68 research outputs found

    Monolithically integrated heterodyne optical phase-lock loop with RF XOR phase detector

    Get PDF
    We present results for an heterodyne optical phase-lock loop (OPLL), monolithically integrated on InP with external phase detector and loop filter, which phase locks the integrated laser to an external source, for offset frequencies tuneable between 0.6 GHz and 6.1 GHz. The integrated semiconductor laser emits at 1553 nm with 1.1 MHz linewidth, while the external laser has a linewidth less than 150 kHz. To achieve high quality phase locking with lasers of these linewidths, the loop delay has been made less than 1.8 ns. Monolithic integration reduces the optical path delay between the laser and photodiode to less than 20 ps. The electronic part of the OPLL was implemented using a custom-designed feedback circuit with a propagation delay of similar to 1 ns and an open-loop bandwidth greater than 1 GHz. The heterodyne signal between the locked slave laser and master laser has phase noise below. 90 dBc/Hz for frequency offsets greater than 20 kHz and a phase error variance in 10 GHz bandwidth of 0.04 rad(2). (C) 2011 Optical Society of Americ

    Falls screening and assessment tools used in acute mental health settings : A review of policies in England and Wales

    Get PDF
    V. Narayanan, et al, "Falls screening and assessment tools used in acute mental health settings: A review of policies in England and Wales", Physiotherapy, Vol. 102, Issue 2: 178-183, June 2016. © 2015 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).Objectives: There is an urgent need to improve the care of older people at risk of falls or who experience falls in mental health settings. The aims of this study were to evaluate the individual falls risk assessment tools adopted by National Health Service (NHS) mental health trusts in England and healthcare boards in Wales, to evaluate the comprehensiveness of these tools and to review their predictive validity. Methods: All NHS mental health trusts in England (n = 56) and healthcare boards in Wales (n = 6) were invited to supply their falls policies and other relevant documentation (e.g. local falls audits). In order to check the comprehensiveness of tools listed in policy documents, the risk variables of the tools adopted by the mental health trusts' policies were compared with the 2004 National Institute for Health and Care Excellence (NICE) falls prevention guidelines. A comprehensive analytical literature review was undertaken to evaluate the predictive validity of the tools used in these settings. Results: Falls policies were obtained from 46 mental health trusts. Thirty-five policies met the study inclusion criteria and were included in the analysis. The main falls assessment tools used were the St. Thomas' Risk Assessment Tool in Falling Elderly Inpatients (STRATIFY), Falls Risk Assessment Scale for the Elderly, Morse Falls Scale (MFS) and Falls Risk Assessment Tool (FRAT). On detailed examination, a number of different versions of the FRAT were evident; validated tools had inconsistent predictive validity and none of them had been validated in mental health settings. Conclusions: Falls risk assessment is the most commonly used component of risk prevention strategies, but most policies included unvalidated tools and even well validated tool such as the STRATIFY and the MFS that are reported to have inconsistent predictive accuracy. This raises questions about operational usefulness, as none of these tools have been tested in acute mental health settings. The falls risk assessment tools from only four mental health trusts met all the recommendations of the NICE falls guidelines on multifactorial assessment for prevention of falls. The recent NICE (2013) guidance states that tools predicting risk using numeric scales should no longer be used; however, multifactorial risk assessment and interventions tailored to patient needs is recommended. Trusts will need to update their policies in response to this guidance.Peer reviewedFinal Published versio

    VX Hydrolysis by Human Serum Paraoxonase 1: A Comparison of Experimental and Computational Results

