56 research outputs found

    A Brief History of OLEDs—Emitter Development and Industry Milestones

    Get PDF
    Organic light‐emitting diodes (OLEDs) have come a long way ever since their first introduction in 1987 at Eastman Kodak. Today, OLEDs are especially valued in the display and lighting industry for their promising features. As one of the research fields that equally inspires and drives development in academia and industry, OLED device technology has continuously evolved over more than 30 years. OLED devices have come forward based on three generations of emitter materials relying on fluorescence (first generation), phosphorescence (second generation), and thermally activated delayed fluorescence (third generation). Furthermore, research in academia and industry toward the fourth generation of OLEDs is in progress. Excerpts from the history of green, orange‐red, and blue OLED emitter development on the side of academia and milestones achieved by key players in the industry are included in this report

    Selective TEMPO-oxidation of alcohols to aldehydes in alternative organic solvents

    Get PDF
    Hinzmann A, Stricker M, Busch J, Glinski S, Oike K, Gröger H. Selective TEMPO-oxidation of alcohols to aldehydes in alternative organic solvents. European Journal of Organic Chemistry. 2020;(16):2399-2408.The TEMPO‐catalyzed oxidation of alcohols to aldehydes has emerged to one of the most widely applied methodologies for such transformations. Advantages are the utilization of sodium hypochlorite, a component of household bleach, as an oxidation agent and the use of water as a co‐solvent. However, a major drawback of this method is the often occurring strict limitation to use dichloromethane as an organic solvent in a biphasic reaction medium with water. Previous studies show that dichloromethane cannot easily be substituted because a decrease of selectivity or inhibition of the reaction is observed by using alternative organic solvents. Thus, up to now, only a few examples are known in which after a tedious optimization of the reaction dichloromethane could be replaced. In order to overcome the current limitations, we were interested in finding a TEMPO‐oxidation method in alternative organic solvents, which is applicable for various alcohol oxidations. As a result, we found a method for N‐oxyl radical‐catalyzed oxidation using sodium hypochlorite as an oxidation agent in nitriles as an organic solvent component instead of dichloromethane. Besides the oxidation of aromatic primary alcohols also aliphatic primary alcohols, secondary alcohols as well as dialcohols were successfully converted when using this method, showing high selectivity towards the carbonyl compound and low amounts of the acid side‐product

    Minor head trauma in infants - how accurate is cranial ultrasound performed by trained radiologists?

    Get PDF
    Correct management of infants after minor head trauma is crucial to minimize the risk to miss clinically important traumatic brain injury (ciTBI). Current practices typically involve CT or in-hospital surveillance. Cranial ultrasound (CUS) provides a radiation-free and fast alternative. This study examines the accuracy of radiologist-performed CUS to detect skull fracture (SF) and/or intracranial hemorrhage (ICH). An inconspicuous CUS followed by an uneventful clinical course would allow exclusion of ciTBI with a great certainty. This monocentric, retrospective, observational study analyzed CUS in infants (< 12 months) after minor head trauma at Bern University Children's Hospital, between 7/2013 and 8/2020. The primary outcome was the sensitivity and specificity of CUS in detecting SF and/or ICH by comparison to the clinical course and to additional neuroimaging. Out of a total of 325 patients, 73% (n = 241) had a normal CUS, 17% (n = 54) were found with SF, and ICH was diagnosed in 2.2% patients (n = 7). Two patients needed neurosurgery and three patients deteriorated clinically during surveillance. Additional imaging was performed in 35 patients. The sensitivity of CUS was 93% ([0.83, 0.97] 95% CI) and the specificity 98% ([0.95, 0.99] 95% CI). All false-negative cases originated in missed SF without clinical deterioration; no ICH was missed.  Conclusion: This study shows high accuracy of CUS in exclusion of SF and ICH, which can cause ciTBI. Therefore, CUS offers a reliable method of neuroimaging in infants after minor head trauma and gives reassurance to reduce the duration of in-hospital surveillance. What is Known: ‱ Minor head trauma can cause clinically important traumatic brain injury in infants, and the management of these cases is a challenge for the treating physician. ‱ Cranial ultrasound (CUS) is regularly used in neonatology, but its accuracy after head trauma in infants is controversial. What is New: ‱ CUS performed by a trained radiologist can exclude findings related to clinically important traumatic brain injury (ciTBI) with high sensitivity and specificity. It therefore offers reassurance in the management of infants after minor head trauma

