247 research outputs found

    Clinical Reliability of Complete-Arch Fixed Prostheses Supported by Narrow-Diameter Implants to Support Complete-Arch Restorations

    Get PDF
    The aim of this study was to evaluate the clinical application of fixed screw-retained complete-arch rehabilitations supported by four narrow-diameter implants (NDIs). The records of patients treated with complete-arch prostheses screwed onto four NDIs treated with an immediate loading protocol between 2010 and 2020 with at least 1 year of follow-up after the positioning of the definitive restoration were reviewed. The implants were placed according to the final prosthetic design and were immediately loaded. The interim prostheses were replaced after the healing period by definitive acrylic resin titanium-supported prostheses. Patients were followed to evaluate treatment success, the implant survival rate (ISR), and the prosthetic survival rate (PSR). A total of 121 NDIs were positioned in 30 patients to restore 30 complete arches (18 maxilla and 12 mandible). One implant did not achieve osseointegration, resulting in an overall ISR of 99.2%. No prosthetic or implant failures occurred during the 1 to 11 years of follow-up. Three biological and four prosthetic complications occurred, resulting in a treatment rehabilitation survival of 94.1% and a PSR of 86.7%. Despite the limitations of the present retrospective study, such as the use of one single type of dental implant and patients treated in a single rehabilitation center, complete-arch rehabilitation with fixed prostheses supported by four NDIs seems to be a reliable treatment in the medium to long term

    Clinical reliability of complete-arch fixed prostheses supported by narrow-diameter implants to support complete-arch restorations

    Get PDF
    The aim of this study was to evaluate the clinical application of fixed screw-retained complete-arch rehabilitations supported by four narrow-diameter implants (NDIs). The records of patients treated with complete-arch prostheses screwed onto four NDIs treated with an immediate loading protocol between 2010 and 2020 with at least 1 year of follow-up after the positioning of the definitive restoration were reviewed. The implants were placed according to the final prosthetic design and were immediately loaded. The interim prostheses were replaced after the healing period by definitive acrylic resin titanium-supported prostheses. Patients were followed to evaluate treatment success, the implant survival rate (ISR), and the prosthetic survival rate (PSR). A total of 121 NDIs were positioned in 30 patients to restore 30 complete arches (18 maxilla and 12 mandible). One implant did not achieve osseointegration, resulting in an overall ISR of 99.2%. No prosthetic or implant failures occurred during the 1 to 11 years of follow-up. Three biological and four prosthetic complications occurred, resulting in a treatment rehabilitation survival of 94.1% and a PSR of 86.7%. Despite the limitations of the present retrospective study, such as the use of one single type of dental implant and patients treated in a single rehabilitation center, complete-arch rehabilitation with fixed prostheses supported by four NDIs seems to be a reliable treatment in the medium to long term

    Ecology of active and passive players and their impact on information selection

    Full text link
    Is visitors' attendance a fair indicator of a web site's quality? Internet sub-domains are usually characterized by power law distributions of visits, thus suggesting a richer-get-richer process. If this is the case, the number of visits is not a relevant measure of quality. If, on the other hand, there are active players, i.e. visitors who can tell the value of the information available, better sites start getting richer after a crossover time.Comment: Accepted for publication on Phisica

    Recommendation model based on opinion diffusion

    Get PDF
    Information overload in the modern society calls for highly efficient recommendation algorithms. In this letter we present a novel diffusion based recommendation model, with users' ratings built into a transition matrix. To speed up computation we introduce a Green function method. The numerical tests on a benchmark database show that our prediction is superior to the standard recommendation methods.Comment: 5 pages, 2 figure

    Information filtering via Iterative Refinement

    Get PDF
    With the explosive growth of accessible information, expecially on the Internet, evaluation-based filtering has become a crucial task. Various systems have been devised aiming to sort through large volumes of information and select what is likely to be more relevant. In this letter we analyse a new ranking method, where the reputation of information providers is determined self-consistently.Comment: 10 pages, 3 figures. Accepted for publication on Europhysics Letter

