285 research outputs found
Visually guided adjustments of body posture in the roll plane
Body position relative to gravity is continuously updated to prevent falls. Therefore, the brain integrates input from the otoliths, truncal graviceptors, proprioception and vision. Without visual cues estimated direction of gravity mainly depends on otolith input and becomes more variable with increasing roll-tilt. Contrary, the discrimination threshold for object orientation shows little modulation with varying roll orientation of the visual stimulus. Providing earth-stationary visual cues, this retinal input may be sufficient to perform self-adjustment tasks successfully, with resulting variability being independent of whole-body roll orientation. We compared conditions with informative (earth-fixed) and non-informative (body-fixed) visual cues. If the brain uses exclusively retinal input (if earth-stationary) to solve the task, trial-to-trial variability will be independent from the subject's roll orientation. Alternatively, central integration of both retinal (earth-fixed) and extra-retinal inputs will lead to increasing variability when roll-tilted. Subjects, seated on a motorized chair, were instructed to (1) align themselves parallel to an earth-fixed line oriented earth-vertical or roll-tilted 75° clockwise; (2) move a body-fixed line (aligned with the body-longitudinal axis or roll-tilted 75° counter-clockwise to it) by adjusting their body position until the line was perceived earth-vertical. At 75° right-ear-down position, variability increased significantly (p<0.05) compared to upright in both paradigms, suggesting that, despite the earth-stationary retinal cues, extra-retinal input is integrated. Self-adjustments in the roll-tilted position were significantly (p<0.01) more precise for earth-fixed cues than for body-fixed cues, underlining the importance of earth-stable visual cues when estimates of gravity become more variable with increasing whole-body rol
Spatial orientation in patients with chronic unilateral vestibular hypofunction is ipsilesionally distorted
OBJECTIVE Acute unilateral peripheral-vestibular hypofunction (UVH) shifts the subjective visual vertical (SVV) ipsilesionally, triggering central compensation that usually eliminates shifts when upright. We hypothesized that compensation is worse when roll-tilted. METHODS We quantified SVV errors and variability in different roll-tilted positions (0°, ±45°, ±90°) in patients with chronic UVH affecting the superior branch (SVN; n=4) or the entire (CVN; n=9) vestibular nerve. RESULTS Errors in SVN and CVN were not different. When roll-tilted ipsilesionally 45° (9.6±5.4° vs. -0.2±6.4°, patients vs. controls, p<0.001) and 90° (23.5±5.7° vs. 16.8±8.8°, p=0.003), the patient's SVV was shifted significantly towards the lesioned ear. When upright, only a trend was noted (3.6±2.2° vs. 0.0±1.2°, p=0.099); for contralesional roll-tilts shifts were not different from controls. Variability was larger for CVN than SVN (p=0.046). With increasing disease-duration, adjustment errors decayed for ipsilesional roll-tilt and upright (p⩜0.025). CONCLUSIONS The reason verticality perception was distorted for ipsilesional roll-tilts, may be the insufficient integration of contralesional otolith-input. Similar errors in SVN and CVN suggest a dominant utricular role in verticality perception, albeit the sacculus may improve precision of SVV estimates. SIGNIFICANCE With deficiencies in central compensation being roll-angle dependent, extending SVV-testing to roll-tilted positions may improve identifying patients with chronic UVH
Total OH reactivity measurements using a new fast Gas Chromatographic Photo-Ionization Detector (GC-PID)
The primary and most important oxidant in the atmosphere is the hydroxyl radical (OH). Currently OH sinks, particularly gas phase reactions, are poorly constrained. One way to characterize the overall sink of OH is to measure directly the ambient loss rate of OH, the total OH reactivity. To date, direct measurements of total OH reactivity have been either performed using a Laser-Induced Fluorescence (LIF) system ("pump-and-probe" or "flow reactor") or the Comparative Reactivity Method (CRM) with a Proton-Transfer-Reaction Mass Spectrometer (PTR-MS). Both techniques require large, complex and expensive detection systems. This study presents a feasibility assessment for CRM total OH reactivity measurements using a new detector, a Gas Chromatographic Photoionization Detector (GC-PID). Such a system is smaller, more portable, less power consuming and less expensive than other total OH reactivity measurement techniques. <br><br> Total OH reactivity is measured by the CRM using a competitive reaction between a reagent (here pyrrole) with OH alone and in the presence of atmospheric reactive molecules. The new CRM method for total OH reactivity has been tested with parallel measurements of the GC-PID and the previously validated PTR-MS as detector for the