476 research outputs found

    Current distribution in a parallel configuration superconducting strip-line detector

    Get PDF
    Superconducting detectors based on parallel microscopic strip-lines are promising candidates for single molecule detection in time-of-flight mass spectrometry. The device physics of this configuration is complex. In this letter, we employ nano-optical techniques to study the variation of current density, count rate, and pulse amplitude transversely across the parallel strip device. Using the phenomenological London theory, we are able to correlate our results to a non-uniform current distribution between the strips, governed by the London magnetic penetration depth. This fresh perspective convincingly explains anomalous behaviour in large area parallel superconducting strip-line detectors reported in previous studies

    Control of bulk superconductivity in a BCS superconductor by surface charge doping via electrochemical gating

    Get PDF
    The electrochemical gating technique is a powerful tool to tune the surface conduction properties of various materials by means of pure charge doping, but its efficiency is thought to be hampered in materials with a good electronic screening. We show that, if applied to a metallic superconductor (NbN thin films), this approach allows observing reversible enhancements or suppressions of the bulk superconducting transition temperature, which vary with the thickness of the films. These results are interpreted in terms of proximity effect, and indicate that the effective screening length depends on the induced charge density, becoming much larger than that predicted by standard screening theory at very high electric fields

    Reliability and Physiological Interpretation of Pulmonary Gas Exchange by "Circulatory Equivalents" in Chronic Heart Failure

    Get PDF
    Peak ratios of pulmonary gas-exchange to ventilation during exercise (V˙O2/V˙E and V˙CO2/V˙E, termed "circulatory equivalents") are sensitive to heart failure (HF) severity, likely reflecting low and/or poorly distributed pulmonary perfusion. We tested whether peak V˙O2/V˙E and V˙CO2/V˙E would: (1) distinguish HF patients from controls; (2) be independent of incremental exercise protocol; and (3) correlate with lactate threshold (LT) and ventilatory compensation point (VCP), respectively.Twenty-four HF patients (61±11 years) with reduced ejection fraction (31±8%) and 11 controls (63±7 years) performed ramp-incremental cycle ergometry. Eighteen HF patients also performed slow (5±1 W/min), medium (9±4 W/min), and fast (19±6 W/min) ramps. Peak V˙O2/V˙E and V˙CO2/V˙E from X-Y plot, and LT and VCP from 9-panel plot, were determined by 2 independent, blinded, assessors. Peak V˙O2/V˙E (31.2±4.4 versus 41.8±4.8 mL/L; P<0.0001) and V˙CO2/V˙E (29.3±3.0 versus 36.9±4.0 mL/L; P<0.0001) were lower in HF than controls. Within individuals, there was no difference across 3 ramp rates in peak V˙O2/V˙E (P=0.62) or V˙CO2/V˙E (P=0.97). Coefficient of variation (CV) in peak V˙O2/V˙E was lower than for LT (5.1±2.1% versus 8.2±3.7%; P=0.014), and coefficient of variation in peak V˙CO2/V˙E was lower than for VCP (3.3±1.8% versus 8.7±4.2%; P<0.001). In all participants, peak V˙O2/V˙E was correlated with, but occurred earlier than, LT (r2=0.94; mean bias, -0.11 L/min), and peak V˙CO2/V˙E was correlated with, but occurred earlier than, VCP (r2=0.98; mean bias -0.08 L/min).Peak circulatory equivalents during exercise are strongly associated with (but not identical to) LT and VCP. Peak circulatory equivalents are reliable, objective, effort-independent indices of gas-exchange abnormality in HF

    Participation in contract farming and farm performance: Insights from cashew farmers in Ghana

    Get PDF
    The global demand for cashew nuts continues to increase steadily. However, many African countries face difficulties in marketing and adding value to the product. Using recent survey data of 391 cashew farmers in Ghana, this paper contributes to the grow- ing evidence on the significance of contract farming (CF) in improving the welfare of rural households in developing countries. Specifically, the paper analyzes the fac- tors that influence cashew farmers’ decisions to participate in CF, and the impact of participation on farmers’ performance. We employ a recently developed switch- ing regression model with endogenous explanatory variables and endogenous switch- ing to control for selection bias caused by observable and unobservable factors. The empirical results show that participation in CF significantly increases labor produc- tivity and price margins, as well as cashew yields, and net revenues. A disaggregated analysis of the sample into farm size categories reveals that small-sized cashew farms tend to benefit more through CF, compared to medium- and large-sized farms

    Persistence of Supplemented Bifidobacterium longum subsp. infantis EVC001 in Breastfed Infants.

