112 research outputs found

    A new applicator design for endocavitary brachytherapy of cancer in the nasopharynx

    Get PDF
    Introduction: In attempting to improve local tumor control by higher doses of radiation, there has been a resurgence of interest in the implementation of brachytherapy in the management of primary and recurrent cancers of the nasopharynx. Brachytherapy with its steep dose fall-off is of particular interest because of the proximity of critical dose limiting structures. Recent developments in brachytherapy, such as the introduction of pulsed-dose-rate and high-dose-rate computerized afterloaders, have encouraged further evolution of brachytherapy techniques. Materials and methods: We have designed an inexpensive, re-usable and flexible silicone applicator, tailored to the shape of the soft tissues of the nasopharynx, which can be used with either low-dose-rate brachytherapy or high (pulsed)- dose-rate remote controlled afterloaders. Results and conclusions: This Rotterdam nasopharynx applicator proved to be easy to introduce, patient friendly and can remain in situ for the duration of the treatment (2-6 days). The design, technique of application and the first consecutive 5 years of clinical experience in using this applicator are presented

    A 3D-printed anatomical pancreas and kidney phantom for optimizing SPECT/CT reconstruction settings in beta cell imaging using 111In-exendin

    Get PDF
    Contains fulltext : 165641.pdf (publisher's version ) (Open Access)BACKGROUND: Quantitative single photon emission computed tomography (SPECT) is challenging, especially for pancreatic beta cell imaging with 111In-exendin due to high uptake in the kidneys versus much lower uptake in the nearby pancreas. Therefore, we designed a three-dimensionally (3D) printed phantom representing the pancreas and kidneys to mimic the human situation in beta cell imaging. The phantom was used to assess the effect of different reconstruction settings on the quantification of the pancreas uptake for two different, commercially available software packages. METHODS: 3D-printed, hollow pancreas and kidney compartments were inserted into the National Electrical Manufacturers Association (NEMA) NU2 image quality phantom casing. These organs and the background compartment were filled with activities simulating relatively high and low pancreatic 111In-exendin uptake for, respectively, healthy humans and type 1 diabetes patients. Images were reconstructed using Siemens Flash 3D and Hermes Hybrid Recon, with varying numbers of iterations and subsets and corrections. Images were visually assessed on homogeneity and artefacts, and quantitatively by the pancreas-to-kidney activity concentration ratio. RESULTS: Phantom images were similar to clinical images and showed comparable artefacts. All corrections were required to clearly visualize the pancreas. Increased numbers of subsets and iterations improved the quantitative performance but decreased homogeneity both in the pancreas and the background. Based on the phantom analyses, the Hybrid Recon reconstruction with 6 iterations and 16 subsets was found to be most suitable for clinical use. CONCLUSIONS: This work strongly contributed to quantification of pancreatic 111In-exendin uptake. It showed how clinical images of 111In-exendin can be interpreted and enabled selection of the most appropriate protocol for clinical use

    Adherence to a femoral neck fracture treatment guideline

    Get PDF
    Purpose: In 2007 the Dutch Surgical Society published a clinical practice guideline for the treatment of hip fracture patients, based on the best available international evidence at that time. We investigated to what extent treatment of femoral neck fracture patients in the Netherlands corresponded with these guidelines, and determined differences in patient characteristics between the treatment groups. Methods: All femoral neck fracture patients treated in 14 hospitals between February 2008 and August 2009 were included. Patient characteristics, X-rays, and treatment data were collected retrospectively. Results: From a total of 1,250 patients 59 % had been treated with arthroplasty, 39 % with internal fixation, and 2 % with a non-operative treatment. While 74 % of the treatment choices complied with the guideline, 12 % did not. In 14 % adherence could not be determined from the available data. Arthroplasty was preferred over internal fixation in elderly patients with severe comorbidity, pre-fracture osteoporosis and a displaced fracture, who were ambulatory with aids pre-fracture (odds ratio, OR 2.2-58.1). Sliding hip screws were preferred over cancellous screws in displaced fractures (OR 1.9). Conclusions: Overall guideline adherence was good. Most deviations concerned treatment of elderly patients with a displaced fracture and implant use in internal fixation. Additional data on these issues, preferably at a higher scientific level of evidence, is needed in order to improve the guideline and to reinforce a more uniform treatment of these patients

    Computer-aided detection in breast MRI: a systematic review and meta-analysis

    Get PDF
    To evaluate the additional value of computer-aided detection (CAD) in breast MRI by assessing radiologists' accuracy in discriminating benign from malignant breast lesions. A literature search was performed with inclusion of relevant studies using a commercially available CAD system with automatic colour mapping. Two independent researchers assessed the quality of the studies. The accuracy of the radiologists' performance with and without CAD was presented as pooled sensitivity and specificity. Of 587 articles, 10 met the inclusion criteria, all of good methodological quality. Experienced radiologists reached comparable pooled sensitivity and specificity before and after using CAD (sensitivity: without CAD: 89%; 95% CI: 78-94%, with CAD: 89%; 95%CI: 81-94%) (specificity: without CAD: 86%; 95% CI: 79-91%, with CAD: 82%; 95% CI: 76-87%). For residents the pooled sensitivity increased from 72% (95% CI: 62-81%) without CAD to 89% (95% CI: 80-94%) with CAD, however, not significantly. Concerning specificity, the results were similar (without CAD: 79%; 95% CI: 69-86%, with CAD: 78%; 95% CI: 69-84%). CAD in breast MRI has little influence on the sensitivity and specificity of experienced radiologists and therefore their interpretation remains essential. However, residents or inexperienced radiologists seem to benefit from CAD concerning breast MRI evaluation

    What's the effect of the implementation of general practitioner cooperatives on caseload? Prospective intervention study on primary and secondary care

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Out-of-hours care in the primary care setting is rapidly changing and evolving towards general practitioner 'cooperatives' (GPC). GPCs already exist in the Netherlands, the United Kingdom and Scandinavia, all countries with strong general practice, including gatekeepers' role. This intervention study reports the use and caseload of out-of-hours care before and after implementation of a GPC in a well subscribed region in a country with an open access health care system and no gatekeepers' role for general practice.</p> <p>Methods</p> <p>We used a prospective before/after interventional study design. The intervention was the implementation of a GPC.</p> <p>Results</p> <p>One year after the implementation of a GPC, the number of patient contacts in the intervention region significantly increased at the GPC (OR: 1.645; 95% CI: 1.439-1.880), while there were no significant changes in patient contacts at the Emergency Department (ED) or in other regions where a simultaneous registration was performed. Although home visits decreased in all general practitioner registrations, the difference was more pronounced in the intervention region (intervention region: OR: 0.515; 95% CI: 0.411-0.646, other regions: OR: 0.743; 95% CI: 0.608-0.908). At the ED we observed a decrease in the number of trauma cases (OR: 0.789; 95% CI: 0.648-0.960) and of patients who came to hospital by ambulance (OR: 0.687; 95% CI: 0.565-0.836).</p> <p>Conclusions</p> <p>One year after its implementation more people seek help at the GPC, while the number of contacts at the ED remains the same. The most prominent changes in caseload are found in the trauma cases. Establishing a GPC in an open health care system, might redirect some patients with particular medical problems to primary care. This could lead to a lowering of costs or a more cost-effective out of hours care, but further research should focus on effective usage to divert patient flows and on quality and outcome of care.</p

    Computer aided detection and guided breast biopsies using 3 tesla MRI

    No full text
    corecore