137 research outputs found

    New Chemicals May Help Trefoil Seed Harvest

    Get PDF
    Though birdsfoot trefoil sets between 200 and 300 pounds of seed per acre in Iowa, harvested yields are commonly only 40 to 60 pounds. Use of chemical desicants followed by direct combining offers a possible solution

    Quantitative rainbow schlieren deflectometry

    Get PDF
    In the rainbow schlieren apparatus, a continuously graded rainbow filter is placed in the back focal plane of the decollimating lens. Refractive-index gradients in the test section thus appear as gradations in hue rather than irradiance. A simple system is described wherein a conventional color CCD array and video digitizer are used to quantify accurately the color attributes of the resulting image, and hence the associated ray deflections. The present system provides a sensitivity comparable with that of conventional interferometry, while being simpler to implement and less sensitive to mechanical misalignment

    Simulated Tractor Chassis Suspension System

    Get PDF
    The development of a chassis suspension system for an agricultural tractor has been described to improve the operator ride comfort. Computer simulation tech-niques were used to formulate the tractor models and to compute the natural frequencies and frequency response of the models, as well as the RMS acceleration response, to evaluate the effect of the suspension system and cab position on operator ride comfort

    Liver Directed Drugs for Transthyretin-Mediated Amyloidosis

    Get PDF
    AIM: Transthyretin-mediated amyloidosis (ATTR) is a rare, under-recognized, progressively debilitating, fatal disease caused by the aggregation and extracellular deposition of amyloid transthyretin (TTR) fibrils in multiple organs and tissues throughout the body. TTR is predominantly synthesized by the liver, and normally circulates as a homotetramer, while misfolded monomers aggregate to form amyloid fibrils. One strategy to treat ATTR amyloidosis is to reduce the amount of TTR produced by the liver using drugs that directly target the TTR mRNA or gene. METHODS: This narrative review focuses on how TTR gene silencing tools act to reduce TTR production, describing strategies for improved targeted delivery of these agents to hepatocytes where TTR is preferentially expressed. RESULTS: Antisense oligonucleotides (ASOs) and small interfering RNAs (siRNAs), termed RNA silencers, cause selective degradation of TTR mRNA, while a TTR gene editing tool reduces TTR expression by introducing nonsense mutations into the TTR gene. Two strategies to facilitate tissue-specific delivery of these nucleic acid-based drugs employ endogenous receptors expressed by hepatocytes. Lipid nanoparticles (LNPs) that recruit apolipoprotein E support low density lipoprotein receptor-mediated uptake of unconjugated siRNA and is now used for CRISPR gene editing tools. Additionally, conjugating N-acetylgalactosamine (GalNAc) moieties to ASOs or siRNAs facilitates receptor-mediated uptake by the asialoglycoprotein receptor. CONCLUSION: ATTR is a progressive disease with various clinical manifestations due to TTR aggregation, deposition, and amyloid formation. Receptor-targeted ligands (e.g., GalNAc) and nanoparticle encapsulation (e.g., LNPs) are technologies to deliver ASOs, siRNAs, and gene editing tools to hepatocytes, the primary location of TTR synthesis

    The COMPASS RICH-1 MPGD based photon detector performance

    Get PDF
    In 2016 we have upgraded the COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four new photon detectors, covering a total active area of 1.5 m2, have been installed in order to cope with the challenging efficiency and stability requirements of the COMPASS physics programme. The new detector architecture consists in a hybrid MPGD combination: two layers of THGEMs, the first of which also acts as a reflective photocathode thanks to CsI coating, are coupled to a bulk Micromegas on a pad-segmented anode. These detectors are the first application in an experiment of MPGD-based single photon detectors. Presently, we are further developing the MPGD-based PDs to make them adequate for a setup at the future EIC collider. All aspects of the COMPASS RICH-1 Photon Detectors upgrade are presented: R&D, engineering, mass production, QA and performance; the on-going development for collider application is also presented

    Flexibility and Fairness in Liberal Market Economies: The Comparative Impact of the Legal Environment and High Performance Work Systems