reagent pyrrole during laboratory experiments, plant chamber and boreal field studies. Excellent agreement of both detectors was found when the GC-PID was operated under optimum conditions. Time resolution (60â70 s), sensitivity (LOD 3â6 s<sup>â1</sup>) and overall uncertainty (25% in optimum conditions) for total OH reactivity were similar to PTR-MS based total OH reactivity measurements. One drawback of the GC-PID system was the steady loss of sensitivity and accuracy during intensive measurements lasting several weeks, and a possible toluene interference. Generally, the GC-PID system has been shown to produce closely comparable results to the PTR-MS and thus in suitable environments (e.g. forests) it presents a viably economical alternative for groups interested in total OH reactivity observations
Antihysteresis of perceived longitudinal body axis during continuous quasi-static whole-body rotation in the earth-vertical roll plane
Estimation of subjective whole-body tilt in stationary roll positions after rapid rotations shows hysteresis. We asked whether this phenomenon is also present during continuous quasi-static whole-body rotation and whether gravitational cues are a major contributing factor. Using a motorized turntable, 8 healthy subjects were rotated continuously about the earth-horizontal naso-occipital axis (earth-vertical roll plane) and the earth-vertical naso-occipital axis (earth-horizontal roll plane). In both planes, three full constant velocity rotations (2°/s) were completed in clockwise and counterclockwise directions (acceleration=0.05°/s2, velocity plateau reached after 40s). Subjects adjusted a visual line along the perceived longitudinal body axis (pLBA) every 2s. pLBA deviation from the longitudinal body axis was plotted as a function of whole-body roll position, and a sine function was fitted. At identical whole-body earth-vertical roll plane positions, pLBA differed depending on whether the position was reached by a rotation from upright or by passing through upside down. After the first 360° rotation, pLBA at upright whole-body position deviated significantly in the direction of rotation relative to pLBA prior to rotation initiation. This deviation remained unchanged after subsequent full rotations. In contrast, earth-horizontal roll plane rotations resulted in similar pLBA before and after each rotation cycle. We conclude that the deviation of pLBA in the direction of rotation during quasi-static earth-vertical roll plane rotations reflects static antihysteresis and might be a consequence of the known static hysteresis of ocular counterroll: a visual line that is perceived that earth-vertical is expected to be antihysteretic, if ocular torsion is hystereti
Visual contribution to postural stability: Interaction between target fixation or tracking and static or dynamic large-field stimulus
Stationary visual information has a stabilizing effect on posture, whereas moving visual information is destabilizing. We compared the influence of a stationary or moving fixation point to the influence of stationary or moving large-field stimulation, as well as the interaction between a fixation point and a large-field stimulus. We recorded body sway in 20 healthy subjects who were fixating a stationary or oscillating dot (vertical or horizontal motion, 1/3Hz, +/-12 degrees amplitude, distance 96cm). In addition, a large-field random dot pattern (extension: approximately 80x70 degrees ) was stationary, moving or absent. Visual fixation of a stationary dot in darkness did not reduce antero-posterior (AP) sway compared to the situation in total darkness, but slightly reduced lateral sway at frequencies below 0.5Hz. In contrast, fixating a stationary dot on a stationary large-field pattern reduced both AP and lateral body sway at all frequencies (0.1-2Hz). Ocular tracking of the oscillating dot caused a peak in body sway at 1/3Hz, i.e. the stimulus frequency, but there was no influence of large-field stimulus at this frequency. A stationary large-field pattern, however, reduced AP and lateral sway at frequencies between 0.1 and 2Hz when subjects tracked a moving dot, compared to tracking in darkness. Our results demonstrate that a stationary large-field pattern has a stabilizing effect in all conditions, independent of whether the eyes are fixing on a stationary target or tracking a moving target
Mutation detection in cholestatic patients using microarray resequencing of ATP8B1 and ABCB11
