895 research outputs found

    Fire Propagation Performance of Intumescent Fire Protective Coatings Using Eggshells as a Novel Biofiller

    Get PDF
    This paper aims to synthesize and characterize an effective intumescent fire protective coating that incorporates eggshell powder as a novel biofiller. The performances of thermal stability, char formation, fire propagation, water resistance, and adhesion strength of coatings have been evaluated. A few intumescent flame-retardant coatings based on these three ecofriendly fire retardant additives ammonium polyphosphate phase II, pentaerythritol and melamine mixed together with flame-retardant fillers, and acrylic binder have been prepared and designed for steel. The fire performance of the coatings has conducted employing BS 476: Part 6-Fire propagation test. The foam structures of the intumescent coatings have been observed using field emission scanning electron microscopy. On exposure, the coated specimens’ B, C, and D had been certified to be Class 0 due to the fact that their fire propagation indexes were less than 12. Incorporation of ecofriendly eggshell, biofiller into formulation D led to excellent performance in fire stopping (index value, (I)=4.3) and antioxidation of intumescent coating. The coating is also found to be quite effective in water repellency, uniform foam structure, and adhesion strength

    Retinal Changes in a Mutant Form of Goldfish with Megalophthalmia

    Get PDF
    The retinal changes of a mutant strain of goldfish with megalophthalmia were studied by histology, electron microscopy and biochemistry. Changes in the morphology of the pigment epithelium, decrease in number of photoreceptors, thinning out of retinal layers and the existence of spaces in the retina were all features as the eyes grew in size. Invasion of macrophages was also evident in the retina. A decrease in leucine uptake per milligram of retina was also detected as the eye grew beyond 0.8 millilitre in volume. These changes, although related to volume changes (i.e., growth) of the eyes, were found to have little relationship with increase of intraocular pressure as intraocular pressures in the growing eyes of the mutant strain did not change much. Goldfish from a control strain with similar eye volumes and sizes (ages) were used for comparison and similar changes as in the mutant were not apparent

    Utilization of a novel digital measurement tool for quantitative assessment of upper extremity motor dexterity: a controlled pilot study.

    Get PDF
    BackgroundThe current methods of assessing motor function rely primarily on the clinician's judgment of the patient's physical examination and the patient's self-administered surveys. Recently, computerized handgrip tools have been designed as an objective method to quantify upper-extremity motor function. This pilot study explores the use of the MediSens handgrip as a potential clinical tool for objectively assessing the motor function of the hand.MethodsEleven patients with cervical spondylotic myelopathy (CSM) were followed for three months. Eighteen age-matched healthy participants were followed for two months. The neuromotor function and the patient-perceived motor function of these patients were assessed with the MediSens device and the Oswestry Disability Index respectively. The MediSens device utilized a target tracking test to investigate the neuromotor capacity of the participants. The mean absolute error (MAE) between the target curve and the curve tracing achieved by the participants was used as the assessment metric. The patients' adjusted MediSens MAE scores were then compared to the controls. The CSM patients were further classified as either "functional" or "nonfunctional" in order to validate the system's responsiveness. Finally, the correlation between the MediSens MAE score and the ODI score was investigated.ResultsThe control participants had lower MediSens MAE scores of 8.09%±1.60%, while the cervical spinal disorder patients had greater MediSens MAE scores of 11.24%±6.29%. Following surgery, the functional CSM patients had an average MediSens MAE score of 7.13%±1.60%, while the nonfunctional CSM patients had an average score of 12.41%±6.32%. The MediSens MAE and the ODI scores showed a statistically significant correlation (r=-0.341, p<1.14×10⁻⁵). A Bland-Altman plot was then used to validate the agreement between the two scores. Furthermore, the percentage improvement of the the two scores after receiving the surgical intervention showed a significant correlation (r=-0.723, p<0.04).ConclusionsThe MediSens handgrip device is capable of identifying patients with impaired motor function of the hand. The MediSens handgrip scores correlate with the ODI scores and may serve as an objective alternative for assessing motor function of the hand

    Study on the energy scavenging from household air conditioning unit

    Get PDF
    This paper presents the design and construction of an energy scavenging system from a household air conditioning unit. The scavenged energy is used to heat up water for domestic purposes. The system consists of the condenser of a household air conditioning unit (existing), a pump, a plate heat exchanger, and a hot water storage tank. The condenser unit of a household air conditioner is modified to enable the flow of hot compressed refrigerant coming out from the compressor through the plate heat exchanger. The superheated portion of the heat is continuously absorbed by the water inside the hot water storage tank. Experimental investigation showed that this system can heat up water from room temperature to 82ºC within 9 hours of operation (8:00 am to 5:00 pm). By using this type of energy scavenging device, compressor efficiency can be improved and at the same time, hot water for domestic purposes can continuously be obtained free of charge. The end result is faster cooling and prolonged compressor life. This system is simple yet affordable and able to save water heating cost and environment friendly, i.e., less heat is rejected to the environment

    Higher-order nonlinear modes and bifurcation phenomena due to degenerate parametric four-wave mixing

    Get PDF
    We demonstrate that weak parametric interaction of a fundamental beam with its third harmonic field in Kerr media gives rise to a rich variety of families of non-fundamental (multi-humped) solitary waves. Making a comprehensive comparison between bifurcation phenomena for these families in bulk media and planar waveguides, we discover two novel types of soliton bifurcations and other interesting findings. The later includes (i) multi-humped solitary waves without even or odd symmetry and (ii) multi-humped solitary waves with large separation between their humps which, however, may not be viewed as bound states of several distinct one-humped solitons.Comment: 9 pages, 17 figures, submitted to Phys. Rev.

