343 research outputs found

    Evaluating the performance of survey-based operational management procedures

    Get PDF
    The design and evaluation of survey-based management strategies is addressed in this article, using three case-study fisheries: North Sea herring, Bay of Biscay anchovy and North Sea cod, with a brief history and the main management issues with each fishery outlined. A range of operational management procedures for the case study stocks were designed and evaluated using trends that may be derived from survey indices (spawner biomass, year-class strength and total mortality) with an array of simple and more structured observation error regimes simulated. Model-free and model-based indicators of stock status were employed in the management procedures. On the basis of stochastic stock-specific simulations, we identified the following key determinants of successful management procedures: (i) adequate specification of the stock-recruit relationship (model structure, parameter estimates and variability), (ii) knowledge of the magnitude and structure of the variation in the survey indices, and (iii) explication of the particular management objectives, when assessing management performance. More conservative harvesting strategies are required to meet specified targets in the presence of increasing stochasticity, due to both process and observation error. It was seen that survey-based operational management procedures can perform well in the absence of commercial data, and can also inform aspects of survey design with respect to acceptable levels of error or bias in the surveys

    Evaluation of a Fiber-Optic Based Pulsed Laser System for Fluorescence Spectroscopy

    Get PDF
    A fiber optic based continous wave laser setup has been developed to record the 5-aminolevulinic (5-ALA) induced Protoporfyrin IX (PpIX) fluorescence signals from cerebral gliomas. To reduce the energy delivered to the tissue as well as suppression of the ambient lamp artifact from the recorded spectra, a pulsed laser setup has been developed and evaluated. This setup has been calibrated and first evaluations were performed on the 5-ALA treated skin showing PpIX fluorescence peaks from the ALA treated skin at 635 and 704 nm wavelengths. The system controls laser pulses through a computer interface and labview software package. Pulses as short as 50 ms over a period time of 500 ms are generated and optimally detected. The results from primary measurements on skin show an effective suppression of room fluorescent lamp artifact from the recorded spectra

    Early neoplastic and metastatic mammary tumours of transgenic mice detected by 5-aminolevulinic acid-stimulated protoporphyrin IX accumulation

    Get PDF
    A photodynamic technique for human breast cancer detection founded upon the ability of tumour cells to rapidly accumulate the fluorescent product protoporphyrin IX (PpIX) has been applied to transgenic mouse models of mammary tumorigenesis. A major goal of this investigation was to determine whether mouse mammary tumours are reliable models of human disease in terms of PpIX accumulation, for future mechanistic and therapeutic studies. The haeme substrate 5-aminolevulinic acid (5-ALA) (200 mg kg−1) was administered to mouse strains that develop mammary tumours of various histological subtypes upon expression of the transgenic oncogenes HRAS, Polyoma Virus middle T antigen, or Simian Virus 40 large T antigen in the mammary gland. Early neoplastic lesions, primary tumours and metastases showed consistent and rapid PpIX accumulation compared to the normal surrounding tissues, as evidenced by red fluorescence (635 nm) when the tumours were directly illuminated with blue light (380–440 nm). Detection of mouse mammary tumours at the stage of ductal carcinoma in situ by red fluorescence emissions suggests that enhanced PpIX synthesis is a good marker for early tumorigenic processes in the mammary gland. We propose the mouse models provide an ideal experimental system for further investigation of the early diagnostic and therapeutic potential of 5-ALA-stimulated PpIX accumulation in human breast cancer patients

    Interview 27e Bestuur der B.I.L.

    Get PDF
    Het 27e bestuur der B.I.L heeft imiddels haar intrede gedaan. Om de bestuursleden beter te leren kennen stellen zij zichzelf hier aan de hand van een aantal vragen aan de lezers voor

    In vivo quantification of photosensitizer fluorescence in the skin-fold observation chamber using dual-wavelength excitation and NIR imaging

    Get PDF
    A major challenge in biomedical optics is the accurate quantification of in vivo fluorescence images. Fluorescence imaging is often used to determine the pharmacokinetics of photosensitizers used for photodynamic therapy. Often, however, this type of imaging does not take into account differences in and changes to tissue volume and optical properties of the tissue under interrogation. To address this problem, a ratiometric quantification method was developed and applied to monitor photosensitizer meso-tetra (hydroxyphenyl) chlorin (mTHPC) pharmacokinetics in the rat skin-fold observation chamber. The method employs a combination of dual-wavelength excitation and dualwavelength detection. Excitation and detection wavelengths were selected in the NIR region. One excitation wavelength was chosen to be at the Q band of mTHPC, whereas the second excitation wavelength was close to its absorption minimum. Two fluorescence emission bands were used; one at the secondary fluorescence maximum of mTHPC centered on 720 nm, and one in a region of tissue autofluorescence. The first excitation wavelength was used to excite the mTHPC and autofluorescence and the second to excite only autofluorescence, so that this could be subtracted. Subsequently, the autofluorescence-corrected mTHPC image was divided by the autofluorescence signal to correct for variations in tissue optical properties. This correction algorithm in principle results in a linear relation between the corrected fluorescence and photosensitizer concentration. The limitations of the presented method and comparison with previously published and validated techniques are discussed

    Survey on prevalence and risk factors on HIV-1 among pregnant women in North-Rift, Kenya: a hospital based cross-sectional study conducted between 2005 and 2006

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The HIV/AIDS epidemic in Kenya is a major public-health problem. Estimating the prevalence of HIV in pregnant women provides essential information for an effective implementation of HIV/AIDS control measures and monitoring of HIV spread within a country. The objective of this study was to determine the prevalence of HIV infection, risk factors for HIV/AIDS and immunologic (lymphocyte profile) characteristics among pregnant women attending antenatal clinics in three district hospitals in North-Rift, Kenya.</p> <p>Methods</p> <p>Blood samples were collected from pregnant women attending antenatal clinics in three district hospitals (Kitale, Kapsabet and Nandi Hills) after informed consent and pre-test counseling. The samples were tested for HIV antibodies as per the guidelines laid down by Ministry of Health, Kenya. A structured pretested questionnaire was used to obtain demographic data. Lymphocyte subset counts were quantified by standard flow cytometry.</p> <p>Results</p> <p>Of the 4638 pregnant women tested, 309 (6.7%) were HIV seropositive. The majority (85.1%) of the antenatal attendees did not know their HIV status prior to visiting the clinic for antenatal care. The highest proportion of HIV infected women was in the age group 21–25 years (35.5%). The 31–35 age group had the highest (8.5%) HIV prevalence, while women aged more than 35 years had the lowest (2.5%).</p> <p>Women in a polygamous relationship were significantly more likely to be HIV infected as compared to those in a monogamous relationship (p = 0.000). The highest HIV prevalence (6.3%) was recorded among antenatal attendees who had attended secondary schools followed by those with primary and tertiary level of education (6% and 5% respectively). However, there was no significant relationship between HIV seropositivity and the level of education (p = 0.653 and p = 0.469 for secondary and tertiary respectively). The mean CD4 count was 466 cells/mm<sup>3 </sup>(9–2000 cells/mm<sup>3</sup>). Those that had less than 200 cells/mm<sup>3 </sup>accounted for 14% and only nine were on antiretroviral therapy.</p> <p>Conclusion</p> <p>Seroprevalence of HIV was found to be consistent with the reports from the national HIV sentinel surveys. Enumeration of T-lymphocyte (CD4/8) should be carried out routinely in the antenatal clinics for proper timing of initiation of antiretroviral therapy among HIV infected pregnant women.</p
    corecore