© 2013 McKay KE et al. Background: Neonatal cholestasis is a common presentation of childhood liver diseases and can be a feature of various conditions including disorders of bile acid biogenesis and transport, various inborn errors of metabolism and perinatal infections. Some inherited metabolic diseases can be easily screened using biochemical assays, however many can only be accurately diagnosed by DNA sequencing. Fluorescent capillary Sanger sequencing (FS) is the gold standard method used by clinical laboratories for genetic diagnosis of many inherited conditions; however, it does have limitations. Recently microarray resequencing (MR) has been introduced into research and clinical practice as an alternative method for genetic diagnosis of heterogeneous conditions. In this report we compared the accuracy of mutation detection for MR with FS in a group of patients with 'low-normal' gamma glutamyl transpeptidase (gGT) cholestasis without known molecular diagnoses. Methods: 29 patient DNA samples were tested for mutations in the ATP8B1 and ABCB11 genes using both FS and MR. Other known causes of "low gGT cholestasis such as ARC syndrome and bile acid biosynthesis disorders were excluded. Results: Mutations were identified in 13/29 samples. In 3/29 samples FS and MR gave discordant results: MR had a false positive rate of 3.4% and a false negative rate of 7%. Conclusions: The major advantage of MR over FS is that multiple genes can be screened in one experiment, allowing rapid and cost-effective diagnoses. However, we have demonstrated that MR technology is limited in sensitivity. We therefore recommend that MR be used as an initial evaluation, with FS deployed when genetic and clinical or histopathological findings are discordant
Cold thermal irrigation decreases the ipsilateral gain of the vestibulo-ocular reflex
OBJECTIVES: During head rotations, neuronal firing rates increase in ipsilateral and decrease in contralateral vestibular afferents. At low accelerations, this "push-pull mechanism" is linear. At high accelerations, however, the change of firing rates is nonlinear in that the ipsilateral increase of firing rate is larger than the contralateral decrease. This mechanism of stronger ipsilateral excitation than contralateral inhibition during high-acceleration head rotation, known as Ewald's second law, is implemented within the nonlinear pathways. The authors asked whether caloric stimulation could provide an acceleration signal high enough to influence the contribution of the nonlinear pathway to the rotational vestibulo-ocular reflex gain (rVOR gain) during head impulses.
DESIGN: Caloric warm (44°C) and cold (24, 27, and 30°C) water irrigations of the left ear were performed in 7 healthy human subjects with the lateral semicircular canals oriented approximately earth-vertical (head inclined 30° from supine) and earth-horizontal (head inclined 30° from upright).
RESULTS: With the lateral semicircular canal oriented earth-vertical, the strongest cold caloric stimulus (24°C) significantly decreased the rVOR gain during ipsilateral head impulses, while all other irrigations, irrespective of head position, had no significant effect on rVOR gains during head impulses to either side.
CONCLUSIONS: Strong caloric irrigation, which can only be achieved with cold water, reduces the rVOR gain during ipsilateral head impulses and thus demonstrates Ewald's second law in healthy subjects. This unilateral gain reduction suggests that cold-water caloric irritation shifts the set point of the nonlinear relation between head acceleration and the vestibular firing rate toward a less acceleration-sensitive zone
Low fertility and population replacement in Scotland
It has been argued that Scotland faces population ageing and decline that will have potentially serious economic and social consequences, and that the origin of these processes lie in its low and declining fertility rates. After considering alternatives to the total period rate measure of fertility, empirical evidence and theoretical argument about low fertility and its consequences is briefly reviewed. The paper argues that low fertility in general may not be the problem it is often purported to be, that Scotland has relatively high fertility, and that pro-natalist policies are neither desirable nor necessary. It suggests that low fertility and population ageing may be viewed as positive developments, and that within Europe, Scotland is distinguished more by its excess of early deaths than by any shortage of births.Peer reviewe
The future of hybrid imagingâpart 1: hybrid imaging technologies and SPECT/CT
Since the 1990s, hybrid imaging by means of software and hardware image fusion alike allows the intrinsic combination of functional and anatomical image information. This review summarises in three parts the state-of-the-art of dual-technique imaging, with a focus on clinical applications. We will attempt to highlight selected areas of potential improvement of combined imaging technologies and new applications. In this first part, we briefly review the origins of hybrid imaging and comment on the status and future development of single photon emission tomography (SPECT)/computed tomography (CT). In short, we could predict that, within 10Â years, we may see all existing dual-technique imaging systems, including SPECT/CT, in clinical routine use worldwide. SPECT/CT, in particular, may evolve into a whole-body imaging technique with supplementary use in dosimetry applications
- âŠ