7 research outputs found

    Motor Developmental Delay After Cardiac Surgery in Children With a Critical Congenital Heart Defect: A Systematic Literature Review and Meta-analysis

    No full text
    PURPOSE: To systematically review evidence regarding the severity and prevalence of motor development in children with a critical congenital heart defect (CCHD) without underlying genetic anomalies. SUMMARY OF KEY POINTS: Twelve percent of all included studies reported abnormal mean motor developmental scores, and 38% reported below average motor scores. Children with single-ventricle physiology, especially those with hypoplastic left heart syndrome, had the highest severity and prevalence of motor delay, particularly at 0 to 12 months. Most included studies did not differentiate between gross and fine motor development, yet gross motor development was more affected. RECOMMENDATIONS FOR CLINICAL PRACTICE: We recommend clinicians differentiate between the type of heart defect, fine and gross motor development, and the presence of genetic anomalies. Furthermore, increased knowledge about severity and prevalence will enable clinicians to tailor their interventions to prevent motor development delays in CCHD

    Multi-center evaluation of Cepheid Xpert® Xpress SARS-CoV-2/Flu/RSV molecular point-of-care test.

    No full text
    The Xpert® Xpress SARS-CoV-2/Flu/RSV assay was compared to three reference assays at three Dutch medical microbiology laboratories. An external quality assessment panel consisting of 16 specimens containing SARS-CoV-2, influenza viruses, RSV or human seasonal coronaviruses, or a combination thereof were used. Clinical specimens containing SARS-CoV-2 (n = 57), influenza viruses (n = 21) or RSV (n = 12), at a wide range of relevant concentrations were used. One laboratory also tested zoonotic avian and swine influenza viruses, and eight relevant SARS-CoV-2 variants

    Multi-center evaluation of cepheid xpert® xpress SARS-CoV-2 point-of-care test during the SARS-CoV-2 pandemic.

    No full text
    Contains fulltext : 220114.pdf (Publisher’s version ) (Closed access)BACKGROUND: With the outbreak of SARS-CoV-2, rapid diagnostics are paramount to contain the current pandemic. The routinely used realtime RT-PCR is sensitive, specific and able to process large batches of samples. However, turnaround time is long and in cases where fast obtained results are critical, molecular point of care tests (POCT) can be an alternative. Here we report on a multicenter evaluation of the Cepheid Xpert Xpress SARS-CoV-2 point-of-care test. STUDY DESIGN: The Xpert Xpress SARS-CoV-2 assay was evaluated against the routine in-house real-time RT-PCR assays in three medical microbiology laboratories in The Netherlands. A sensitivity and specificity panel was tested consisting of a dilution series of SARS-CoV-2 and ten samples containing SARS-CoV-2 and a range of other seasonal respiratory viruses. Additionally, 58 samples of patients positive for SARS-CoV-2 with different viral loads and 30 tested negative samples in all three Dutch laboratories using an in-house RT-PCR, were evaluated using Cepheids Xpert Xpress SARS-CoV-2 cartridges. RESULTS: Xpert Xpress SARS-CoV-2 point of care test showed equal performance compared to routine in-house testing with a limit of detection (LOD) of 8.26 copies/mL. Other seasonal respiratory viruses were not detected. In clinical samples Xpert Xpress SARS-CoV-2 reaches an agreement of 100 % compared to all in-house RT-PCRs CONCLUSION: Cepheids GeneXpert Xpert Xpress SARS-CoV-2 is a valuable addition for laboratories in situations where rapid and accurate diagnostics are of the essence

    Privacy for the Homo Digitalis: Proposal for a New Regulatory Framework for Data Protection in the Light of Big Data and the Internet of Things

    No full text
    The authors analyze innovations in data processing as a result of developments such as 'big data' and the 'Internet of Things' and discuss why these developments undermine the effectiveness and legitimacy of the current as well as upcoming EU data protection regime, thereby focusing on the private sector. The authors undertake a detailed analysis of key data processing principles used in the European data protection regime (purpose limitation, informational self-determination and data quality) and argue that due to social trends and technological developments the principle of purpose limitation should be abandoned as a separate criterion. Also, other principles (such as consent and the performance of an agreement) should no longer be recognised as independent legal grounds to legitimize data processing. The authors propose, instead, a test based on whether there is a legitimate interest for data collection and processing (as well as further processing) of data. The authors argue that such a test will provide for a more effective data protection regime that will have more legitimacy than the assessment under the existing legal regime that is primarily based on the purposes for which data may be collected and further used. Based on their analysis, the authors develop a framework to be used by companies as the principal (and only) test for the whole life cycle of personal data processing (collection, use, further use and destruction of data). This test has been drafted in such a way that it enables companies to comply with the new requirements under the upcoming EU General Data Protection Regulation, that will become effective in 2018. The authors conclude their analysis with proposals to increase the (effectiveness of) enforcement of the data protection rule
    corecore