56 research outputs found

    Total OH reactivity measurements using a new fast Gas Chromatographic Photo-Ionization Detector (GC-PID)

    Get PDF
    The primary and most important oxidant in the atmosphere is the hydroxyl radical (OH). Currently OH sinks, particularly gas phase reactions, are poorly constrained. One way to characterize the overall sink of OH is to measure directly the ambient loss rate of OH, the total OH reactivity. To date, direct measurements of total OH reactivity have been either performed using a Laser-Induced Fluorescence (LIF) system ("pump-and-probe" or "flow reactor") or the Comparative Reactivity Method (CRM) with a Proton-Transfer-Reaction Mass Spectrometer (PTR-MS). Both techniques require large, complex and expensive detection systems. This study presents a feasibility assessment for CRM total OH reactivity measurements using a new detector, a Gas Chromatographic Photoionization Detector (GC-PID). Such a system is smaller, more portable, less power consuming and less expensive than other total OH reactivity measurement techniques. <br><br> Total OH reactivity is measured by the CRM using a competitive reaction between a reagent (here pyrrole) with OH alone and in the presence of atmospheric reactive molecules. The new CRM method for total OH reactivity has been tested with parallel measurements of the GC-PID and the previously validated PTR-MS as detector for the reagent pyrrole during laboratory experiments, plant chamber and boreal field studies. Excellent agreement of both detectors was found when the GC-PID was operated under optimum conditions. Time resolution (60–70 s), sensitivity (LOD 3–6 s<sup>−1</sup>) and overall uncertainty (25% in optimum conditions) for total OH reactivity were similar to PTR-MS based total OH reactivity measurements. One drawback of the GC-PID system was the steady loss of sensitivity and accuracy during intensive measurements lasting several weeks, and a possible toluene interference. Generally, the GC-PID system has been shown to produce closely comparable results to the PTR-MS and thus in suitable environments (e.g. forests) it presents a viably economical alternative for groups interested in total OH reactivity observations

    Visual contribution to postural stability: Interaction between target fixation or tracking and static or dynamic large-field stimulus

    Full text link
    Stationary visual information has a stabilizing effect on posture, whereas moving visual information is destabilizing. We compared the influence of a stationary or moving fixation point to the influence of stationary or moving large-field stimulation, as well as the interaction between a fixation point and a large-field stimulus. We recorded body sway in 20 healthy subjects who were fixating a stationary or oscillating dot (vertical or horizontal motion, 1/3Hz, +/-12 degrees amplitude, distance 96cm). In addition, a large-field random dot pattern (extension: approximately 80x70 degrees ) was stationary, moving or absent. Visual fixation of a stationary dot in darkness did not reduce antero-posterior (AP) sway compared to the situation in total darkness, but slightly reduced lateral sway at frequencies below 0.5Hz. In contrast, fixating a stationary dot on a stationary large-field pattern reduced both AP and lateral body sway at all frequencies (0.1-2Hz). Ocular tracking of the oscillating dot caused a peak in body sway at 1/3Hz, i.e. the stimulus frequency, but there was no influence of large-field stimulus at this frequency. A stationary large-field pattern, however, reduced AP and lateral sway at frequencies between 0.1 and 2Hz when subjects tracked a moving dot, compared to tracking in darkness. Our results demonstrate that a stationary large-field pattern has a stabilizing effect in all conditions, independent of whether the eyes are fixing on a stationary target or tracking a moving target

    The future of hybrid imaging—part 2: PET/CT

    Get PDF
    Since the 1990s, hybrid imaging by means of software and hardware image fusion alike allows the intrinsic combination of functional and anatomical image information. This review summarises the state-of-the-art of dual-modality imaging with a focus on clinical applications. We highlight selected areas for potential improvement of combined imaging technologies and new applications. In the second part, we briefly review the background of dual-modality PET/CT imaging, discuss its main applications and attempt to predict technological and methodological improvements of combined PET/CT imaging. After a decade of clinical evaluation, PET/CT will continue to have a significant impact on patient management, mainly in the area of oncological diseases. By adopting more innovative acquisition schemes and data processing PET/CT will become a fast and dose-efficient imaging method and an integral part of state-of-the-art clinical patient management