    Get PDF
    Human Serum paraoxonase 1 (HuPON1) is an enzyme that has been shown to hydrolyze a variety of chemicals including the nerve agent VX. While wildtype HuPON1 does not exhibit sufficient activity against VX to be used as an in vivo countermeasure, it has been suggested that increasing HuPON1's organophosphorous hydrolase activity by one or two orders of magnitude would make the enzyme suitable for this purpose. The binding interaction between HuPON1 and VX has recently been modeled, but the mechanism for VX hydrolysis is still unknown. In this study, we created a transition state model for VX hydrolysis (VXts) in water using quantum mechanical/molecular mechanical simulations, and docked the transition state model to 22 experimentally characterized HuPON1 variants using AutoDock Vina. The HuPON1-VXts complexes were grouped by reaction mechanism using a novel clustering procedure. The average Vina interaction energies for different clusters were compared to the experimentally determined activities of HuPON1 variants to determine which computational procedures best predict how well HuPON1 variants will hydrolyze VX. The analysis showed that only conformations which have the attacking hydroxyl group of VXts coordinated by the sidechain oxygen of D269 have a significant correlation with experimental results. The results from this study can be used for further characterization of how HuPON1 hydrolyzes VX and design of HuPON1 variants with increased activity against VX.United States. Defense Threat Reduction Agenc

    Generation of continuous wave terahertz frequency radiation from metal-organic chemical vapour deposition grown Fe-doped InGaAs and InGaAsP

    Get PDF
    We demonstrate the generation of continuous wave terahertz (THz) frequency radiation from photomixers fabricated on both Fe-doped InGaAs and Fe-doped InGaAsP, grown by metal-organic chemical vapor deposition. The photomixers were excited using a pair of distributed Bragg reflector lasers with emission around 1550 nm, and THz radiation was emitted over a bandwidth of greater than 2.4 THz. Two InGaAs and four InGaAsP wafers with different Fe doping concentrations were investigated, with the InGaAsmaterial found to outperform the InGaAsP in terms of emitted THz power. The dependencies of the emitted power on the photomixer applied bias, incident laser power, and materialdoping level were also studied

    The Bank of Standardized Stimuli (BOSS), a New Set of 480 Normative Photos of Objects to Be Used as Visual Stimuli in Cognitive Research

    Get PDF
    There are currently stimuli with published norms available to study several psychological aspects of language and visual cognitions. Norms represent valuable information that can be used as experimental variables or systematically controlled to limit their potential influence on another experimental manipulation. The present work proposes 480 photo stimuli that have been normalized for name, category, familiarity, visual complexity, object agreement, viewpoint agreement, and manipulability. Stimuli are also available in grayscale, blurred, scrambled, and line-drawn version. This set of objects, the Bank Of Standardized Stimuli (BOSS), was created specifically to meet the needs of scientists in cognition, vision and psycholinguistics who work with photo stimuli

    Analysis of 339 pregnancies in 181 women with 13 different forms of inherited thrombocytopenia

