1,759 research outputs found

    Peatlands and the carbon cycle: from local processes to global implications - a synthesis

    Get PDF
    Peatlands cover only 3% of the Earth's land surface but boreal and subarctic peatlands store about 15-30% of the world's soil carbon ( C) as peat. Despite their potential for large positive feedbacks to the climate system through sequestration and emission of greenhouse gases, peatlands are not explicitly included in global climate models and therefore in predictions of future climate change. In April 2007 a symposium was held in Wageningen, the Netherlands, to advance our understanding of peatland C cycling. This paper synthesizes the main findings of the symposium, focusing on (i) small-scale processes, (ii) C fluxes at the landscape scale, and (iii) peatlands in the context of climate change. The main drivers controlling most are related to some aspects of hydrology. Despite high spatial and annual variability in Net Ecosystem Exchange ( NEE), the differences in cumulative annual NEE are more a function of broad scale geographic location and physical setting than internal factors, suggesting the existence of strong feedbacks. In contrast, trace gas emissions seem mainly controlled by local factors. Key uncertainties remain concerning the existence of perturbation thresholds, the relative strengths of the CO2 and CH4 feedback, the links among peatland surface climate, hydrology, ecosystem structure and function, and trace gas biogeochemistry as well as the similarity of process rates across peatland types and climatic zones. Progress on these research areas can only be realized by stronger co-operation between disciplines that address different spatial and temporal scales

    HybVent:Control Strategies for Hybrid Ventilation in New and Retrofitted Office Buildings

    Get PDF

    LESO Building - Report on monitoring

    Get PDF

    EPIQR-TOBUS: a new generation of refurbishment decision aid methods

    Get PDF
    In a large majority of European countries, the amount of maintenance and refurbishment works represents nearly 50% of the total amount spent in the building sector. New requirements are being added to the necessity of maintaining or re-establishing the building stock's usage value. They are linked to the determination to reduce energy consumption, pollutant emissions, work site wastes, to improve the Indoor Environment Quality (IEQ) and all the modern conveniences inside buildings. Two European projects, EPIQR (réf. nr.: JOR3-CT96-0044) and TOBUS (réf. nr.: JOR3-CT98-Û235), developed in the IIIrd and IVth framework programs put the foundations of a new generation of refurbishment decision aid tools. A structured diagnosis scheme covering the state of deterioration of the building elements, energy performance, indoor environment quality, functional obsolescence offer a new concept which helps architects and engineers to approach the building refurbishment with a global view of the whole process, to take informed decisions, to construct coherent refurbishment scenarii and calculate a reasonable investment budget in the very first stage of the refurbishment project. EPIQR project addresses residential buildings and it has been finished in 1998, TOBUS addresses office buildings and it is still in course. The support of these methods is a multimedia computer program. Several modules help the users to treat the data collected during a diagnosis survey, to set up refurbishment scenarii and calculate their cost or energy performance, and finally to visualise the results in a comprehensive way and to prepare quality reports. This paper presents the structure and the main features of the method and softwar

    A control and monitor system for the liquid argon cryogenics of the calorimeter of the ATLAS detector

    Get PDF
    In a few weeks the Large Hadron Collider which is built at CERN will deliver its first beam. ATLAS (A Toro dal Large hadron collider ApparatuS [1]) is one of the four experiments whose aim is to analyze the products of the collisions. As many of these particle detectors, ATLAS is designed with four concentric layers which are, from inside to outside: the inner detector to measure the charged particles tracks, the electromagnetic calorimeter to measure the energy deposited by both electrons and ph otons, then the hadronic calorimeter and finally the muon detector. The active part of the electromagnetic calorimeter is a bath of liquid argon [2] whose large volume (78 m(3)) has to be maintained precisely at its operating temperature (about 88 K) by t he means of nitrogen circulation. In this paper we will describe how with industry-like control systems an application has been built for the command and the monitoring of the whole cryogenics equipment

    DNA unzipped under a constant force exhibits multiple metastable intermediates

    Full text link
    Single molecule studies, at constant force, of the separation of double-stranded DNA into two separated single strands may provide information relevant to the dynamics of DNA replication. At constant applied force, theory predicts that the unzipped length as a function of time is characterized by jumps during which the strands separate rapidly, followed by long pauses where the number of separated base pairs remains constant. Here, we report previously uncharacterized observations of this striking behavior carried out on a number of identical single molecules simultaneously. When several single lphage molecules are subject to the same applied force, the pause positions are reproducible in each. This reproducibility shows that the positions and durations of the pauses in unzipping provide a sequence-dependent molecular fingerprint. For small forces, the DNA remains in a partially unzipped state for at least several hours. For larger forces, the separation is still characterized by jumps and pauses, but the double-stranded DNA will completely unzip in less than 30 min

    HIGH SPIN ISOMERIC STATES IN 197Pb

    No full text
    High spin isomeric states in 197Pb have been investigated by in-beam gamma ray technics. These states are produced in (heavy ion, xn) reactions. various experiments performed are summarized in table I

    Crossover from Luttinger- to Fermi-liquid behavior in strongly anisotropic systems in large dimensions

    Full text link
    We consider the low-energy region of an array of Luttinger liquids coupled by a weak interchain hopping. The leading logarithmic divergences can be re-summed to all orders within a self-consistent perturbative expansion in the hopping, in the large-dimension limit. The anomalous exponent scales to zero below the one-particle crossover temperature. As a consequence, coherent quasiparticles with finite weight appear along the whole Fermi surface. Extending the expansion self-consistently to all orders turns out to be crucial in order to restore the correct Fermi-liquid behavior.Comment: Shortened version to appear in Physical Review Letter
    • …
    corecore