4,679 research outputs found

    FiberGLAST: a scintillating fiber approach to the GLAST mission

    Get PDF
    FiberGLAST is a scintillating fiber gamma-ray detector designed for the GLAST mission. The system described below provides superior effective area and field of view for modest cost and risk. An overview of the FiberGLAST instrument is presented, as well as a more detailed description of the principle elements of the primary detector volume. The triggering and readout electronics are described, and Monte Carlo Simulations of the instrument performance are presented

    Interplay between ferromagnetism, surface states, and quantum corrections in a magnetically doped topological insulator

    Full text link
    The breaking of time-reversal symmetry by ferromagnetism is predicted to yield profound changes to the electronic surface states of a topological insulator. Here, we report on a concerted set of structural, magnetic, electrical and spectroscopic measurements of \MBS thin films wherein photoemission and x-ray magnetic circular dichroism studies have recently shown surface ferromagnetism in the temperature range 15 K ≤T≤100\leq T \leq 100 K, accompanied by a suppressed density of surface states at the Dirac point. Secondary ion mass spectroscopy and scanning tunneling microscopy reveal an inhomogeneous distribution of Mn atoms, with a tendency to segregate towards the sample surface. Magnetometry and anisotropic magnetoresistance measurements are insensitive to the high temperature ferromagnetism seen in surface studies, revealing instead a low temperature ferromagnetic phase at T≲5T \lesssim 5 K. The absence of both a magneto-optical Kerr effect and anomalous Hall effect suggests that this low temperature ferromagnetism is unlikely to be a homogeneous bulk phase but likely originates in nanoscale near-surface regions of the bulk where magnetic atoms segregate during sample growth. Although the samples are not ideal, with both bulk and surface contributions to electron transport, we measure a magnetoconductance whose behavior is qualitatively consistent with predictions that the opening of a gap in the Dirac spectrum drives quantum corrections to the conductance in topological insulators from the symplectic to the orthogonal class.Comment: To appear in Phys. Rev.

    The Use of a Visual Motor Test to Identify Lingering Deficits in Concussed Collegiate Athletes

    Get PDF
    Background: Emerging evidence suggests neurophysiological deficits, such as visual motor coordination (VMC), may persist beyond clinical concussion recovery. Instrumented measurement of upper-limb VMC is critical for neurological evaluation post-concussion and may identify persistent deficits further elucidating persistent neurophysiological impairments not detected by the current clinical assessment battery. Aim: The aim of the study was to determine if a VMC test identifies persistent deficits in concussed collegiate student-athletes who have returned to baseline on clinical concussion assessments. Methods: Thirteen recently concussed intercollegiate student-athletes (male: 7, 18.9±0.7 years, 175.5±12.4 cm, 75.5±23.2 kg), and 13 matched control student-athletes (male: 7, 19.3±1.1 years, 173.5±11.9 cm, 75.8±19.9 kg) completed two testing sessions (T1: \u3c48 h after clinical recovery; T2: 30 days post-concussion) on a visual motor exam. The outcome measures were A* Average score (average number of lights hit on A* exam), simple visual reaction time (SVRT)-RT, and movement time (SVRT-MT) on the Dynavision D2. The dependent variables were compared with a 2 (group) × 2 (time) repeated measures ANOVAs. Results: There was no group interaction in A* average score (F(1,24)=0.036, P=0.849), SVRT-RT (F(1,22)=0.319, P=0.575), and SVRT-MT (F(1,22)=1.179, P=0.188). There was a main effect for time on A* average score (T1: 76.3±10.4 hits; T2: 82.7±11.2 hits; F(1,24)=38.1, P≤0.001) and SVRT-RT (T1: 0.31±0.04; T2: 0.29±0.04 s; F(1,22)=4.9, P=0.039). There was no main effect for SVRT-MT. There were no group differences at either time point. Conclusions: Among recently concussed collegiate student-athletes, no persistent deficits were identified in VMC beyond clinical recovery when assessed by Dynavision D2. This VMC exam may not provide a useful means of tracking recovery following concussion likely due to a substantial practice effect. Relevance for patients: While post-concussion neurophysiological deficits persist beyond clinical recovery, the laboratory based VMC assessment herein did not identify deficits at critical post-concussion time points. Therefore, other clinically translatable VMC assessments should be further investigated

