1,149 research outputs found

    Strong Discontinuities in the Complex Photonic Band Structure of Transmission Metallic Gratings

    Get PDF
    Complex photonic band structures (CPBS) of transmission metallic gratings with rectangular slits are shown to exhibit strong discontinuities that are not evidenced in the usual energetic band structures. These discontinuities are located on Wood's anomalies and reveal unambiguously two different types of resonances, which are identified as horizontal and vertical surface-plasmon resonances. Spectral position and width of peaks in the transmission spectrum can be directly extracted from CPBS for both kinds of resonances.Comment: 4 pages, 4 figures, REVTeX version

    Reliability of an integrated ultrasound and stereophotogrammetric system for lower limb anatomical characterisation

    Get PDF
    Background. Lower extremity analysis for preoperative total knee and hip arthroplasty routines can increase surgery success rate and hence reduce associated costs. Current tools are limited by being invasive, limited to supine analysis, or too expensive. This study aimed to propose and validate a device, OrthoPilotŸ, based on the combined use of a stereophotogrammetric and ultrasound system which can in vivo and noninvasively measure varus/valgus, flexion/extension, femur and tibia torsion, and femur and tibia lengths. Methods. A phantom was measured by four operators to determine the resolution of the system. Interoperator variability was measured on three operators who measured the above six variables on both legs of three subjects in standing and supine positions. Intraoperator variability was assessed on data from three repeats from 9 subjects (18 legs). Results. All 6 variables were reliably detected on a phantom, with a resolution of 1 mm and 0.5° . Inter- and intraoperator consistency was observed for varus/valgus, flexion/extension, and length measurements on the healthy subjects in standing and supine positions (all ICC > 0.93). For torsion measurements, there was a considerable variation. Conclusion. The proposed system, when used on healthy subjects, allowed reliable measurements of key parameters for preoperative procedures in both supine and standing positions. Accuracy testing and further validation on patient populations will be the next step toward its clinical adoption

    Collective Feshbach scattering of a superfluid droplet from a mesoscopic two-component Bose-Einstein condensate

    Full text link
    We examine the collective scattering of a superfluid droplet impinging on a mesoscopic Bose-Einstein condensate (BEC) as a target. The BEC consists of an atomic gas with two internal electronic states, each of which is trapped by a finite-depth external potential. An off-resonant optical laser field provides a localized coupling between the BEC components in the trapping region. This mesoscopic scenario matches the microscopic setup for Feshbach scattering of two particles, when a bound state of one sub-manifold is embedded in the scattering continuum of the other sub-manifold. Within the mean-field picture, we obtain resonant scattering phase shifts from a linear response theory in agreement with an exact numerical solution of the real time scattering process and simple analytical approximations thereof. We find an energy-dependent transmission coefficient that is controllable via the optical field between 0 and 100%.Comment: 4 Latex pages, including 4 figure

    Histopathological Analysis of PEEK Wear Particle Effects on the Synovial Tissue of Patients

    Get PDF
    Introduction. Increasing interest developed in the use of carbon-fiber-reinforced-poly-ether-ether-ketones (CFR-PEEK) as an alternative bearing material in knee arthroplasty. The effects of CFR-PEEK wear in in vitro and animal studies are controversially discussed, as there are no data available concerning human tissue. The aim of this study was to analyze human tissue containing CFR-PEEK as well as UHMWPE wear debris. The authors hypothesized no difference between the used biomaterials. Methods and Materials. In 10 patients during knee revision surgery of a rotating-hinge-knee-implant-design, synovial tissue samples were achieved (tibial inserts: UHMWPE;bushings and flanges: CFR-PEEK). One additional patient received revision surgery without any PEEK components as a control. The tissue was paraffin-embedded, sliced into 2 mu m thick sections, and stained with hematoxylin and eosin in a standard process. A modified panoptical staining was also done. Results. A "wear-type" reaction was seen in the testing and the control group. In all samples, the UHMWPE particles were scattered in the tissue or incorporated in giant cells. CFR-PEEK particles were seen as conglomerates and only could be found next to vessels. CFR-PEEK particles showed no giant-cell reactions. In conclusion, the hypothesis has to be rejected. UHMWPE and PEEK showed a different scatter-behavior in human synovial tissue

    Molecular confirmation of species status for the allopolyploid cotton species, Gossypium ekmanianum Wittmack.

