14 research outputs found

    Mesh shrinkage and pain in laparoscopic ventral hernia repair: a randomized clinical trial comparing suture versus tack mesh fixation

    Get PDF
    Background: Mesh fixation during laparoscopic ventral hernia repair can be performed using transfascial sutures or metal tacks. The aim of the present study is to compare mesh shrinkage and pain between two different techniques of mesh fixation in a prospective randomized trial. Methods: A randomized trial was performed. Patients with ventral hernia of maximal diameter 8cm were assigned to mesh fixation using either transfascial nonabsorbable sutures or metal tacks for fixation of a parietene composite mesh. The borders of the mesh were marked using clips, and radiological images in prone position were used for assessment of mesh size and location. The primary endpoint was mesh shrinkage; secondary endpoints included postoperative pain, mesh dislocation, and surgical morbidity. Results: Demographic parameters were similar in both groups. A total of 40 patients were randomized, and 36 patients were available for follow-up. There was one hernia recurrence in each group. Pain was significantly higher following suture fixation after 6weeks, but no difference was found after 6months. Mesh shrinkage after 6months was significantly higher using tacks for mesh fixation. Conclusions: Transfascial sutures are associated with more pain within the first 6 postoperative weeks and less mesh shrinkage after 6months compared with mesh fixation using metal tack

    Indocyanine Green Plasma Disappearance Rate During the Anhepatic Phase of Orthotopic Liver Transplantation

    Get PDF
    Non-invasive pulse spectrophotometry to measure indocyanine green (ICG) elimination correlates well with the conventional invasive ICG clearance test. Nevertheless, the precision of this method remains unclear for any application, including small-for-size liver remnants. We therefore measured ICG plasma disappearance rate (PDR) during the anhepatic phase of orthotopic liver transplantation using pulse spectrophotometry. Measurements were done in 24 patients. The median PDR after exclusion of two outliers and two patients with inconstant signal was 1.55%/min (95% confidence interval [CI] = 0.8-2.2). No correlation with patient age, gender, body mass, blood loss, administration of fresh frozen plasma, norepinephrine dose, postoperative albumin (serum), or difference in pre and post transplant body weight was detected. In conclusion, we found an ICG-PDR different from zero in the anhepatic phase, an overestimation that may arise in particular from a redistribution into the interstitial space. If ICG pulse spectrophotometry is used to measure functional hepatic reserve, the verified average difference from zero (1.55%/min) determined in our study needs to be taken into accoun

    Different Contribution of Splanchnic Organs to Hyperlactatemia in Fecal Peritonitis and Cardiac Tamponade

    Get PDF
    Background. Changes in hepatosplanchnic lactate exchange are likely to contribute to hyperlactatemia in sepsis. We hypothesized that septic and cardiogenic shock have different effects on hepatosplanchnic lactate exchange and its contribution to hyperlactatemia. Materials and Methods. 24 anesthetized pigs were randomized to fecal peritonitis (P), cardiac tamponade (CT), and to controls ( = 8 per group). Oxygen transport and lactate exchange were calculated during 24 hours. Results. While hepatic lactate influx increased in P and in CT, hepatic lactate uptake remained unchanged in P and decreased in CT. Hepatic lactate efflux contributed 20% (P) and 33% (CT), respectively, to whole body venous efflux. Despite maintained hepatic arterial blood flow, hepatic oxygen extraction did not increase in CT. Conclusions. Whole body venous lactate efflux is of similar magnitude in hyperdynamic sepsis and in cardiogenic shock. Although jejunal mucosal pCO 2 gradients are increased, enhanced lactate production from other tissues is more relevant to the increased arterial lactate. Nevertheless, the liver fails to increase hepatic lactate extraction in response to rising hepatic lactate influx, despite maintained hepatic oxygen consumption. In cardiac tamponade, regional, extrasplanchnic lactate production is accompanied by hepatic failure to increase oxygen extraction and net hepatic lactate output, despite maintained hepatic arterial perfusion

    Effect of fluid resuscitation on mortality and organ function in experimental sepsis models

    Get PDF
    Introduction Several recent studies have shown that a positive fluid balance in critical illness is associated with worse outcome. We tested the effects of moderate vs. high-volume resuscitation strategies on mortality, systemic and regional blood flows, mitochondrial respiration, and organ function in two experimental sepsis models. Methods 48 pigs were randomized to continuous endotoxin infusion, fecal peritonitis, and a control group (n = 16 each), and each group further to two different basal rates of volume supply for 24 hours [moderate-volume (10 ml/kg/h, Ringer's lactate, n = 8); high-volume (15 + 5 ml/kg/h, Ringer's lactate and hydroxyethyl starch (HES), n = 8)], both supplemented by additional volume boli, as guided by urinary output, filling pressures, and responses in stroke volume. Systemic and regional hemodynamics were measured and tissue specimens taken for mitochondrial function assessment and histological analysis. Results Mortality in high-volume groups was 87% (peritonitis), 75% (endotoxemia), and 13% (controls). In moderate-volume groups mortality was 50% (peritonitis), 13% (endotoxemia) and 0% (controls). Both septic groups became hyperdynamic. While neither sepsis nor volume resuscitation strategy was associated with altered hepatic or muscle mitochondrial complex I- and II-dependent respiration, non-survivors had lower hepatic complex II-dependent respiratory control ratios (2.6 +/- 0.7, vs. 3.3 +/- 0.9 in survivors; P = 0.01). Histology revealed moderate damage in all organs, colloid plaques in lung tissue of high-volume groups, and severe kidney damage in endotoxin high-volume animals. Conclusions High-volume resuscitation including HES in experimental peritonitis and endotoxemia increased mortality despite better initial hemodynamic stability. This suggests that the strategy of early fluid management influences outcome in sepsis. The high mortality was not associated with reduced mitochondrial complex I- or II-dependent muscle and hepatic respiration

