3,071 research outputs found

    Size Acceptance: A Discursive Analysis of Online Blogs

    Get PDF
    This document is an Accepted Manuscript of an article published by Taylor & Francis Group in Fat Studies on 25 May 2018, available online at: https://doi.org/10.1080/21604851.2018.1473704. Under embargo until 25 May 2019.Dominant discourses of “fatness” and “fat people” have implications for physical and mental health. Although alternative discourses such as “size acceptance” exist, there has been little consideration of the ways in which these alternative arguments (and speakers) may be positioned to be heard. Using a discursive thematic analysis, the authors demonstrate that size acceptance online bloggers have created a community online that enables them to persuasively provide alternative claims to “expertise,” which positions their views as credible and legitimate alternatives to those of more established authority figures—such as health professionals. This has implications not only for the lived experience of fat people, but also for researchers by emphasizing the importance of exploring not just what is said, but how, if we are to understand how different articulated positions are to be persuasive.Peer reviewe

    Interplay of gravitation and linear superposition of different mass eigenstates

    Get PDF
    The interplay of gravitation and the quantum-mechanical principle of linear superposition induces a new set of neutrino oscillation phases. These ensure that the flavor-oscillation clocks, inherent in the phenomenon of neutrino oscillations, redshift precisely as required by Einstein's theory of gravitation. The physical observability of these phases in the context of the solar neutrino anomaly, type-II supernovae, and certain atomic systems is briefly discussed

    Percutaneous ct fluoroscopy-guided core needle biopsy of mediastinal masses: Technical outcome and complications of 155 procedures during a 10-year period

    Get PDF
    Purpose: To evaluate technical outcome, diagnostic yield and safety of computed tomo-graphic fluoroscopy-guided percutaneous core needle biopsies in patients with mediastinal masses. Methods: Overall, 155 CT fluoroscopy-guided mediastinal core needle biopsies, performed from March 2010 to June 2020 were included. Size of lesion, size of needle, access path, number of success, number of biopsies per session, diagnostic yield, patient’s position, effective dose, rate of complications, tumor localization, size of tumor and histopathological diagnosis were considered. Post-interventional CT was performed, and patients observed for any complications. Complications were classified per the Society of Interventional Radiology (SIR). Results: 148 patients (age, 54.7 ± 18.2) underwent 155 CT-fluoroscopy-guided percutaneous biopsies with tumors in the anterior (114; 73.5%), middle (17; 11%) and posterior (24; 15.5%) mediastinum, of which 152 (98%) were technically successful. For placement of the biopsy needle, in 82 (52.9%) procedures a parasternal trajectory was chosen, in 36 (23.3%) a paravertebral access, in 20 (12.9%) through the lateral intercostal space and in 17 (11%) the thoracic anterior midline, respectively. A total of 136 (89.5%) of the biopsies were considered adequate for a specific histopathologic analysis. Total DLP (dose-length product) was 575.7 ± 488.8 mGy*cm. Mean lesion size was 6.0 ± 3.3 cm. Neoplastic pathology was diagnosed in 115 (75.7%) biopsies and 35 (23%) biopsy samples showed no evidence of malignancy. Minor complications were observed in 18 (11.6%) procedures and major pneumothorax requiring drainage insertion in 3 interventions (1.9%). Conclusion: CT fluoroscopy-guided percutaneous core needle biopsy of mediastinal masses is an effective and safe procedure for the initial assessment of patients with mediastinal tumors

    MVCSLAM: Mono-Vision Corner SLAM for Autonomous Micro-Helicopters in GPS Denied Environments

    Get PDF
    We present a real-time vision navigation and ranging method (VINAR) for the purpose of Simultaneous Localization and Mapping (SLAM) using monocular vision. Our navigation strategy assumes a GPS denied unknown environment, whose indoor architecture is represented via corner based feature points obtained through a monocular camera. We experiment on a case study mission of vision based SLAM through a conventional maze of corridors in a large building with an autonomous Micro Aerial Vehicle (MAV). We propose a method for gathering useful landmarks from a monocular camera for SLAM use. We make use of the corners by exploiting the architectural features of the manmade indoors

    Exploiting the pathway structure of metabolism to reveal high-order epistasis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Biological robustness results from redundant pathways that achieve an essential objective, e.g. the production of biomass. As a consequence, the biological roles of many genes can only be revealed through multiple knockouts that identify a <it>set </it>of genes as essential for a given function. The identification of such "epistatic" essential relationships between network components is critical for the understanding and eventual manipulation of robust systems-level phenotypes.</p> <p>Results</p> <p>We introduce and apply a network-based approach for genome-scale metabolic knockout design. We apply this method to uncover over 11,000 minimal knockouts for biomass production in an <it>in silico </it>genome-scale model of <it>E. coli</it>. A large majority of these "essential sets" contain 5 or more reactions, and thus represent complex epistatic relationships between components of the <it>E. coli </it>metabolic network.</p> <p>Conclusion</p> <p>The complex minimal biomass knockouts discovered with our approach illuminate robust essential systems-level roles for reactions in the <it>E. coli </it>metabolic network. Unlike previous approaches, our method yields results regarding high-order epistatic relationships and is applicable at the genome-scale.</p