    Get PDF
    Understanding the relationship between domesticated crop species and their wild relatives is paramount to germplasm maintenance and the utilization of wild relatives in breeding programs. Recently, Gossypium ekmanianum was resurrected as an independent species based on morphological analysis of specimens obtained from the Dominican Republic, where the original type specimen was collected. The molecular data presented here support the recognition of G. ekmanianum Wittmack as a distinct species that is phylogenetically close to G. hirsutum L. Analyses of chloroplast DNA data reveal species-specific, indel polymorphisms that unambiguously distinguish G. ekmanianum samples from other polyploid congeners. Furthermore, analysis of accessions that originated from the Dominican Republic demonstrate the cryptic inclusion of this sister taxon within the US National Plant Germplasm System, a germplasm collection maintained for diversity preservation and future breeding resources. The data presented here indicate that ‘‘wild’’ G. hirsutum accessions may include the closely related G. ekmanianum, and provide a method to easily distinguish the two.Fil: Grover, C. E.. University of Iowa; Estados UnidosFil: Zhu, X.. Nantong University; ChinaFil: Grupp, K. K.. University Of Iowa; Estados UnidosFil: Jareczek, J. J.. University of Iowa; Estados UnidosFil: J. P. Gallagher. University of Iowa; Estados UnidosFil: Szadkowski, E.. University of Iowa; Estados UnidosFil: Seijo, Jose Guillermo. Consejo Nacional de Investigaciones CientĂ­ficas y TĂ©cnicas. Centro CientĂ­fico TecnolĂłgico Nordeste. Instituto de BotĂĄnica del Nordeste (i); Argentina. Universidad Nacional del Nordeste. Facultad de Ciencias Exactas Naturales y Agrimensura; ArgentinaFil: Wendel, J. F.. University of Iowa; Estados Unido

    Patient-specific finite element models of posterior pedicle screw fixation : effect of screw’s size and geometry

    Get PDF
    Pedicle screw fixation is extensively performed to treat spine injuries or diseases and it is common for thoracolumbar fractures. Post-operative complications may arise from this surgery leading to back pain or revisions. Finite element (FE) models could be used to predict the outcomes of surgeries but should be verified when both simplified and realistic designs of screws are used. The aim of this study was to generate patient-specific Computed Tomography (CT)-based FE models of human vertebrae with two pedicle screws, verify the models, and use them to evaluate the effect of the screws’ size and geometry on the mechanical properties of the screws-vertebra structure. FE models of the lumbar vertebra implanted with two pedicle screws were created from anonymized CT-scans of three patients. Compressive loads were applied to the head of the screws. The mesh size was optimized for realistic and simplified geometry of the screws with a mesh refinement study. Finally, the optimal mesh size was used to evaluate the sensitivity of the model to changes in screw’s size (diameter and length) and geometry (realistic or simplified). For both simplified and realistic models, element sizes of 0.6 mm in the screw and 1.0 mm in the bone allowed to obtain relative differences of approximately 5% or lower. Changes in screw’s length resulted in 4–10% differences in maximum deflection, 1–6% differences in peak stress in the screws, 10–22% differences in mean strain in the bone around the screw; changes in screw’s diameter resulted in 28–36% differences in maximum deflection, 6–27% differences in peak stress in the screws, and 30–47% differences in mean strain in the bone around the screw. The maximum deflection predicted with realistic or simplified screws correlated very well (R2 = 0.99). The peak stress in screws with realistic or simplified design correlated well (R2 = 0.82) but simplified models underestimated the peak stress. In conclusion, the results showed that the diameter of the screw has a major role on the mechanics of the screw-vertebral structure for each patient. Simplified screws can be used to estimate the mechanical properties of the implanted vertebrae, but the systematic underestimation of the peak stress should be considered when interpreting the results from the FE analyses

    Anomalous Hopping Exponents of Ultrathin Films of Metals

    Full text link
    The temperature dependence of the resistance R(T) of ultrathin quench-condensed films of Ag, Bi, Pb and Pd has been investigated. In the most resistive films, R(T)=Roexp(To/T)^x, where x=0.75. Surprisingly, the exponent x was found to be constant for a wide range of Ro and To in all four materials, possibly implying a consistent underlying conduction mechanism. The results are discussed in terms of several different models of hopping conduction.Comment: 6 pages, 5 figure

    Positron lifetime measurements on neutron‐irradiated InP crystals

    Get PDF
    Neutron‐irradiated InP single crystals have been investigated by positron‐lifetime measurements. The samples were irradiated with thermal neutrons at different fluences yielding concentrations for Sn‐transmuted atoms between 2×1015 and 2×1018 cm−3. The lifetime spectra have been analyzed into one exponential decay component. The mean lifetimes show a monotonous increase with the irradiation dose from 246 to 282 ps. The increase in the lifetime has been associated to a defect containing an Indium vacancy. Thermal annealing at 550 °C reduces the lifetime until values closed to those obtained for the as‐grown and conventionally doped InP [email protected] ; [email protected]
    • 

    corecore