements of individual fishes and macroinvertebrates. Such a standardized modular design would allow for the hierarchical spatial connection of observatory modules into local module clusters and larger geographic module networks, providing synoptic data within and across linked ecosystems suitable for fisheries and ecosystem level monitoring on multiple scales
- …