    Beam Test of Silicon Strip Sensors for the ZEUS Micro Vertex Detector

    Get PDF
    For the HERA upgrade, the ZEUS experiment has designed and installed a high precision Micro Vertex Detector (MVD) using single sided micro-strip sensors with capacitive charge division. The sensors have a readout pitch of 120 microns, with five intermediate strips (20 micron strip pitch). An extensive test program has been carried out at the DESY-II testbeam facility. In this paper we describe the setup developed to test the ZEUS MVD sensors and the results obtained on both irradiated and non-irradiated single sided micro-strip detectors with rectangular and trapezoidal geometries. The performances of the sensors coupled to the readout electronics (HELIX chip, version 2.2) have been studied in detail, achieving a good description by a Monte Carlo simulation. Measurements of the position resolution as a function of the angle of incidence are presented, focusing in particular on the comparison between standard and newly developed reconstruction algorithms.Comment: 41 pages, 21 figures, 2 tables, accepted for publication in NIM

    Flux-sum analysis: a metabolite-centric approach for understanding the metabolic network

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Constraint-based flux analysis of metabolic network model quantifies the reaction flux distribution to characterize the state of cellular metabolism. However, metabolites are key players in the metabolic network and the current reaction-centric approach may not account for the effect of metabolite perturbation on the cellular physiology due to the inherent limitation in model formulation. Thus, it would be practical to incorporate the metabolite states into the model for the analysis of the network.</p> <p>Results</p> <p>Presented herein is a metabolite-centric approach of analyzing the metabolic network by including the turnover rate of metabolite, known as flux-sum, as key descriptive variable within the model formulation. By doing so, the effect of varying metabolite flux-sum on physiological change can be simulated by resorting to mixed integer linear programming. From the results, we could classify various metabolite types based on the flux-sum profile. Using the <it>i</it>AF1260 <it>in silico </it>metabolic model of <it>Escherichia coli</it>, we demonstrated that this novel concept complements the conventional reaction-centric analysis.</p> <p>Conclusions</p> <p>Metabolite flux-sum analysis elucidates the roles of metabolites in the network. In addition, this metabolite perturbation analysis identifies the key metabolites, implicating practical application which is achievable through metabolite flux-sum manipulation in the areas of biotechnology and biomedical research.</p

    Measurements of Flavour Dependent Fragmentation Functions in Z^0 -> qq(bar) Events

    Get PDF
    Fragmentation functions for charged particles in Z -> qq(bar) events have been measured for bottom (b), charm (c) and light (uds) quarks as well as for all flavours together. The results are based on data recorded between 1990 and 1995 using the OPAL detector at LEP. Event samples with different flavour compositions were formed using reconstructed D* mesons and secondary vertices. The \xi_p = ln(1/x_E) distributions and the position of their maxima \xi_max are also presented separately for uds, c and b quark events. The fragmentation function for b quarks is significantly softer than for uds quarks.Comment: 29 pages, LaTeX, 5 eps figures (and colour figs) included, submitted to Eur. Phys. J.

    Bose-Einstein Correlations of Three Charged Pions in Hadronic Z^0 Decays

    Get PDF
    Bose-Einstein Correlations (BEC) of three identical charged pions were studied in 4 x 10^6 hadronic Z^0 decays recorded with the OPAL detector at LEP. The genuine three-pion correlations, corrected for the Coulomb effect, were separated from the known two-pion correlations by a new subtraction procedure. A significant genuine three-pion BEC enhancement near threshold was observed having an emitter source radius of r_3 = 0.580 +/- 0.004 (stat.) +/- 0.029 (syst.) fm and a strength of \lambda_3 = 0.504 +/- 0.010 (stat.) +/- 0.041 (syst.). The Coulomb correction was found to increase the \lambda_3 value by \~9% and to reduce r_3 by ~6%. The measured \lambda_3 corresponds to a value of 0.707 +/- 0.014 (stat.) +/- 0.078 (syst.) when one takes into account the three-pion sample purity. A relation between the two-pion and the three-pion source parameters is discussed.Comment: 19 pages, LaTeX, 5 eps figures included, accepted by Eur. Phys. J.
    corecore