    Get PDF
    65Pregnancy in women with inherited thrombocytopenias is a major matter of concern as both the mothers and the newborns are potentially at risk of bleeding. However, medical management of this condition cannot be based on evidence because of the lack of consistent information in the literature. To advance knowledge on this matter, we performed a multicentric, retrospective study evaluating 339 pregnancies in 181 women with 13 different forms of inherited thrombocytopenia. Neither the degree of thrombocytopenia nor the severity of bleeding tendency worsened during pregnancy and the course of pregnancy did not differ from that of healthy subjects in terms of miscarriages, fetal bleeding and pre-term births. The degree of thrombocytopenia in the babies was similar to that in the mother. Only 7 of 156 affected newborns had delivery-related bleeding, but 2 of them died of cerebral hemorrhage. The frequency of delivery-related maternal bleeding ranged from 6.8% to 14.2% depending on the definition of abnormal blood loss, suggesting that the risk of abnormal blood loss was increased with respect to the general population. However, no mother died or had to undergo hysterectomy to arrest bleeding. The search for parameters predicting delivery-related bleeding in the mother suggested that hemorrhages requiring blood transfusion were more frequent in women with history of severe bleedings before pregnancy and with platelet count at delivery below 50 × 10(9)/L.openopenPatrizia Noris; Nicole Schlegel; Catherine Klersy; Paula G. Heller; Elisa Civaschi; Nuria Pujol-Moix; Fabrizio Fabris; Remi Favier; Paolo Gresele; Véronique Latger-Cannard; Adam Cuker; Paquita Nurden; Andreas Greinacher; Marco Cattaneo; Erica De Candia; Alessandro Pecci; Marie-Françoise Hurtaud-Roux; Ana C. Glembotsky; Eduardo Muñiz-Diaz; Maria Luigia Randi; Nathalie Trillot; Loredana Bury; Thomas Lecompte; Caterina Marconi; Anna Savoia; Carlo L. Balduini; Sophie Bayart; Anne Bauters; Schéhérazade Benabdallah-Guedira; Françoise Boehlen; Jeanne-Yvonne Borg; Roberta Bottega; James Bussel; Daniela De Rocco; Emmanuel de Maistre; Michela Faleschini; Emanuela Falcinelli; Silvia Ferrari; Alina Ferster; Tiziana Fierro; Dominique Fleury; Pierre Fontana; Chloé James; Francois Lanza; Véronique Le Cam Duchez; Giuseppe Loffredo; Pamela Magini; Dominique Martin-Coignard; Fanny Menard; Sandra Mercier; Annamaria Mezzasoma; Pietro Minuz; Ilaria Nichele; Lucia D. Notarangelo; Tommaso Pippucci; Gian Marco Podda; Catherine Pouymayou; Agnes Rigouzzo; Bruno Royer; Pierre Sie; Virginie Siguret; Catherine Trichet; Alessandra Tucci; Béatrice Saposnik; Dino VeneriPatrizia, Noris; Nicole, Schlegel; Catherine, Klersy; Paula G., Heller; Elisa, Civaschi; Nuria Pujol, Moix; Fabrizio, Fabris; Remi, Favier; Paolo, Gresele; Véronique Latger, Cannard; Adam, Cuker; Paquita, Nurden; Andreas, Greinacher; Marco, Cattaneo; Erica De, Candia; Alessandro, Pecci; Marie Françoise Hurtaud, Roux; Ana C., Glembotsky; Eduardo Muñiz, Diaz; Maria Luigia, Randi; Nathalie, Trillot; Loredana, Bury; Thomas, Lecompte; Caterina, Marconi; Savoia, Anna; Carlo L., Balduini; Sophie, Bayart; Anne, Bauters; Schéhérazade Benabdallah, Guedira; Françoise, Boehlen; Jeanne Yvonne, Borg; Bottega, Roberta; James, Bussel; DE ROCCO, Daniela; Emmanuel de, Maistre; Faleschini, Michela; Emanuela, Falcinelli; Silvia, Ferrari; Alina, Ferster; Tiziana, Fierro; Dominique, Fleury; Pierre, Fontana; Chloé, James; Francois, Lanza; Véronique Le Cam, Duchez; Giuseppe, Loffredo; Pamela, Magini; Dominique Martin, Coignard; Fanny, Menard; Sandra, Mercier; Annamaria, Mezzasoma; Pietro, Minuz; Ilaria, Nichele; Lucia D., Notarangelo; Tommaso, Pippucci; Gian Marco, Podda; Catherine, Pouymayou; Agnes, Rigouzzo; Bruno, Royer; Pierre, Sie; Virginie, Siguret; Catherine, Trichet; Alessandra, Tucci; Béatrice, Saposnik; Dino, Vener

    Fast Tuneable InGaAsP DBR Laser Using Quantum-Confined Stark-Effect-Induced Refractive Index Change

    No full text
    We report a monolithically integrated InGaAsP DBR ridge waveguide laser that uses the quantum-confined Stark effect (QCSE) to achieve fast tuning response. The laser incorporates three sections: a forward-biased gain section, a reverse-biased phase section, and a reverse-biased DBR tuning section. The laser behavior is modeled using transmission matrix equations and tuning over similar to 8 nm is predicted. Devices were fabricated using post-growth shallow ion implantation to reduce the loss in the phase and DBR sections by quantum well intermixing. The lasing wavelength was measured while varying the reverse bias of the phase and DBR sections in the range 0 V to < - 2.5 V. Timing was noncontinuous over a similar to 7-nm-wavelength range, with a side-mode suppression ratio of similar to 20 dB. Coupled cavity effects due to the fabrication method used introduced discontinuities in tuning. The frequency modulation (FM) response was measured to be uniform within 2 dB over the frequency range 10 MHz to 10 GHz, indicating that tuning times of 100 ps are possible.</p
    corecore