    Small-animal SPECT and SPECT/CT: application in cardiovascular research

    Get PDF
    Preclinical cardiovascular research using noninvasive radionuclide and hybrid imaging systems has been extensively developed in recent years. Single photon emission computed tomography (SPECT) is based on the molecular tracer principle and is an established tool in noninvasive imaging. SPECT uses gamma cameras and collimators to form projection data that are used to estimate (dynamic) 3-D tracer distributions in vivo. Recent developments in multipinhole collimation and advanced image reconstruction have led to sub-millimetre and sub-half-millimetre resolution SPECT in rats and mice, respectively. In this article we review applications of microSPECT in cardiovascular research in which information about the function and pathology of the myocardium, vessels and neurons is obtained. We give examples on how diagnostic tracers, new therapeutic interventions, pre- and postcardiovascular event prognosis, and functional and pathophysiological heart conditions can be explored by microSPECT, using small-animal models of cardiovascular disease

    The Changing Landscape for Stroke\ua0Prevention in AF: Findings From the GLORIA-AF Registry Phase 2

    Get PDF
    Background GLORIA-AF (Global Registry on Long-Term Oral Antithrombotic Treatment in Patients with Atrial Fibrillation) is a prospective, global registry program describing antithrombotic treatment patterns in patients with newly diagnosed nonvalvular atrial fibrillation at risk of stroke. Phase 2 began when dabigatran, the first non\u2013vitamin K antagonist oral anticoagulant (NOAC), became available. Objectives This study sought to describe phase 2 baseline data and compare these with the pre-NOAC era collected during phase 1. Methods During phase 2, 15,641 consenting patients were enrolled (November 2011 to December 2014); 15,092 were eligible. This pre-specified cross-sectional analysis describes eligible patients\u2019 baseline characteristics. Atrial fibrillation disease characteristics, medical outcomes, and concomitant diseases and medications were collected. Data were analyzed using descriptive statistics. Results Of the total patients, 45.5% were female; median age was 71 (interquartile range: 64, 78) years. Patients were from Europe (47.1%), North America (22.5%), Asia (20.3%), Latin America (6.0%), and the Middle East/Africa (4.0%). Most had high stroke risk (CHA2DS2-VASc [Congestive heart failure, Hypertension, Age  6575 years, Diabetes mellitus, previous Stroke, Vascular disease, Age 65 to 74 years, Sex category] score  652; 86.1%); 13.9% had moderate risk (CHA2DS2-VASc = 1). Overall, 79.9% received oral anticoagulants, of whom 47.6% received NOAC and 32.3% vitamin K antagonists (VKA); 12.1% received antiplatelet agents; 7.8% received no antithrombotic treatment. For comparison, the proportion of phase 1 patients (of N = 1,063 all eligible) prescribed VKA was 32.8%, acetylsalicylic acid 41.7%, and no therapy 20.2%. In Europe in phase 2, treatment with NOAC was more common than VKA (52.3% and 37.8%, respectively); 6.0% of patients received antiplatelet treatment; and 3.8% received no antithrombotic treatment. In North America, 52.1%, 26.2%, and 14.0% of patients received NOAC, VKA, and antiplatelet drugs, respectively; 7.5% received no antithrombotic treatment. NOAC use was less common in Asia (27.7%), where 27.5% of patients received VKA, 25.0% antiplatelet drugs, and 19.8% no antithrombotic treatment. Conclusions The baseline data from GLORIA-AF phase 2 demonstrate that in newly diagnosed nonvalvular atrial fibrillation patients, NOAC have been highly adopted into practice, becoming more frequently prescribed than VKA in Europe and North America. Worldwide, however, a large proportion of patients remain undertreated, particularly in Asia and North America. (Global Registry on Long-Term Oral Antithrombotic Treatment in Patients With Atrial Fibrillation [GLORIA-AF]; NCT01468701

