4,081 research outputs found

    Oscillatory instabilities during the electrocatalytic oxidation of methanol on platinum

    Get PDF
    It is described in this paper the experimental observation of oscillatory dynamics during the electrocatalytic oxidation of methanol on platinum. Besides the previously reported potential oscillations, current oscillations obtained under potentiostatic control are also presented. The existence region of current oscillations is mapped in an applied voltage x resistance bifurcation diagram. Conjointly with electrochemical investigations, in situ FTIR spectroscopy was also employed in the present studies. Although we were not able to follow eventual intermediate coverage changes during the oscillations, those experiments revealled that the mean coverage of adsorbed carbon monoxide remains appreciably high along the oscillations. Results are discussed and compared with the oscillations observed in the electrooxidation of formic acid, a system whose behavior is more understood and widely supported by in situ spectroscopic data.Descreve-se neste artigo a observação experimental de dinâmica oscilatória durante a oxidação eletrocatalítica de metanol sobre platina. Além das, previamente relatadas, oscilações de potencial, oscilações de corrente obtidas sob controle potenciostático também são apresentadas. A região de existência de oscilações de corrente é mapeada no plano de bifurcação voltagem aplicada x resistência. Conjuntamente com investigações eletroquímicas, espectroscopia FTIR in situ também foi aplicada nestes estudos. Apesar de não ter sido possível acompanhar eventuais variações de intermediários reacionais durante as oscilações, tais experimentos revelaram que a cobertura média de monóxido de carbono permanece consideravelmente alta durante as oscilações. Os resultados são discutidos e comparados com as oscilações observadas na eletrooxidação de ácido fórmico, um sistema cujo comportamento é mais entendido e amplamente fundamentado por dados espectroscópicos obtidos in situ.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)CNP

    Reference concentrations for trace elements in urine for the Brazilian population based on q-ICP-MS with a simple dilute-and-shoot procedure

    Get PDF
    Biomonitoring of trace elements is of critical importance in human health assessment. However, trace element concentrations in biological fluids are affected by environmental and physiological parameters, and therefore considerable variations can occur between specific population subgroups. Brazil is a large country with large environmental diversity and with a limited knowledge of the reference values (baseline data) for trace elements in biological fluids. Atomic absorption spectrometry (AAS) and inductively coupled plasma emission spectrometry (ICP-OES) are still the dominant analytical techniques used for biomonitoring trace element analysis in clinical specimens. However, the use of ICP-MS is becoming more usual in clinical laboratory analysis. Then, we evaluated here a simple dilute-and-shoot method for sequential determination of Al, Ba, Be, Cd, Co, Cu, Cs, Mn, Ni, Pb, Pt, Sb, Se, Sn, Tl and U in urine by quadrupole inductively coupled plasma mass spectrometry (q-ICP-MS). Urine samples (500 µL) were accurately pipetted into conical tubes (15 mL) and diluted to 10 mL with a solution containing 0.5 % (v/v) HNO3 + 0.005% (v/v) Triton X-100. Diluted urine samples also contain rhodium, iridium and yttrium added as internal standards. After that, samples were directly analyzed by ICP-MS against matrix-matching calibration. Method detection limit (3s, n = 20) were in the ng L-1 range for all analytes. The method was applied to the analysis of 412 ordinary urine samples from Brazilian healthy and non-exposed subjects to establish reference values. Data validation was provided by the analysis of the standard reference material (SRM) 2670a toxic elements in urine (freeze-dried) (high and low levels) from the National Institute of Standards and Technology (NIST) and reference urine samples from the trace elements intercomparison program operated by the Institut National de Sante' Publique du Quebec, Canada.O biomonitoramento de elementos químicos é de extrema importância na avaliação da saúde humana. Entretanto, as concentrações dos elementos químicos nos fluidos biológicos são afetadas por parâmetros ambientais e fisiológicos e, consequentemente, consideráveis variações podem ocorrer entre subgrupos de populações específicas. O Brasil é um país com ampla diversidade ambiental e existe limitado conhecimento de valores de referência para elementos químicos em fluidos biológicos. A espectrometria de absorção atômica (AAS) e a espectrometria de emissão ótica com plasma acoplado indutivamente (ICP-OES) ainda são as técnicas analíticas mais comumente empregadas no biomonitoramento de elementos químicos em amostras clínicas. Entretanto, o uso da espectrometria de massas com plasma acoplado indutivamente (ICP-MS) está se tornando a cada dia mais comum nos laboratórios clínicos. Neste estudo, foi avaliado um método rápido envolvendo simples diluição da amostra para determinação de Al, Ba, Be, Cd, Co, Cu, Cs, Mn, Ni, Pb, Pt, Sb, Se, Sn, Tl e U em urina por ICP-MS. Amostras de urina (500 μL) foram pipetadas em frascos cônicos de 15 mL e diluídas para 10 mL com uma solução contendo 0,5 % (v/v) HNO3 + 0,005% (v/v) Triton X-100. Ródio, irídio e ítrio foram adicionados como padrões internos. Em seguida, as amostras foram diretamente analisadas por ICP-MS com calibração por ajuste de matriz. Os limites de detecção do método (3s, n = 20) foram da ordem de ng L-1 para todos os analitos em estudo. O método foi aplicado para a análise de 412 amostras de urina de brasileiros saudáveis e não expostos ambientalmente ou ocupacionalmente a metais para o estabelecimento de valores de referência na população brasileira. A validação dos resultados foi acompanhada pela análise de material de referência certificada de urina (SRM) 2670a proveniente do National Institute of Standards and Technology (NIST) e de materiais de referência provenientes do Institut National de Sante' Publique Du Quebec, no Canadá.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq

    Fractal Descriptors in the Fourier Domain Applied to Color Texture Analysis

    Get PDF
    The present work proposes the development of a novel method to provide descriptors for colored texture images. The method consists in two steps. In the first, we apply a linear transform in the color space of the image aiming at highlighting spatial structuring relations among the color of pixels. In a second moment, we apply a multiscale approach to the calculus of fractal dimension based on Fourier transform. From this multiscale operation, we extract the descriptors used to discriminate the texture represented in digital images. The accuracy of the method is verified in the classification of two color texture datasets, by comparing the performance of the proposed technique to other classical and state-of-the-art methods for color texture analysis. The results showed an advantage of almost 3% of the proposed technique over the second best approach.Comment: Chaos, Volume 21, Issue 4, 201

    Evaluation of inductively coupled plasma mass spectrometry for determining Ca, Cu, Fe, Mg, Mn, Se and Zn in bovine semen samples using a simple sample dilution method

    Get PDF
    A simple and fast method for the determination of Ca, Cu, Fe, Mg, Mn, Se and Zn in bovine semen by quadrupole inductively coupled plasma spectrometry (q-ICP-MS) is described. Prior to analysis, samples (200 µL) were diluted 1:50 in a solution containing 0.01% v/v Triton® X-100 and 0.5% v/v nitric acid and directly analyzed by ICP-MS. The limits of detection of the method are 0.3, 0.03, 0.2, 0.04, 0.04, 0.03 and 0.03 µg L-1 for 44Ca, 63Cu, 57Fe, 24Mg, 64Zn, 82Se and 55Mn, respectively. For purposes of comparison and method validation, four ordinary bovine semen samples were directly analyzed by ICP-MS and by flame atomic absorption spectrometry (FAAS) or graphite furnace atomic absorption spectrometry (GF AAS), with no statistical difference between the techniques at the 95% level when applying the t-test. Then, the proposed method was applied in the determinations of Ca, Cu, Fe, Mg, Mn, Se and Zn in collected samples of bovine semen from different breeds, which are used in reproduction programs and artificial insemination

    Enhancing Volumetric Bouligand-Minkowski Fractal Descriptors by using Functional Data Analysis

    Get PDF
    This work proposes and study the concept of Functional Data Analysis transform, applying it to the performance improving of volumetric Bouligand-Minkowski fractal descriptors. The proposed transform consists essentially in changing the descriptors originally defined in the space of the calculus of fractal dimension into the space of coefficients used in the functional data representation of these descriptors. The transformed decriptors are used here in texture classification problems. The enhancement provided by the FDA transform is measured by comparing the transformed to the original descriptors in terms of the correctness rate in the classification of well known datasets

    Global Analyses Of Ceratocystis Cacaofunesta Mitochondria: From Genome To Proteome.