    Beam test results for the FiberGLAST instrument

    Get PDF
    The FiberGLAST scintillating fiber telescope is a large-area instrument concept for NASA\u27s GLAST program. The detector is designed for high-energy gamma-ray astronomy, and uses plastic scintillating fibers to combine a photon pair tracking telescope and a calorimeter into a single instrument. A small prototype detector has been tested with high energy photons at the Thomas Jefferson National Accelerator Facility. We report on the result of this beam test, including scintillating fiber performance, photon track reconstruction, angular resolution, and detector efficiency

    Implementation of Image Reconstruction for GE SIGNA PET/MR PET Data in the STIR Library

    Get PDF
    Software for Tomographic Image Reconstruction (STIR: http://stir.sf.net) is an open source C++ library available for reconstruction of emission tomography data. This work aims at the incorporation of the GE SIGNA PET/MR scanner in STIR and enables PET image reconstruction with data corrections. The data extracted from the scanner after an acquisition includes a list of raw data files (emission, normalisation, geometric and well counter calibration (wcc) factors), magnetic resonance attenuation correction (MRAC) images and the scanner-based reconstructions. The listmode (LM) file stores a list of 'prompt' events and the singles per crystal per second. MRAC images from the scanner are used for attenuation correction. The modifications to STIR that allow accurate histogramming of this LM data in the same sinogram organisation as the scanner are also described. This allows reconstruction of acquisition data with all data corrections using STIR, and independent of any software supplied by the manufacturer. The implementations were validated by comparing the histogrammed data, data corrections and final reconstruction using the ordered subset expectation maximisation (OSEM) algorithm with the equivalents from the GE-toolbox, supplied by the manufacturer for the scanner. There is no difference in the histogrammed counts whereas an overall relative difference of 6.7 × 10 -8 % and from 0.01% to 0.86% is seen in the normalisation and randoms correction sinograms respectively. The STIR reconstructed images have similar resolution and quantification but have some residual differences due to wcc factors, decay and deadtime corrections, as well as the offset between PET and MR gantries that will be addressed in future work. This work will enable the use of all current and future STIR algorithms, including penalized image reconstruction, motion correction and direct parametric image estimation, on data from GE SIGNA PET/MR scanners

    Estimation of GRB detection by FiberGLAST

    Get PDF
    FiberGLAST is one of several instrument concepts being developed for possible inclusion as the primary Gamma-ray Large Area Space Telescope (GLAST) instrument. The predicted FiberGLAST effective area is more than 12,000 cm2 for energies between 30 MeV and 300 GeV, with a field of view that is essentially flat from 0°–80°. The detector will achieve a sensitivity more than 10 times that of EGRET. We present results of simulations that illustrate the sensitivity of FiberGLAST for the detection of gamma-ray bursts

    Assessment of Scotopic Function in Rod–Cone Inherited Retinal Degeneration With the Scotopic Macular Integrity Assessment

    Get PDF
    Purpose: The scotopic macular integrity assessment (S-MAIA) can perform scotopic assessment to detect localized changes to scotopic rod and cone function. This study is an exploratory investigation of the feasibility of using the S-MAIA in a rod–cone dystrophy population to identify the pattern of loss in scotopic photoreceptor function. Methods: Twenty patients diagnosed with a rod–cone dystrophy underwent visual acuity testing, full-field stimulus threshold assessment, and multiple S-MAIA tests after dark adaptation periods of 20 minutes and 45 minutes performed separately. Only right eyes were tested. Three tests were performed following a learning test. A Bland–Altman analysis was used to assess repeatability and agreement between tests after the two time periods. Spatial interpolation maps were created from the group plots to display the pattern of rod and cone loss. Results: Learning effects took place between testing sessions 1 and 2 but not 2 and 3. Limits of agreement were larger in the patient eyes than control eyes, but within previously reported values. Using longer adaptation time of 45 minutes did not offer a significant advantage over 20 minutes. Patterns for the cyan and red sensitivities were different, indicating different patterns of loss for rods and cones. Conclusions: A dark adaptation time of 20 minutes before testing is sufficient for thresholding. The S-MAIA is suitable for use in patients with a logarithm of the minimum angle of resolution vision of at least 0.7 and provides a viable outcome measure for patients with rod–cone dystrophies and preserved central vision. The spatial information about scotopic function from the S-MAIA provides information about disease processes and progression. Translational Relevance: There is a need for scotopic measures for use in clinical trials. Scotopic microperimetry works well in patients with early disease, allowing the extension of recruitment criteria for novel therapies of rod–cone dystrophies