    Get PDF
    This paper compares management flexibility in employment decision-making in the United States and Canada through a cross-national survey of organizations in representative jurisdictions in each country, Pennsylvania and Ontario respectively, that investigates the impact of differences in their legal environments. The results indicate that, compared to their Ontario counterparts, organizations in Pennsylvania have a higher degree of flexibility in employment outcomes, such as higher dismissal and discipline rates, yet do not experience any greater flexibility or simplicity in management hiring and firing decisions. One explanation for this result may lie in the finding that organizations in Pennsylvania experience greater legal pressures on decision making, reflecting the generally more intense conflict in the employment law system in the United States. By contrast, high performance work systems, which some have looked to as a possible management-driven mechanism for enhancing fairness in employment, had more modest effects

    Minimally invasive computer-navigated total hip arthroplasty, following the concept of femur first and combined anteversion: design of a blinded randomized controlled trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Impingement can be a serious complication after total hip arthroplasty (THA), and is one of the major causes of postoperative pain, dislocation, aseptic loosening, and implant breakage. Minimally invasive THA and computer-navigated surgery were introduced several years ago. We have developed a novel, computer-assisted operation method for THA following the concept of "femur first"/"combined anteversion", which incorporates various aspects of performing a functional optimization of the cup position, and comprehensively addresses range of motion (ROM) as well as cup containment and alignment parameters. Hence, the purpose of this study is to assess whether the artificial joint's ROM can be improved by this computer-assisted operation method. Second, the clinical and radiological outcome will be evaluated.</p> <p>Methods/Design</p> <p>A registered patient- and observer-blinded randomized controlled trial will be conducted. Patients between the ages of 50 and 75 admitted for primary unilateral THA will be included. Patients will be randomly allocated to either receive minimally invasive computer-navigated "femur first" THA or the conventional minimally invasive THA procedure. Self-reported functional status and health-related quality of life (questionnaires) will be assessed both preoperatively and postoperatively. Perioperative complications will be registered. Radiographic evaluation will take place up to 6 weeks postoperatively with a computed tomography (CT) scan. Component position will be evaluated by an independent external institute on a 3D reconstruction of the femur/pelvis using image-processing software. Postoperative ROM will be calculated by an algorithm which automatically determines bony and prosthetic impingements.</p> <p>Discussion</p> <p>In the past, computer navigation has improved the accuracy of component positioning. So far, there are only few objective data quantifying the risks and benefits of computer navigated THA. Therefore, this study has been designed to compare minimally invasive computer-navigated "femur first" THA with a conventional technique for minimally invasive THA. The results of this trial will be presented as soon as they become available.</p> <p>Trial registration number</p> <p>DRKS00000739</p

    Microcirculatory alterations: potential mechanisms and implications for therapy

    Get PDF
    Multiple experimental and human trials have shown that microcirculatory alterations are frequent in sepsis. In this review, we discuss the characteristics of these alterations, the various mechanisms potentially involved, and the implications for therapy. Sepsis-induced microvascular alterations are characterized by a decrease in capillary density with an increased number of stopped-flow and intermittent-flow capillaries, in close vicinity to well-perfused capillaries. Accordingly, the surface available for exchange is decreased but also is highly heterogeneous. Multiple mechanisms may contribute to these alterations, including endothelial dysfunction, impaired inter-cell communication, altered glycocalyx, adhesion and rolling of white blood cells and platelets, and altered red blood cell deformability. Given the heterogeneous nature of these alterations and the mechanisms potentially involved, classical hemodynamic interventions, such as fluids, red blood cell transfusions, vasopressors, and inotropic agents, have only a limited impact, and the microcirculatory changes often persist after resuscitation. Nevertheless, fluids seem to improve the microcirculation in the early phase of sepsis and dobutamine also can improve the microcirculation, although the magnitude of this effect varies considerably among patients. Finally, maintaining a sufficient perfusion pressure seems to positively influence the microcirculation; however, which mean arterial pressure levels should be targeted remains controversial. Some trials using vasodilating agents, especially nitroglycerin, showed promising initial results but they were challenged in other trials, so it is difficult to recommend the use of these agents in current practice. Other agents can markedly improve the microcirculation, including activated protein C and antithrombin, vitamin C, or steroids. In conclusion, microcirculatory alterations may play an important role in the development of sepsis-related organ dysfunction. At this stage, therapies to target microcirculation specifically are still being investigated
    corecore