    Mesh shrinkage and pain in laparoscopic ventral hernia repair: a randomized clinical trial comparing suture versus tack mesh fixation

    Get PDF
    Mesh fixation during laparoscopic ventral hernia repair can be performed using transfascial sutures or metal tacks. The aim of the present study is to compare mesh shrinkage and pain between two different techniques of mesh fixation in a prospective randomized trial

    Indocyanine green plasma disappearance rate during the anhepatic phase of orthotopic liver transplantation

    Get PDF
    Non-invasive pulse spectrophotometry to measure indocyanine green (ICG) elimination correlates well with the conventional invasive ICG clearance test. Nevertheless, the precision of this method remains unclear for any application, including small-for-size liver remnants. We therefore measured ICG plasma disappearance rate (PDR) during the anhepatic phase of orthotopic liver transplantation using pulse spectrophotometry. Measurements were done in 24 patients. The median PDR after exclusion of two outliers and two patients with inconstant signal was 1.55%/min (95% confidence interval [CI]=0.8-2.2). No correlation with patient age, gender, body mass, blood loss, administration of fresh frozen plasma, norepinephrine dose, postoperative albumin (serum), or difference in pre and post transplant body weight was detected. In conclusion, we found an ICG-PDR different from zero in the anhepatic phase, an overestimation that may arise in particular from a redistribution into the interstitial space. If ICG pulse spectrophotometry is used to measure functional hepatic reserve, the verified average difference from zero (1.55%/min) determined in our study needs to be taken into account

    Fecal calprotectin correlates more closely with the simple endoscopic score for Crohn's Disease (SES-CD) than CRP, blood leukocytes, and the CDAI

    Full text link
    OBJECTIVES:Studies evaluating the correlation between the widely used Simple Endoscopic Score for Crohn's disease (SES-CD) and noninvasive markers are scarce. The aim of this study was to evaluate the correlation between the SES-CD and fecal calprotectin, C-reactive protein (CRP), blood leukocytes, and the Crohn's disease activity index (CDAI).METHODS:Crohn's disease patients undergoing complete ileocolonoscopy were prospectively enrolled and scored independently according to the SES-CD and the CDAI. SES-CD was defined as follows: inactive 0-3; mild 4-10; moderate 11-19; and high >/=20.RESULTS:Values in CD patients (n=140 ileocolonoscopies) compared with controls (n=43) are as follows: calprotectin, 334+/-322 vs. 18+/-5 mug/g; CRP, 26+/-29 vs. 3+/-2 mg/l; and blood leukocytes, 9.1+/-3.4 vs. 5.4+/-1.9 g/l (all P/=150.CONCLUSIONS:Fecal calprotectin correlated closest with SES-CD, followed by CRP, blood leukocytes, and the CDAI. Furthermore, fecal calprotectin was the only marker that reliably discriminated inactive from mild, moderate, and highly active disease, which underlines its usefulness for activity monitoring

    Carbon Dioxide Embolism Associated With Transanal Total Mesorectal Excision Surgery: A Report From the International Registries

    No full text
    BACKGROUND: Carbon dioxide embolus has been reported as a rare but clinically important risk associated with transanal total mesorectal excision surgery. To date, there exists limited data describing the incidence, risk factors, and management of carbon dioxide embolus in transanal total mesorectal excision. OBJECTIVE: This study aimed to obtain data from the transanal total mesorectal excision registries to identify trends and potential risk factors for carbon dioxide embolus specific to this surgical technique. DESIGN: Contributors to both the LOREC and OSTRiCh transanal total mesorectal excision registries were invited to report their incidence of carbon dioxide embolus. Case report forms were collected detailing the patient-specific and technical factors of each event. SETTINGS: The study was conducted at the collaborating centers from the international transanal total mesorectal excision registries. MAIN OUTCOME MEASURES: Characteristics and outcomes of patients with carbon dioxide embolus associated with transanal mesorectal excision were measured. RESULTS: Twenty-five cases were reported. The incidence of carbon dioxide embolus during transanal total mesorectal excision is estimated to be ≈0.4% (25/6375 cases). A fall in end tidal carbon dioxide was noted as the initial feature in 22 cases, with 13 (52%) developing signs of hemodynamic compromise. All of the events occurred in the transanal component of dissection, with mean (range) insufflation pressures of 15 mm Hg (12-20 mm Hg). Patients were predominantly (68%) in a Trendelenburg position, between 30° and 45°. Venous bleeding was reported in 20 cases at the time of carbon dioxide embolus, with periprostatic veins documented as the most common site (40%). After carbon dioxide embolus, 84% of cases were completed after hemodynamic stabilization. Two patients required cardiopulmonary resuscitation because of cardiovascular collapse. There were no deaths. LIMITATIONS: This is a retrospective study surveying reported outcomes by surgeons and anesthetists. CONCLUSIONS: Surgeons undertaking transanal total mesorectal excision must be aware of the possibility of carbon dioxide embolus and its potential risk factors, including venous bleeding (wrong plane surgery), high insufflation pressures, and patient positioning. Prompt recognition and management can limit the clinical impact of such events. See Video Abstract at http://links.lww.com/DCR/A961
    corecore