    Get PDF
    Attempts to alter intestinal dysbiosis via administration of probiotics have consistently shown that colonization with the administered microbes is transient. This study sought to determine whether provision of an initial course of Bifidobacterium longum subsp. infantis (B.&nbsp;infantis) would lead to persistent colonization of the probiotic organism in breastfed infants. Mothers intending to breastfeed were recruited and provided with lactation support. One group of mothers fed B.&nbsp;infantis EVC001 to their infants from day 7 to day 28 of life (n = 34), and the second group did not administer any probiotic (n = 32). Fecal samples were collected during the first 60&nbsp;postnatal days in both groups. Fecal samples were assessed by 16S rRNA gene sequencing, quantitative PCR, mass spectrometry, and endotoxin measurement. B.&nbsp;infantis-fed infants had significantly higher populations of fecal Bifidobacteriaceae, in particular B.&nbsp;infantis, while EVC001 was fed, and this difference persisted more than 30&nbsp;days after EVC001 supplementation ceased. Fecal milk oligosaccharides were significantly lower in B.&nbsp;infantis EVC001-fed infants, demonstrating higher consumption of human milk oligosaccharides by B. infantis EVC001. Concentrations of acetate and lactate were significantly higher and fecal pH was significantly lower in infants fed EVC001, demonstrating alterations in intestinal fermentation. Infants colonized by Bifidobacteriaceae at high levels had 4-fold-lower fecal endotoxin levels, consistent with observed lower levels of Gram-negative Proteobacteria and Bacteroidetes. IMPORTANCE The gut microbiome in early life plays an important role for long-term health and is shaped in large part by diet. Probiotics may contribute to improvements in health, but they have not been shown to alter the community composition of the gut microbiome. Here, we found that breastfed infants could be stably colonized at high levels by provision of B.&nbsp;infantis EVC001, with significant changes to the overall microbiome composition persisting more than a month later, whether the infants were born vaginally or by caesarean section. This observation is consistent with previous studies demonstrating the capacity of this subspecies to utilize human milk glycans as a nutrient and underscores the importance of pairing a probiotic organism with a specific substrate. Colonization by B.&nbsp;infantis EVC001 resulted in significant changes to fecal microbiome composition and was associated with improvements in fecal biochemistry. The combination of human milk and an infant-associated Bifidobacterium sp. shows, for the first time, that durable changes to the human gut microbiome are possible and are associated with improved gut function

    Overstating the evidence - double counting in meta-analysis and related problems

    Get PDF
    Background: The problem of missing studies in meta-analysis has received much attention. Less attention has been paid to the more serious problem of double counting of evidence. Methods: Various problems in overstating the precision of results from meta-analyses are described and illustrated with examples, including papers from leading medical journals. These problems include, but are not limited to, simple double-counting of the same studies, double counting of some aspects of the studies, inappropriate imputation of results, and assigning spurious precision to individual studies. Results: Some suggestions are made as to how the quality and reliability of meta-analysis can be improved. It is proposed that the key to quality in meta-analysis lies in the results being transparent and checkable. Conclusions: Existing quality check lists for meta-analysis do little to encourage an appropriate attitude to combining evidence and to statistical analysis. Journals and other relevant organisations should encourage authors to make data available and make methods explicit. They should also act promptly to withdraw meta-analyses when mistakes are found