    Various Structural Design Modifications : para-Substituted Diphenylphosphinopyridine Bridged Cu(I) Complexes in Organic Light-Emitting Diodes

    Get PDF
    The well-known system of dinuclear Cu(I) complexes bridged by 2-(diphenylphosphino)pyridine (PyrPhos) derivatives Cu2X2L3 and Cu2X2LP2 (L = bridging ligand, P = ancillary ligand) goes along with endless variation options for tunability. In this work, the influence of substituents and modifications on the phosphine moiety of the NP-bridging ligand was investigated. In previous studies, the location of the lowest unoccupied molecular orbital (LUMO) of the copper complexes of the PyrPhos family was found to be located on the NP-bridging ligand and enabled color tuning in the whole visible spectrum. A multitude of dinuclear Cu(I) complexes based on the triple methylated 2- (bis (4-methylphenyl)phosphino)-4-methylpyridine (Cu-1b-H, Cu-1b-MeO, and Cu-1b-F) up to complexes bearing 2-(bis(4-fluorophenyl)phosphino)pyridine (Cu-6a-H) with electron-withdrawing fluorine atoms over many other variations on the NP-bridging ligands were synthesized. Almost all copper complexes were confirmed via single crystal X-ray diffraction analysis. Besides theoretical TDDFT-studies of the electronic properties and photophysical measurements, the majority of the phosphinomodified Cu(I) complexes was tested in solution-processed organic light-emitting diodes (OLEDs) with different heterostructure variations. The best results of the OLED devices were obtained with copper emitter Cu-lb-H in a stack architecture of ITO/PEDOT-PSS (50 nm)/poly-TPD (15 nm)/20 wt % Cu(I) emitter:CBP:TcTA(7:3) (45 nm)/TPBi (30 nm)/LiF(1 nm)/Al (>100 nm) with a high brightness of 5900 Cd/m(2) and a good current efficiency of 3.79 Cd/A.Peer reviewe

    Assessment of femoral retroversion on preoperative hip magnetic resonance imaging in patients with slipped capital femoral epiphysis: Theoretical implications for hip impingement risk estimation.

    Get PDF
    PURPOSE Slipped capital femoral epiphysis is a common pediatric hip disease and was associated with femoral retroversion, but femoral version was rarely measured. Therefore, mean femoral version, mean femoral neck version, and prevalence of femoral retroversion were analyzed for slipped capital femoral epiphysis patients. METHODS A retrospective observational study evaluating preoperative hip magnetic resonance imaging of 27 patients (49 hips) was performed. Twenty-seven untreated slipped capital femoral epiphysis patients (28 slipped capital femoral epiphysis hips and 21 contralateral hips, age 10-16 years) were evaluated (79% stable slipped capital femoral epiphysis, 22 patients; 43% severe slipped capital femoral epiphysis, 12 patients). Femoral version was measured using Murphy method on magnetic resonance imaging (January 2014-December 2021, rapid bilateral 3-dimensional T1 water-only Dixon-based images of pelvis and knee). All slipped capital femoral epiphysis patients underwent surgery after magnetic resonance imaging. RESULTS Mean femoral version of slipped capital femoral epiphysis patients (-1° ± 15°) was significantly (p < 0.001) lower compared to contralateral side (15° ± 14°). Femoral version of slipped capital femoral epiphysis patients had significantly (p < 0.001) wider range from -42° to 35° (range 77°) compared to contralateral side (-5° to 44°, range 49°). Mean femoral neck version of slipped capital femoral epiphysis patients (6° ± 15°) was lower compared to contralateral side (11° ± 12°). Fifteen slipped capital femoral epiphysis patients (54%) had absolute femoral retroversion (femoral version < 0°). Six of the 12 hips (50%) with severe slips and 4 of the 8 hips (50%) with mild slips had absolute femoral retroversion (femoral version < 0°). Ten slipped capital femoral epiphysis patients (40%) had absolute femoral neck retroversion (femoral neck version < 0°). CONCLUSION Although slipped capital femoral epiphysis patients showed asymmetrically lower femoral version compared to contralateral side, there was a wide range of femoral version, underlining the importance of patient-specific femoral version analysis on preoperative magnetic resonance imaging. Absolute femoral retroversion was prevalent in half of slipped capital femoral epiphysis patients, in half of severe slipped capital femoral epiphysis patients, and in half of mild slipped capital femoral epiphysis patients. This has implications for anterior hip impingement and for surgical treatment with in situ pinning or femoral osteotomy (e.g. proximal femoral derotation osteotomy) or other hip preservation surgery