    Compensatory saccades in head impulse testing influence the dynamic visual acuity of patients with unilateral peripheral vestibulopathy1

    Full text link
    BACKGROUND Both the dynamic visual acuity (DVA) test and the video head-impulse test (vHIT) are fast and simple ways to assess peripheral vestibulopathy. After losing peripheral vestibular function, some patients show better DVA performance than others, suggesting good compensatory mechanisms. It seems possible that compensatory covert saccades could be responsible for improved DVA. OBJECTIVE To investigate VOR gain and compensatory saccades with vHIT and compare them to the DVA of patients with unilateral peripheral vestibulopathy. METHODS VOR gain deficit and compensatory saccades were measured with vHIT. VOR gain was calculated for each trial as mean eye velocity divided by mean head velocity during 4 samples between 24 ms - 40 ms after peak head acceleration. DVA was then assessed. VHIT was analyzed for percentage of covert saccades and for cumulative overt saccade amplitude. Twenty-four patients with unilateral vestibular deficit were included. A control group of 113 healthy subjects provided normal data. RESULTS On the affected side, pathologic values for DVA (mean 0.83 logMAR±0.25 SD) and VOR gain (mean 0.16±0.13) were obtained, whereas the healthy side showed normal values (0.53 logMAR±0.15 for DVA and 0.89±0.18 for VOR gain). Yet, DVA performance on the affected side was significantly better in patients with higher covert saccade percentage (p = 0.012) and lower cumulative overt saccade amplitude (p < 0.001). CONCLUSION Compensatory covert saccades seen in vHIT correlate with improved performance of DVA-testing in patients with unilateral peripheral vestibular loss. Hence, in addition to testing peripheral vestibulopathy, our results indicate a way for assessing rehabilitatory compensation in such patients by DVA in addition to vHIT

    Assessment of Tumor Size Reduction Improves Outcome Prediction of Positron Emission Tomography/Computed Tomography After Chemotherapy in Advanced-Stage Hodgkin Lymphoma

    No full text
    Purpose Positron emission tomography (PET) after chemotherapy can guide consolidating radiotherapy in advanced-stage Hodgkin lymphoma (HL). This analysis aims to improve outcome prediction by integrating additional criteria derived by computed tomography (CT). Patients and Methods The analysis set consisted of 739 patients with residues > 2.5 cm after chemotherapy from a total of 2,126 patients treated in the HD15 trial (HD15 for advanced stage Hodgkin's disease: Quality assurance protocol for reduction of toxicity and the prognostic relevance of fluorodeoxyglucose-positron-emission tomography [FDG-PET] in the first-line treatment of advanced-stage Hodgkin's disease) performed by the German Hodgkin Study Group. A central panel performed image analysis and interpretation of CT scans before and after chemotherapy as well as PET scans after chemotherapy. Prognosis was evaluated by using progression-free survival (PFS); groups were compared with the log-rank test. Potential prognostic factors were investigated by using receiver operating characteristic analysis and logistic regression. Results In all, 548 (74%) of 739 patients had PET-negative residues after chemotherapy; these patients did not receive additional radiotherapy and showed a 4-year PFS of 91.5%. The 191 PET-positive patients (26%) receiving additional radiotherapy had a 4-year PFS of 86.1% (P = .022). CT alone did not allow further separation of patients in partial remission by risk of recurrence (P = .9). In the subgroup of the 54 PET-positive patients with a relative reduction of less than 40%, the risk of progression or relapse within the first year was 23.1% compared with 5.3% for patients with a larger reduction (difference, 17.9%; 95% CI, 5.8% to 30%). Conclusion Patients with HL who have PET-positive residual disease after chemotherapy and poor tumor shrinkage are at high risk of progression or relapse
    corecore