    Development and testing of a fiber/multianode photomultiplier system for use on FiberGLAST

    Get PDF
    A scintillating fiber detector is currently being studied for the NASA Gamma-Ray Large Area Space Telescope (GLAST) mission. This detector utilizes modules composed of a thin converter sheet followed by an x, y plane of scintillating fibers to examine the shower of particles created by high energy gamma-rays interacting in the converter material. The detector is composed of a tracker with 90 such modular planes and a calorimeter with 36 planes. The two major component of this detector are the scintillating fibers and their associated photodetectors. Here we present current status of development and test result of both of these. The Hamamatsu R5900-00-M64 multianode photomultiplier tube (MAPMT) is the baseline readout device. A characterization of this device has been performed including noise, cross- talk, gain variation, vibration, and thermal/vacuum test. A prototype fiber/MAPMT system has been tested at the Center for Advanced Microstructures and Devices at Louisiana State University with a photon beam and preliminary results are presented

    A Double-Blind, Randomized, Placebo-Controlled Trial of Ursodeoxycholic Acid (UDCA) in Parkinson's Disease

    Get PDF
    BACKGROUND: Rescue of mitochondrial function is a promising neuroprotective strategy for Parkinson's disease (PD). Ursodeoxycholic acid (UDCA) has shown considerable promise as a mitochondrial rescue agent across a range of preclinical in vitro and in vivo models of PD. OBJECTIVES: To investigate the safety and tolerability of high-dose UDCA in PD and determine midbrain target engagement. METHODS: The UP (UDCA in PD) study was a phase II, randomized, double-blind, placebo-controlled trial of UDCA (30 mg/kg daily, 2:1 randomization UDCA vs. placebo) in 30 participants with PD for 48 weeks. The primary outcome was safety and tolerability. Secondary outcomes included 31-phosphorus magnetic resonance spectroscopy (31 P-MRS) to explore target engagement of UDCA in PD midbrain and assessment of motor progression, applying both the Movement Disorder Society Unified Parkinson's Disease Rating Scale Part III (MDS-UPDRS-III) and objective, motion sensor-based quantification of gait impairment. RESULTS: UDCA was safe and well tolerated, and only mild transient gastrointestinal adverse events were more frequent in the UDCA treatment group. Midbrain 31 P-MRS demonstrated an increase in both Gibbs free energy and inorganic phosphate levels in the UDCA treatment group compared to placebo, reflecting improved ATP hydrolysis. Sensor-based gait analysis indicated a possible improvement of cadence (steps per minute) and other gait parameters in the UDCA group compared to placebo. In contrast, subjective assessment applying the MDS-UPDRS-III failed to detect a difference between treatment groups. CONCLUSIONS: High-dose UDCA is safe and well tolerated in early PD. Larger trials are needed to further evaluate the disease-modifying effect of UDCA in PD. © 2023 The Authors. Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society

    LHC Searches for Non-Chiral Weakly Charged Multiplets

    Get PDF
    Because the TeV-scale to be probed at the Large Hadron Collider should shed light on the naturalness, hierarchy, and dark matter problems, most searches to date have focused on new physics signatures motivated by possible solutions to these puzzles. In this paper, we consider some candidates for new states that although not well-motivated from this standpoint are obvious possibilities that current search strategies would miss. In particular we consider vector representations of fermions in multiplets of SU(2)LSU(2)_L with a lightest neutral state. Standard search strategies would fail to find such particles because of the expected small one-loop-level splitting between charged and neutral states.Comment: 16 pages, 9 figure
    • …
    corecore