16,130 research outputs found

    ROSAT Detection and High Precision Localization of X-ray Sources in the November 19, 1978 Gamma-Ray Burst Error Box

    Get PDF
    We report on observations of the 1978, November 19 Gamma-Ray Burst source, performed with the ROSAT X-ray HRI experiment. Two sources were detected, one of which is possibly variable. The latter source is identical to the source discovered in 1981 by the EINSTEIN satellite, and recently detected by ASCA. The precise localization of these sources is given, and our data are compared with optical, radio and previous X-ray data.Comment: 10 pages with 2 figures, Accepted for publication in the Astrophysical Journal (Letters), Latex, aastex macros neede

    Higgs Limit and b->s gamma Constraints in Minimal Supersymmetry

    Full text link
    New limits on the Higgs mass from LEP and new calculations on the radiative (penguin) decay of the b->s gamma branching ratio restrict the parameter space of the Constrained Minimal Supersymmetric Standard Model (CMSSM). We find that for the low tan(beta) scenario only one sign of the Higgs mixing parameter is allowed, while the high tan(beta scenario is practically excluded, if one requires all sparticles to be below 1 TeV and imposes radiative electroweak symmetry breaking as well as gauge and Yukawa coupling unification. For squarks between 1 and 2 TeV high tan(beta) scenarios are allowed. We consider especially a new high tan(beta)=64 scenario with triple unification of all Yukawa couplings of the third generation, which show an infrared fixed point behaviour. The upper limit on the mass of the lightest Higgs in the low (high) tan(beta) scenarios is 97+-6~(120+-2) GeV, where the errors originate predominantly from the uncertainty in the top mass.Comment: latex + 6 eps figs, 10 pages, IEKP-KA/98-08; References updated in replacement + 1 figure concerning triple Yukawa unification added for final publication in Phys. Let

    High field CdS detector for infrared radiation

    Get PDF
    New and highly sensitive method of detecting infrared irradiation makes possible solid state infrared detector which is more sensitive near room temperature than usual photoconductive low band gap semiconductor devices. Reconfiguration of high field domains in cadmium sulphide crystals provides basis for discovery

    Further search for a neutral boson with a mass around 9 MeV/c2

    Get PDF
    Two dedicated experiments on internal pair conversion (IPC) of isoscalar M1 transitions were carried out in order to test a 9 MeV/c2 X-boson scenario. In the 7Li(p,e+e-)8Be reaction at 1.1 MeV proton energy to the predominantly T=0 level at 18.15 MeV, a significant deviation from IPC was observed at large pair correlation angles. In the 11B(d,n e+e-)12C reaction at 1.6 MeV, leading to the 12.71 MeV 1+ level with pure T=0 character, an anomaly was observed at 9 MeV/c2. The compatibility of the results with the scenario is discussed.Comment: 12 pages, 5 figures, 2 table

    High field CdS detector for infrared radiation

    Get PDF
    An infrared radiation detector including a cadmium sulfide platelet having a cathode formed on one of its ends and an anode formed on its other end is presented. The platelet is suitably doped such that stationary high-field domains are formed adjacent the cathode when based in the negative differential conductivity region. A negative potential is applied to the cathode such that a high-field domain is formed adjacent to the cathode. A potential measuring probe is located between the cathode and the anode at the edge of the high-field domain and means are provided for measuring the potential at the probe whereby this measurement is indicative of the infrared radiation striking the platelet

    The coupling of a hearing aid loudspeaker membrane to visco-thermal air layers

    Get PDF
    Hearing aids and their components are becoming smaller. This presents new problems for the acoustical components, such as the loudspeaker. A circular membrane of a hearing aid loudspeaker is modeled in this paper. Neglecting air influences, the membrane and its suspension behave as a mass spring system. However, under operating conditions, thin layers of air on both sides of the membrane influence its behavior. Air can enter and leave these layers at certain locations on the circular edge of the layer. Since these air layers are thin, visco-thermal effects may have to be taken into account. Therefore, the air layers are not modeled by the wave equation, but by the low reduced frequency model that takes these visco-thermal effects into account. The equations of this model are solved in a polar coordinate system, using a wave-based method. The other acoustical parts of the hearing aid loudspeaker, and the membrane itself are modeled by simple lumped models. The emphasis in this paper is on the coupling of the viscothermal air layer model to the mechanical model of the membrane. Coupling of the air layer to other acoustical parts by using an impedance as boundary condition for the layer model, is also described. The resulting model is verified by experiments. The model and the measurements match reasonably well, considering the level of approximation with lumped parts

    Field-Effect Transistors on Tetracene Single Crystals

    Full text link
    We report on the fabrication and electrical characterization of field-effect transistors at the surface of tetracene single crystals. We find that the mobility of these transistors reaches the room-temperature value of $0.4 \ cm^2/Vs$. The non-monotonous temperature dependence of the mobility, its weak gate voltage dependence, as well as the sharpness of the subthreshold slope confirm the high quality of single-crystal devices. This is due to the fabrication process that does not substantially affect the crystal quality.Comment: Accepted by Appl. Phys. Lett, tentatively scheduled for publication in the November 24, 2003 issu

    Trajectory Deflection of Spinning Magnetic Microparticles, the Magnus Effect at the Microscale

    Get PDF
    The deflection due to the Magnus force of magnetic particles with a diameter of 80 micrometer dropping through fluids and rotating in a magnetic field was measured. With Reynolds number for this experiment around 1, we found trajectory deflections of the order of 1 degree, in agreement within measurement error with theory. This method holds promise for the sorting and analysis of the distribution in magnetic moment and particle diameter of suspensions of microparticles, such as applied in catalysis, or objects loaded with magnetic particles.Comment: 12 pages, 3 figures. Appendix with 6 figure

    Parallel single cell analysis on an integrated microfluidic platform for cell trapping, lysis and analysis

    Get PDF
    We report here a novel and easily scalable microfluidic platform for the parallel analysis of hundreds of individual cells, with controlled single cell trapping, followed by their lysis and subsequent retrieval of the cellular content for on-chip analysis. The device consists of a main channel and an array of shallow side channels connected to the main channel via trapping structures. Cells are individually captured in dam structures by application of a negative pressure from an outlet reservoir, lyzed on site and the cellular content controllably extracted and transported in the individual side channels for on-chip analysis.\u

    Dark matter from the scalar sector of 3-3-1 models without exotic electric charges

    Get PDF
    We show that three SU(2) singlet neutral scalars (two CP-even and one CP-odd) in the spectrum of models based on the gauge symmetry SU(3)_c X SU(3)_L X U(1)_X, which do not contain exotic electric charges, are realistic candidates for thermally generated self-interacting dark matter in the Universe, a type of dark matter that has been recently proposed in order to overcome some difficulties of collisionless cold dark matter models at the galactic scale. These candidates arise without introducing a new mass scale in the model and/or without the need for a discrete symmetry to stabilize them, but at the expense of tuning several combinations of parameters of the scalar potential.Comment: RevTeX, 11 pages. v2: typos corrected, one reference added. v3: clarifications added, four more references added. To appear in Europhys. Let
    corecore