    Immediate vs. delayed placement of immediately provisionalized self-tapping implants: a non-randomized controlled clinical trial with 1 year of follow-up

    Get PDF
    This study aimed to examine the clinical and esthetic outcomes of immediately provisionalized self-tapping implants placed in extraction sockets or healed edentulous ridges one year after treatment. Sixty patients in need of a single implant-supported restoration were treated with self-tapping implants (Straumann BLX) and immediate provisionalization. The implant stability quotient (ISQ) and insertion torque were recorded intraoperatively. After one year in function, the implant and prosthesis survival rate, pink esthetic score (PES), white esthetic score (WES), and marginal bone levels (MBL) were assessed. Sixty patients received 60 self-tapping implants. A total of 37 implants were placed in extraction sockets and 23 in edentulous ridges, and then all implants were immediately provisionalized. All implants achieved a high implant stability with a mean insertion torque and ISQ value of 58.1 ± 14.1 Ncm and 73.6 ± 8.1 Ncm, respectively. No significant differences were found between healed vs. post-extractive sockets (p = 0.716 and p = 0.875), or between flap vs. flapless approaches (p = 0.862 and p = 0.228) with regards to the insertion torque and ISQ value. Nonetheless, higher insertion torque values and ISQs were recorded for mandibular implants (maxilla vs. mandible, insertion torque: 55.30 + 11.25 Ncm vs. 62.41 + 17.01 Ncm, p = 0.057; ISQ: 72.05 + 8.27 vs. 76.08 + 7.37, p = 0.058). One implant did not osseointegrate, resulting in an implant survival rate of 98.3%. All implants achieved PES and WES scores higher than 12 at the 1-year follow-up. The clinical use of newly designed self-tapping implants with immediate temporization was safe and predictable. The implants achieved a good primary stability, high implant survival rate, and favorable radiographic and esthetic outcomes, regardless of the immediate or delayed placement protocols

    Advanced documentation methodologies combined with multi-analytical approach for the preservation and restoration of 18th century architectural decorative elements at Palazzo Nuzzi in Orte (Central Italy)

    Get PDF
    This contribution reports the documentation of the conservation status and the pictorial technique of a wall painting and a stucco arch at Palazzo Nuzzi in Orte, central Italy (Viterbo district), achieved using a wide combination of non-invasive and micro-invasive diagnostic techniques. Specifically, a photogrammetric approach has been used for 2D and 3D ultraviolet fluorescence (UVF) acquisitions. Moreover, the conservation status of the wall painting has been also investigated by a non-invasive active infrared thermograghy technique, i.e. Pulse Compression Thermography (PuCT), used here for the first time on a wall painting to map the surface and sub-surface cracks in the first layers. Pigments, grounds and organic binders were characterised by X-ray fluorescence spectroscopy, micro-stratigraphic analysis, Fourier transform infrared spectroscopy and gas chromatography coupled with mass spectrometry. The results of this unique combination of advanced tools corroborated the historical-artistic attribution to the school of the architect Andrea Pozzo

    The effect of discrete vs. continuous-valued ratings on reputation and ranking systems

    Full text link
    When users rate objects, a sophisticated algorithm that takes into account ability or reputation may produce a fairer or more accurate aggregation of ratings than the straightforward arithmetic average. Recently a number of authors have proposed different co-determination algorithms where estimates of user and object reputation are refined iteratively together, permitting accurate measures of both to be derived directly from the rating data. However, simulations demonstrating these methods' efficacy assumed a continuum of rating values, consistent with typical physical modelling practice, whereas in most actual rating systems only a limited range of discrete values (such as a 5-star system) is employed. We perform a comparative test of several co-determination algorithms with different scales of discrete ratings and show that this seemingly minor modification in fact has a significant impact on algorithms' performance. Paradoxically, where rating resolution is low, increased noise in users' ratings may even improve the overall performance of the system.Comment: 6 pages, 2 figure
    • …
    corecore