353 research outputs found

    Design of a CZT Gamma-Camera for GRB and Fast Transient Follow-up: a Wide-Field-Monitor for the EDGE Mission

    Full text link
    The success of the SWIFT/BAT and INTEGRAL missions has definitely opened a new window for follow-up and deep study of the transient gamma-ray sky. This now appears as the access key to important progresses in the area of cosmological research and deep understanding of the physics of compact objects. To detect in near real-time explosive events like Gamma-Ray bursts, thermonuclear flashes from Neutron Stars and other types of X-ray outbursts we have developed a concept for a wide-field gamma-ray coded mask instrument working in the range 8-200 keV, having a sensitivity of 0.4 ph cm-2 s-1 in 1s (15-150 keV) and arcmin location accuracy over a sky region as wide as 3sr. This scientific requirement can be achieved by means of two large area, high spatial resolution CZT detection planes made of arrays of relatively large (~1cm2) crystals, which are in turn read out as matrices of smaller pixels. To achieve such a wide Field-Of-View the two units can be placed at the sides of a S/C platform serving a payload with a complex of powerful X-ray instruments, as designed for the EDGE mission. The two units will be equipped with powerful signal read out system and data handling electronics, providing accurate on-board reconstruction of the source positions for fast, autonomous target acquisition by the X-ray telescopes.Comment: 9 pages, 7 figures, SPIE Conference on UV, X-ray, and Gamma-Ray Instrumentation for Astronomy, San Diego 26-30 August 200

    The randomized shortened dental arch study (RaSDA): design and protocol

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Various treatment options for the prosthetic treatment of jaws where all molars are lost are under discussion. Besides the placement of implants, two main treatment types can be distinguished: replacement of the missing molars with removable dental prostheses and non-replacement of the molars, i.e. preservation of the shortened dental arch. Evidence is lacking regarding the long-term outcome and the clinical performance of these approaches. High treatment costs and the long time required for the treatment impede respective clinical trials.</p> <p>Methods/design</p> <p>This 14-center randomized controlled investigator-initiated trial is ongoing. Last patient out will be in 2010. Patients over 35 years of age with all molars missing in one jaw and with at least both canines and one premolar left on each side were eligible. One group received a treatment with removable dental prostheses for molar replacement (treatment A). The other group received a treatment limited to the replacement of all missing anterior and premolar teeth using fixed bridges (treatment B). A pilot trial with 32 patients was carried out. Two hundred and fifteen patients were enrolled in the main trial where 109 patients were randomized for treatment A and 106 for treatment B. The primary outcome measure is further tooth loss during the 5-year follow-up. The secondary outcome measures encompassed clinical, technical and subjective variables. The study is funded by the Deutsche Forschungsgemeinschaft (German Research Foundation, DFG WA 831/2-1, 2-2, 2-3, 2-4, 2-5).</p> <p>Discussion</p> <p>The particular value of this trial is the adaptation of common design components to the very specific features of complex dental prosthetic treatments. The pilot trial proved to be indispensable because it led to a number of adjustments in the study protocol that considerably improved the practicability. The expected results are of high clinical relevance and will show the efficacy of two common treatment approaches in terms of oral health. An array of secondary outcome measures will deliver valuable supplementary information. If the results can be implemented in the clinical practice, the daily dental care should strongly profit thereof.</p> <p>Trial registration</p> <p>The trial is registered at ClinicalTrials.gov under ISRCTN68590603 (pilot trial) and ISRCTN97265367 (main trial).</p

    Compton Large Area Silicon Timing Tracker for Cosmic Vision M3

    Get PDF
    International audienceProposed in response to the ESA call for the third Medium size mission (M3), CAPSiTT is a small mission designed for a 3-year survey of the non-thermal high energy sky from an equatorial LEO orbit. With a large effective area and a very wide field of view, its single instrument, a silicon tracker, provides good imaging, spectroscopic and polarimetric capabilities with a sensitivity 10-100 times better than COMPTEL. Nucleosynthesis and particle acceleration mechanisms in various sites are the main scientific topics addressed by CAPSiTT
    corecore