    Superconducting nano-strip particle detectors

    Full text link
    We review progress in the development and applications of superconducting nano-strip particle detectors. Particle detectors based on superconducting nano-strips stem from the parent devices developed for single photon detection (SSPD) and share with them ultra-fast response times (sub-nanosecond) and the ability to operate at a relatively high temperature (2–5 K) compared with other cryogenic detectors. SSPDs have been used in the detection of electrons, neutral and charged ions, and biological macromolecules; nevertheless, the development of superconducting nano-strip particle detectors has mainly been driven by their use in time-of-flight mass spectrometers (TOF-MSs) where the goal of 100% efficiency at large mass values can be achieved. Special emphasis will be given to this case, reporting on the great progress which has been achieved and which permits us to overcome the limitations of existing mass spectrometers represented by low detection efficiency at large masses and charge/mass ambiguity. Furthermore, such progress could represent a breakthrough in the field. In this review article we will introduce the device concept and detection principle, stressing the peculiarities of the nano-strip particle detector as well as its similarities with photon detectors. The development of parallel strip configuration is introduced and extensively discussed, since it has contributed to the significant progress of TOF-MS applications

    Relationship between FEV1 change and patient-reported outcomes in randomised trials of inhaled bronchodilators for stable COPD: a systematic review.

    Get PDF
    BACKGROUND: Interactions between spirometry and patient-reported outcomes in COPD are not well understood. This systematic review and study-level analysis investigated the relationship between changes in FEV1 and changes in health status with bronchodilator therapy. METHODS: Six databases (to October 2009) were searched to identify studies with long-acting bronchodilator therapy reporting FEV1 and health status, dyspnoea or exacerbations. Mean and standard deviations of treatment effects were extracted for each arm of each study. Relationships between changes in trough FEV1 and outcomes were assessed using correlations and random-effects regression modelling. The primary outcome was St George's Respiratory Questionnaire (SGRQ) total score. RESULTS: Thirty-six studies (≥ 3 months) were included. Twenty-two studies (23,654 patients) with 49 treatment arms each contributing one data point provided SGRQ data. Change in trough FEV1 and change in SGRQ total score were negatively correlated (r = -0.46, p < 0.001); greater increases in FEV1 were associated with greater reductions (improvements) in SGRQ. The correlation strengthened with increasing study duration from 3 to 12 months. Regression modelling indicated that 100 mL increase in FEV1 (change at which patients are more likely to report improvement) was associated with a statistically significant reduction in SGRQ of 2.5 (95% CI 1.9, 3.1), while a clinically relevant SGRQ change (4.0) was associated with 160.6 (95% CI 129.0, 211.6) mL increase in FEV1. The association between change in FEV1 and other patient-reported outcomes was generally weak. CONCLUSIONS: Our analyses indicate, at a study level, that improvement in mean trough FEV1 is associated with proportional improvements in health status

    Elevated Fecal pH Indicates a Profound Change in the Breastfed Infant Gut Microbiome Due to Reduction of \u3ci\u3eBifidobacterium\u3c/i\u3e over the Past Century

    Get PDF
    Historically, Bifidobacterium species were reported as abundant in the breastfed infant gut. However, recent studies in resource-rich countries show an increased abundance of taxa regarded as signatures of dysbiosis. It is unclear whether these differences are the product of genetics, geographic factors, or interventions such as formula feeding, antibiotics, and caesarean section. Fecal pH is strongly associated with Bifidobacterium abundance; thus, pH could be an indicator of its historical abundance. A review of 14 clinical studies published between 1926 and 2017, representing more than 312 healthy breastfed infants, demonstrated a change in fecal pH from 5.0 to 6.5 (adjusted r2 = 0.61). This trend of increasing infant fecal pH over the past century is consistent with current reported discrepancies in Bifidobacterium species abundance in the gut microbiome in resource-rich countries compared to that in historical reports. Our analysis showed that increased fecal pH and abundance of members of the families Enterobacteriaceae, Clostridiaceae, Peptostreptococcaceae, and Veillonellaceae are associated, indicating that loss of highly specialized Bifidobacterium species may result in dysbiosis, the implications of which are not yet fully elucidated. Critical assessment of interventions that restore this ecosystem, measured by key parameters such as ecosystem productivity, gut function, and long-term health, are necessary to understand the magnitude of this change in human biology over the past century
    • …
    corecore