6,564 research outputs found
Resolving the structure of TiBe
There has been considerable controversy regarding the structure of
TiBe, which is variously reported as hexagonal and tetragonal. Lattice
dynamics simulations based on density functional theory show the tetragonal
phase space group to be more stable over all temperatures, while the
hexagonal phase exhibits an imaginary phonon mode, which, if followed, would
lead to the cell adopting the tetragonal structure. We then report the
predicted ground state elastic constants and temperature dependence of the bulk
modulus and thermal expansion for the tetragonal phase.Comment: In press at Acta Crystallographica B. Supplementary material appende
Reassessment of the Illinois Ranges of the Bigeye Chub, Hybopsis amblops, and the Pallid Shiner, Notropis amnis
Author Institution: Department of Zoology, Southern Illinois University at CarbondaleExamination of all extant Illinois specimens deposited in museum collections revealed that the Illinois ranges of the bigeye chub, Hybopsis amblops, and pallid shiner, Notropis amnis, were confounded by previous workers. The bigeye chub is now known to have been restricted historically to tributaries of the upper Wabash and Kaskaskia river systems. Recent efforts (1986-1987) to discover extant populations of the species in Illinois were unsuccessful. Thus, it is either extirpated or exists in very low numbers in the state. The pallid shiner is now or was known to occur in the Mississippi River proper, and the Illinois, Kaskaskia, Big Muddy, Saline, and lower Wabash river systems. The species is consistently taken in the Kankakee River and occasionally in the Mississippi River adjacent to Rock Island County, Illinois. In Illinois, the bigeye chub is recognized as endangered; the pallid shiner is recommended for state recognition as endangered
From solid solution to cluster formation of Fe and Cr in -Zr
To understand the mechanisms by which Fe and Cr additions increase the
corrosion rate of irradiated Zr alloys, a combination of experimental (atom
probe tomography, x-ray diffraction and thermoelectric power measurements) and
modelling (density functional theory) techniques are employed to investigate
the non-equilibrium solubility and clustering of Fe and Cr in binary Zr alloys.
Cr occupies both interstitial and substitutional sites in the {\alpha}-Zr
lattice, Fe favours interstitial sites, and a low-symmetry site that was not
previously modelled is found to be the most favourable for Fe. Lattice
expansion as a function of alloying concentration (in the dilute regime) is
strongly anisotropic for Fe additions, expanding the -axis while contracting
the -axis. Defect clusters are observed at higher solution concentrations,
which induce a smaller amount of lattice strain compared to the dilute defects.
In the presence of a Zr vacancy, all two-atom clusters are more soluble than
individual point defects and as many as four Fe or three Cr atoms could be
accommodated in a single Zr vacancy. The Zr vacancy is critical for the
increased solubility of defect clusters, the implications for irradiation
induced microstructure changes in Zr alloys are discussed.Comment: 15 pages including figure, 9 figures, 2 tables. Submitted for
publication in Acta Mater, Journal of Nuclear Materials (2015
Twelve tips for assessment psychometrics.
It is incumbent on medical schools to show, both to regulatory bodies and to the public at large, that their graduating students are "fit for purpose" as tomorrow's doctors. Since students graduate by virtue of passing assessments, it is vital that schools quality assure their assessment procedures, standards, and outcomes. An important part of this quality assurance process is the appropriate use of psychometric analyses. This begins with development of an empowering, evidence-based culture in which assessment validity can be demonstrated. Preparation prior to an assessment requires the establishment of appropriate rules, test blueprinting and standard setting. When an assessment has been completed, the reporting of test results should consider reliability, assessor, demographic, and long-term analyses across multiple levels, in an integrated way to ensure the information conveyed to all stakeholders is meaningful
MHD flow and heat transfer in a rectangular duct
MHD Strömung und Wärmeübergang in einem Rechteckkanal
Lediglich eine profunde Kenntnis des Wärmeübertragungsverhaltens laminarer und turbulenter magnetohydrodynamischer (MHD) Strömungen erlaubt eine adäquate Auslegung von Wärmeübertragern, zum Beispiel von Flüssigmetallblankets, oder eine Steuerung industrieller Verfahren durch den Einsatz von MHD Effekten.
In diesem Bericht wird die experimentelle und numerische Untersuchung einer MHD-Strömung in einem Rechteckkanal mit elektrisch leitenden Wänden vorgestellt. Ein äußeres konstantes Magnetfeld B steht senkrecht auf der Kanalachse und ist ebenfalls senkrecht zum Wärmestrom , der von einem Strahlungsheizer erzeugt wird. Im Kanal werden sowohl integrale Größen wie der Druckverlust und die Nusselt-Zahl aber auch lokale Größen, zum Beispiel die Temperatur an der Fluid-Wand-Grenzfläche, die Geschwindigkeit und die lokale Temperatur ermittelt. Der untersuchte Parameterbereich umfaßt: Hartmann-Zahlen 0£ M£ 5000, Reynolds-Zahlen 0£ Re£ 1.3.105 und Peclet-Zahlen 0£ Pe£ 2900 .
Der gemessene Druckverlust stimmt mit der analytischen Lösung für eine zweidimensionale MHD-Strömung in nahezu dem gesamten untersuchten Parameterbereich überein. Lediglich für Hartmann-Zahlen M£ 350 und Re³ 7.104 wird ein höherer Druckverlust ermittelt. Beim Überschreiten einer kritischen Reynoldszahl Recrit von Recrit=100.M entspricht der MHD-Druckverlust dem einer turbulenten hydrodynamischen Rohrströmung. Die Temperatur- und Geschwindigkeitsverteilung im Kanal, die mit einer kombinierten Temperatur- und Geschwindigkeitsmeßsonde (TEMPO) ermittelt wurde, stimmt mit den berechneten Werten für eine laminare MHD-Strömung überein. Die Nusselt-Zahl an der Wand ist bei MHD-Strömungen aufgrund der wandnahen Geschwindigkeitsüberhöhungen (den sogenannten Seitenwandjets), die sich an Wänden parallel zum Magnetfeld ausbilden und direkt dem Wärmestrom ausgesetzt ist, um ca. 30% größer als in einer hydrodynamischen Strömung. Bei großen M und sehr großen Re entspricht der Wärmeübergang der turbulenten MHD Strömung dem Wärmeübergang wie er auch in einer laminaren Strömung ermittelt wird. Der Grund dafür ist, daß die thermische Grenzschicht sich noch im Bereich der viskosen laminaren Grenzschicht befindet und somit leistet lediglich die molekulare Wärmeleitung einen Beitrag zur Wärmeübertragung. Bei bestimmten Parameterkonstellationen oder bei hinreichend langen Kanälen wächst die Grenzschicht in den Bereich der turbulenten Seitenwandschichten hinein. Durch den turbulenten Quertransport des Fluids wird der Wärmeübergang gesteigert. Die Wärmeübertragungsverbesserung kann um den Faktor 2 höher sein als bei einer laminaren MHD-Strömung
- …