    Eradication of large solid tumors by gene therapy with a T cell receptor targeting a single cancer-specific point mutation

    Get PDF
    PURPOSE: Cancers usually contain multiple unique tumor-specific antigens produced by single amino acid substitutions (AAS) and encoded by somatic non-synonymous single nucleotide substitutions. We determined whether adoptively transferred T cells can reject large, well-established solid tumors when engineered to express a single type of T cell receptor (TCR) that is specific for a single AAS. EXPERIMENTAL DESIGN: By exome and RNA sequencing of an UV-induced tumor, we identified an AAS in p68 (mp68), a co-activator of p53. This AAS seemed to be an ideal tumor-specific neoepitope because it is encoded by a trunk mutation in the primary autochthonous cancer and binds with highest affinity to the MHC. A high-avidity mp68-specific TCR was used to genetically engineer T cells as well as to generate TCR-transgenic mice for adoptive therapy. RESULTS: When the neoepitope was expressed at high levels and by all cancer cells, their direct recognition sufficed to destroy intra-tumor vessels and eradicate large, long-established solid tumors. When the neoepitope was targeted as autochthonous antigen, T cells caused cancer regression followed by escape of antigen-negative variants. Escape could be thwarted by expressing the antigen at increased levels in all cancer cells or by combining T cell therapy with local irradiation. Therapeutic efficacies of TCR-transduced and TCR-transgenic T cells were similar. CONCLUSIONS: Gene therapy with a single TCR targeting a single AAS can eradicate large established cancer but a uniform expression and/or sufficient levels of the targeted neoepitope or additional therapy are required to overcome tumor escape

    The future of enterprise groupware applications

    Get PDF
    This paper provides a review of groupware technology and products. The purpose of this review is to investigate the appropriateness of current groupware technology as the basis for future enterprise systems and evaluate its role in realising, the currently emerging, Virtual Enterprise model for business organisation. It also identifies in which way current technological phenomena will transform groupware technology and will drive the development of the enterprise systems of the future

    Utilization of a novel digital measurement tool for quantitative assessment of upper extremity motor dexterity: a controlled pilot study

    Get PDF
    BACKGROUND: The current methods of assessing motor function rely primarily on the clinician’s judgment of the patient’s physical examination and the patient’s self-administered surveys. Recently, computerized handgrip tools have been designed as an objective method to quantify upper-extremity motor function. This pilot study explores the use of the MediSens handgrip as a potential clinical tool for objectively assessing the motor function of the hand. METHODS: Eleven patients with cervical spondylotic myelopathy (CSM) were followed for three months. Eighteen age-matched healthy participants were followed for two months. The neuromotor function and the patient-perceived motor function of these patients were assessed with the MediSens device and the Oswestry Disability Index respectively. The MediSens device utilized a target tracking test to investigate the neuromotor capacity of the participants. The mean absolute error (MAE) between the target curve and the curve tracing achieved by the participants was used as the assessment metric. The patients’ adjusted MediSens MAE scores were then compared to the controls. The CSM patients were further classified as either “functional” or “nonfunctional” in order to validate the system’s responsiveness. Finally, the correlation between the MediSens MAE score and the ODI score was investigated. RESULTS: The control participants had lower MediSens MAE scores of 8.09%±1.60%, while the cervical spinal disorder patients had greater MediSens MAE scores of 11.24%±6.29%. Following surgery, the functional CSM patients had an average MediSens MAE score of 7.13%±1.60%, while the nonfunctional CSM patients had an average score of 12.41%±6.32%. The MediSens MAE and the ODI scores showed a statistically significant correlation (r=-0.341, p<1.14×10(-5)). A Bland-Altman plot was then used to validate the agreement between the two scores. Furthermore, the percentage improvement of the the two scores after receiving the surgical intervention showed a significant correlation (r=-0.723, p<0.04). CONCLUSIONS: The MediSens handgrip device is capable of identifying patients with impaired motor function of the hand. The MediSens handgrip scores correlate with the ODI scores and may serve as an objective alternative for assessing motor function of the hand. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/1743-0003-11-121) contains supplementary material, which is available to authorized users

    Longitudinal grey and white matter changes in frontotemporal dementia and Alzheimer's disease

    Get PDF
    Behavioural variant frontotemporal dementia (bvFTD) and Alzheimer's disease (AD) dementia are characterised by progressive brain atrophy. Longitudinal MRI volumetry may help to characterise ongoing structural degeneration and support the differential diagnosis of dementia subtypes. Automated, observer-independent atlas-based MRI volumetry was applied to analyse 102 MRI data sets from 15 bvFTD, 14 AD, and 10 healthy elderly control participants with consecutive scans over at least 12 months. Anatomically defined targets were chosen a priori as brain structures of interest. Groups were compared regarding volumes at clinic presentation and annual change rates. Baseline volumes, especially of grey matter compartments, were significantly reduced in bvFTD and AD patients. Grey matter volumes of the caudate and the gyrus rectus were significantly smaller in bvFTD than AD. The bvFTD group could be separated from AD on the basis of caudate volume with high accuracy (79% cases correct). Annual volume decline was markedly larger in bvFTD and AD than controls, predominantly in white matter of temporal structures. Decline in grey matter volume of the lateral orbitofrontal gyrus separated bvFTD from AD and controls. Automated longitudinal MRI volumetry discriminates bvFTD from AD. In particular, greater reduction of orbitofrontal grey matter and temporal white matter structures after 12 months is indicative of bvFTD
    corecore