96 research outputs found
Hospital Organization and Importance of an Interventional Radiology Inpatient Admitting Service:Italian Single-Center 3-year Experience
In June 2005 a Complex Operating Unit of
Interventional Radiology (COUIR), consisting of an outpatient
visit service, an inpatient admitting service with
four beds, and a day-hospital service with four beds was
installed at our department. Between June 2005 and May
2008, 1772 and 861 well-screened elective patients were
admitted to the inpatient ward of the COUIR and to the
Internal Medicine Unit (IMU) or Surgery Unit (SU) of our
hospital, respectively, and treated with IR procedures. For
elective patients admitted to the COUIR’s inpatient ward,
hospital stays were significantly shorter and differences
between reimbursements and costs were significantly
higher for almost all IR procedures compared to those for
patients admitted to the IMU and SU (Student’s t-test for
unpaired data, p\0.05). The results of the 3-year activity
show that the activation of a COUIR with an inpatient
admitting service, and the better organization of the patient
pathway that came with it, evidenced more efficient use of
resources, with the possibility for the hospital to save
money and obtain positive margins (differences between
reimbursements and costs). During 3 years of activity, the
inpatient admitting service of our COUIR yielded a positive
difference between reimbursements and effective costs
of €1,009,095.35. The creation of an inpatient IR service
and the admission of well-screened elective patients
allowed short hospitalization times, reduction of waiting
lists, and a positive economic outcome.
Keywords Inpatients Hospitalization Costs
Reimbursement
Imprinting vortices into antiferromagnets
Premi a l'excel·lència investigadora. Àmbit de les Ciències Tecnològiques. 2008The effect of imprinting symmetric and displaced vortex structures into an antiferromagnetic material is investigated in micron-sized disks consisting of exchange coupled ferromagnetic-antiferromagnetic bilayers. The imprint of displaced vortices manifests itself by the occurrence of a new type of asymmetric hysteresis loops characterized by curved, reversible, central sections with nonzero remanent magnetization. Such an imprint is achieved by cooling the disks through the blocking temperature of the system in small fields. Micromagnetic simulations reveal that asymmetric vortexlike loops naturally result from the competition between the different energies involved in the system
The Utility of Capsicum annuum L. in Internal Medicine and In Dentistry: A Comprehensive Review
Capsaicin is a chili peppers extract, genus Capsicum, commonly used as a food spice. Since ancient times, Capsaicin has been used as a "homeopathic remedy" for treating a wild range of pathological conditions but without any scientific knowledge about its action. Several studies have demonstrated its potentiality in cardiovascular, nephrological, nutritional, and other medical fields. Capsaicin exerts its actions thanks to the bond with transient receptor potential vanilloid subtype 1 (TRPV1). TRPV1 is a nociceptive receptor, and its activation starts with a neurosensitive impulse, responsible for a burning pain sensation. However, constant local application of Capsaicin desensitized neuronal cells and leads to relief from neuropathic pain. In this review, we analyze the potential adjuvant role of Capsaicin in the treatment of different pathological conditions either in internal medicine or dentistry. Moreover, we present our experience in five patients affected by oro-facial pain consequent to post-traumatic trigeminal neuropathy, not responsive to any remedy, and successfully treated with topical application of Capsaicin. The topical application of Capsaicin is safe, effective, and quite tolerated by patients. For these reasons, in addition to the already-proven beneficial actions in the internal field, it represents a promising method for the treatment of neuropathic oral diseases
Interfacial exchange-coupling induced chiral symmetry breaking of spin-orbit effects
We demonstrate that the interfacial exchange coupling in ferromagnetic/antiferromagnetic (FM/AFM) systems induces symmetry breaking of the spin-orbit (SO) effects. This has been done by studying the field and angle dependencies of anisotropic magnetoresistance and vectorial-resolved magnetization hysteresis loops, measured
simultaneously and reproduced with numerical simulations. We show how the induced unidirectional magnetic anisotropy at the FM/AFM interface results in strong asymmetric transport behaviors, which are chiral around the magnetization hard-axis direction. Similar asymmetric features are anticipated in other SO-driven phenomenaThis work was supported in part by the Spanish MINECO through Projects No. MAT2012-39308, No. FIS2013-40667-P, No. MAT2011-25598, and No. MAT2014-52477-C5-3-P, and by the Comunidad de Madrid through Project No. S2013/MIT-2850 (NANOFRONTMAG-CM). P.P. and A.B. acknowledge support through the Marie Curie AMAROUT EU Programme, and through MINECO “Juan de la Cierva” (JCI-2011-09602) and “Ramón y Cajal” contract
Full rehabilitation with nobel clinician® and procera implant bridge®: case report
Implant surgery has been changing in different ways following improvements of computer technologies. Since its beginning, according to the original procedures of
Branemårk system implants, guide-lines in
implants-supported prosthetic rehabilitation
have been founding on the placement of fixtures in a fairly upright position, after maxillary sinus floor elevation;
while in the case of interforaminal rehabilitation, an upright distal implant may need to be placed anterior to the mental foramina without nerve damage (although the consequence would have been bilateral cantilevers to provide good chewing capacity). Some authors have proposed engaging the molar/tuberosity area: Bahat and Venturelli demonstrated these areas reliable and predictable alternative to distal cantilever prostheses or sinus elevation procedures. In recent years, the immediate loading of tilted implants with a provisional restoration has been proposed for the treatment of the atrophic
maxilla. Tilted posterior implants in either arches could avoid (cantilever length) and provide to a better load distribution. Further studies have showed excellent outcomes for both tilted and axial implants; indeed this protocol allows to use longer implants, improve bone anchorage and avoid bone grafting procedures. Malò at al., in a retrospective clinical study, showed important results using two posterior tilted implants and two anterior
non-tilted ones in the so-called All-on-four technique
(Nobel Biocare, Göteborg, Sweden). Instead of the great loss of bone (amount and quality) in long-term edentuly the clinically documented computer-guided implantology software is able, through posterior tilted implants, to improve load distribution. Many authors have reported reduced surgical invasion (sinus grafting surgery is needless), shorter treatment time, lower cost, natural aesthetic profiles and functional bite
- …