    Investigation of Luminescent Triplet States in Tetranuclear Cu-I Complexes : Thermochromism and Structural Characterization

    Get PDF
    To develop new and flexible Cu-I containing luminescent substances, we extend our previous investigations on two metal-centered species to four metal-centered complexes. These complexes could be a basis for designing new organic light-emitting diode (OLED) relevant species. Both the synthesis and in-depth spectroscopic analysis, combined with high-level theoretical calculations are presented on a series of tetranuclear Cu-I complexes with a halide containing Cu4X4 core (X=iodide, bromide or chloride) and two 2-(diphenylphosphino)pyridine bridging ligands with a methyl group in para (4-Me) or ortho (6-Me) position of the pyridine ring. The structure of the electronic ground state is characterized by X-ray diffraction, NMR, and IR spectroscopy with the support of theoretical calculations. In contrast to the para system, the complexes with ortho-substituted bridging ligands show a remarkable and reversible temperature-dependent dual phosphorescence. Here, we combine for the first time the luminescence thermochromism with time-resolved FTIR spectroscopy. Thus, we receive experimental data on the structures of the two triplet states involved in the luminescence thermochromism. The transient IR spectra of the underlying triplet metal/halide-to-ligand charge transfer (M-3/XLCT) and cluster-centered ((CC)-C-3) states were obtained and interpreted by comparison with calculated vibrational spectra. The systematic and significant dependence of the bridging halides was analyzed.Peer reviewe

    Highly soluble fluorine containing Cu(i) AlkylPyrPhos TADF complexes

    Get PDF
    Luminescent Cu(i) AlkylPyrPhos complexes with a butterfly-shaped Cu2I2 core and halogen containing ancillary ligands, with a special focus on fluorine, have been investigated in this study. These complexes show extremely high solubilities and a remarkable (photo)chemical stability in a series of solvents. A tunable emission resulting from thermally activated delayed fluorescence with high quantum yields was determined by luminescence and lifetime investigations in solvents and solids. Structures of the electronic ground states were analyzed by single crystal X-ray analysis. The structure of the lowest excited triplet state was determined by transient FTIR spectroscopy, in combination with quantum chemical calculations. With the obtained range of compounds we address the key requirement for the production of organic light emitting diodes based on solution processing.Peer reviewe

    Jovanka kommt an! Stadtgestaltung fĂŒr einen inklusiven Campus Lichtwiese. StĂ€dtebaulicher Entwurf im Sommersemester 2017.

    Get PDF
    Der TU Darmstadt Campus Lichtwiese wird sich in den nĂ€chsten Jahrzehnten stark entwickeln. Zur Debatte stehen eines neues MobilitĂ€tskonzept, die Neuordnung der FreiflĂ€chen und Nachverdichtung durch studentisches Wohnen. In Rahmen des Entwurfs sollen in Zusammenarbeit mit Studierenden mit eingeschrĂ€nkter MobilitĂ€t, Seh- oder HöreinschrĂ€nkung, und Newcomern in Darmstadt Konzepte entwickelt werden, die ZugĂ€nglichkeit und AufenthaltsqualitĂ€t des Campus (fĂŒr eine der Gruppen) im Sinne des Universal Design und des Access for All erhöhen
    • 

    corecore