17 research outputs found

    Goftte: A R package for assessing goodness-of-fit in proportional (sub) distributions hazards regression models

    No full text
    International audienceBackground and objectiveIn this paper, we introduce a new R package goftte for goodness-of-fit assessment based on cumulative sums of model residuals useful for checking key assumptions in the Cox regression and Fine and Gray regression models.MethodsMonte-Carlo methods are used to approximate the null distribution of cumulative sums of model residuals. To limit the computational burden, the main routines used to approximate the null distributions are implemented in a parallel C++ programming environment. Numerical studies are carried out to evaluate the empirical type I error rates of the different testing procedures. The package and the documentation are available to users from CRAN R repositories.ResultsResults from simulation studies suggested that all statistical tests implemented in goftte yielded excellent control of the type I error rate even with modest sample sizes with high censoring rates.ConclusionsAs compared to other R packages goftte provides new useful method for testing functionals, such as Anderson-Darling type test statistics for checking assumptions about proportional (sub-) distribution hazards. Approximations for the null distributions of test statistics have been validated through simulation experiments. Future releases will provide similar tools for checking model assumptions in multiplicative intensity models for recurrent data. The package may help to spread the use of recent advocated goodness-of-fit techniques in semiparametric regression for time-to-event data

    DOSIMAP: a high-resolution 2-D tissue equivalent dosemeter for linac QA and IMRT verification

    No full text
    International audienceNew generation of radiation therapy accelerators requires highly accurate dose measurements with high spatial resolution patterns. IMRT is especially demanding since the positioning accuracy of all the multi-leafs should be verified for each applied field and at any incidence. A new 2-D tissue equivalent dosemeter is presented with high spatial resolution that can fulfil these tasks. A plastic scintillator sheet is sandwiched between two polystyrene cubes, and the emitted light is observed by a high-resolution camera. A patented procedure allows efficient discrimination of the scintillation proportional to the dose from the parasitic Cerenkov radiation. This extraction made on the cumulated images taken during an irradiation field at a rate of 10 images s(-1) provides high-resolution mapping of the dose rate and cumulated dose in quasi real time. The dosemeter is tissue equivalent (ICRU-44) and works both for electrons and photons without complex parameter adjustment, since phantom and detector materials are identical. The calibration is simple and independent of the irradiation conditions (energy, fluence, quality and so on). The principle of the dosemeter and its calibration procedure are discussed in this paper. The results and, in particular, the dose depth profiles are compared with standard ionisation chamber measurements in polystyrene for both photons and electrons. Finally, the detector specifications are summarised and one example of complex IMRT field is discussed

    The DOSIMAP, a high spatial resolution tissue equivalent 2D dosimeter for LINAC QA and IMRT verification

    No full text
    The continual need for more accurate and effective techniques in radiation therapy makes it necessary to devise new control means combining high spatial resolution as well as high dose accuracy. Intensity modulated radio therapy (IMRT) allows highly conformed fields with high spatial gradient and therefore requires a precise monitoring of all the multileaf positions. In response to this need, the authors have developed a new 2D tissue equivalent dosimeter with high spatial resolution. A plastic scintillator sheet is sandwiched between two polystyrene blocks and the emitted light is captured by a high resolution camera. A newly developed procedure described herein allows efficient discrimination of the scintillation from the parasitic ÄŚerenkov radiation. This processing is applied on the cumulated image from a sequence of images taken during an irradiation field at a rate of 10 images/s. It provides a high resolution mapping of the cumulated dose in quasireal time. The dosimeter is tissue equivalent (ICRU-44) and works both for electrons and photons without complex parameter adjustment since phantom and detector materials are identical. Instrument calibration is simple and independent of the irradiation conditions (energy, fluence, quality, ...). In this article, the authors present the principle of the dosimeter and its calibration procedure. They compare the results obtained for photons and electron beams with ionization chamber measurements in polystyrene. Technical specifications such as accuracy and repeatability are precisely evaluated and discussed. Finally, they present different IMRT field measurements and compare DOSIMAP measurements to TPS simulations and dosimetric film profiles. The results confirm the excellent spatial resolution of the instrument and its capacity to inspect the leaf positions for each segment of a given field

    The DosiMap, a new 2D scintillating dosimeter for IMRT quality assurance: Characterization of two Cerenkov discrimination methods

    No full text
    New radiation therapy techniques such as IMRT present significant efficiency due to their highly conformal dose distributions. A consequence of the complexity of their dose distributions (high gradients, small irradiation fields, low dose distribution, ...) is the requirement for better precision quality assurance than in classical radiotherapy in order to compare the conformation of the delivered dose with the planned dose distribution and to guarantee the quality of the treatment. Currently this control is mostly performed by matrices of ionization chambers, diode detectors, dosimetric films, portal imaging, or dosimetric gels. Another approach is scintillation dosimetry, which has been developed in the last 15 years mainly through scintillating fiber devices. Despite having many advantages over other methods it is still at an experimental level for routine dosimetry because the ?erenkov radiation produced under irradiation represents an important stem effect. A new 2D water equivalent scintillating dosimeter, the DosiMap, and two different Cerenkov discrimination methods were developed with the collaboration of the Laboratoire de Physique Corpusculaire of Caen, the Comprehensive Cancer Center François Baclesse, and the ELDIM Co., in the frame of the MAESTRO European project. The DosiMap consists of a plastic scintillating sheet placed inside a transparent polystyrene phantom. The light distribution produced under irradiation is recorded by a CCD camera. Our first Cerenkov discrimination technique is subtractive. It uses a chessboard pattern placed in front of the scintillator, which provides a background signal containing only Cerenkov light. Our second discrimination technique is colorimetric. It performs a spectral analysis of the light signal, which allows the unfolding of the Cerenkov radiation and the scintillation. Tests were carried out with our DosiMap prototype and the performances of the two discrimination methods were assessed. The comparison of the dose measurements performed with the DosiMap and with dosimetric films for three different irradiation configurations showed discrepancies smaller than 3.5% for a 2 mm spatial resolution. Two innovative discrimination solutions were demonstrated to separate the scintillation from the Cerenkov radiation. It was also shown that the Dosi- Map, which is water equivalent, fast, and user friendly, is a very promising tool for radiotherapy quality assurance
    corecore