    Get PDF
    The ascomycete fungus Ceratocystis cacaofunesta is the causal agent of wilt disease in cacao, which results in significant economic losses in the affected producing areas. Despite the economic importance of the Ceratocystis complex of species, no genomic data are available for any of its members. Given that mitochondria play important roles in fungal virulence and the susceptibility/resistance of fungi to fungicides, we performed the first functional analysis of this organelle in Ceratocystis using integrated omics approaches. The C. cacaofunesta mitochondrial genome (mtDNA) consists of a single, 103,147-bp circular molecule, making this the second largest mtDNA among the Sordariomycetes. Bioinformatics analysis revealed the presence of 15 conserved genes and 37 intronic open reading frames in C. cacaofunesta mtDNA. Here, we predicted the mitochondrial proteome (mtProt) of C. cacaofunesta, which is comprised of 1,124 polypeptides - 52 proteins that are mitochondrially encoded and 1,072 that are nuclearly encoded. Transcriptome analysis revealed 33 probable novel genes. Comparisons among the Gene Ontology results of the predicted mtProt of C. cacaofunesta, Neurospora crassa and Saccharomyces cerevisiae revealed no significant differences. Moreover, C. cacaofunesta mitochondria were isolated, and the mtProt was subjected to mass spectrometric analysis. The experimental proteome validated 27% of the predicted mtProt. Our results confirmed the existence of 110 hypothetical proteins and 7 novel proteins of which 83 and 1, respectively, had putative mitochondrial localization. The present study provides the first partial genomic analysis of a species of the Ceratocystis genus and the first predicted mitochondrial protein inventory of a phytopathogenic fungus. In addition to the known mitochondrial role in pathogenicity, our results demonstrated that the global function analysis of this organelle is similar in pathogenic and non-pathogenic fungi, suggesting that its relevance in the lifestyle of these organisms should be based on a small number of specific proteins and/or with respect to differential gene regulation. In this regard, particular interest should be directed towards mitochondrial proteins with unknown function and the novel protein that might be specific to this species. Further functional characterization of these proteins could enhance our understanding of the role of mitochondria in phytopathogenicity.149

    Prime Focus Spectrograph - Subaru's future -

    Full text link
    The Prime Focus Spectrograph (PFS) of the Subaru Measurement of Images and Redshifts (SuMIRe) project has been endorsed by Japanese community as one of the main future instruments of the Subaru 8.2-meter telescope at Mauna Kea, Hawaii. This optical/near-infrared multi-fiber spectrograph targets cosmology with galaxy surveys, Galactic archaeology, and studies of galaxy/AGN evolution. Taking advantage of Subaru's wide field of view, which is further extended with the recently completed Wide Field Corrector, PFS will enable us to carry out multi-fiber spectroscopy of 2400 targets within 1.3 degree diameter. A microlens is attached at each fiber entrance for F-ratio transformation into a larger one so that difficulties of spectrograph design are eased. Fibers are accurately placed onto target positions by positioners, each of which consists of two stages of piezo-electric rotary motors, through iterations by using back-illuminated fiber position measurements with a wide-field metrology camera. Fibers then carry light to a set of four identical fast-Schmidt spectrographs with three color arms each: the wavelength ranges from 0.38 {\mu}m to 1.3 {\mu}m will be simultaneously observed with an average resolving power of 3000. Before and during the era of extremely large telescopes, PFS will provide the unique capability of obtaining spectra of 2400 cosmological/astrophysical targets simultaneously with an 8-10 meter class telescope. The PFS collaboration, led by IPMU, consists of USP/LNA in Brazil, Caltech/JPL, Princeton, & JHU in USA, LAM in France, ASIAA in Taiwan, and NAOJ/Subaru.Comment: 13 pages, 11 figures, submitted to "Ground-based and Airborne Instrumentation for Astronomy IV, Ian S. McLean, Suzanne K. Ramsay, Hideki Takami, Editors, Proc. SPIE 8446 (2012)
    corecore