56 research outputs found
A next-generation liquid xenon observatory for dark matter and neutrino physics
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for weakly interacting massive particles, while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector
Projected sensitivity of the LUX-ZEPLIN experiment to the two-neutrino and neutrinoless double β decays of Xe 134
The projected sensitivity of the LUX-ZEPLIN (LZ) experiment to two-neutrino and neutrinoless double β decay of Xe134 is presented. LZ is a 10-tonne xenon time-projection chamber optimized for the detection of dark matter particles and is expected to start operating in 2021 at Sanford Underground Research Facility, USA. Its large mass of natural xenon provides an exceptional opportunity to search for the double β decay of Xe134, for which xenon detectors enriched in Xe136 are less effective. For the two-neutrino decay mode, LZ is predicted to exclude values of the half-life up to 1.7×1024 years at 90% confidence level (CL) and has a three-sigma observation potential of 8.7×1023 years, approaching the predictions of nuclear models. For the neutrinoless decay mode LZ, is projected to exclude values of the half-life up to 7.3×1024 years at 90% CL
Cosmogenic production of {37}^Ar in the context of the LUX-ZEPLIN experiment
We estimate the amount of {37}^Ar produced in natural xenon via cosmic-ray-induced spallation, an inevitable consequence of the transportation and storage of xenon on the Earth’s surface. We then calculate the resulting {37}^Ar concentration in a 10-tonne payload (similar to that of the LUX-ZEPLIN experiment) assuming a representative schedule of xenon purification, storage, and delivery to the underground facility. Using the spallation model by Silberberg and Tsao, the sea-level production rate of {37}^Ar in natural xenon is estimated to be 0.024 atoms/kg/day. Assuming the xenon is successively purified to remove radioactive contaminants in 1-tonne batches at a rate of 1 tonne/month, the average {37}^Ar activity after 10 tons are purified and transported underground is 0.058 - 0.090 μ Bq/kg, depending on the degree of argon removal during above-ground purification. Such cosmogenic {37}^Ar will appear as a noticeable background in the early science data, while decaying with a 35-day half-life. This newly noticed production mechanism of {37}^Ar should be considered when planning for future liquid-xenon-based experiments
First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment
The LUX-ZEPLIN experiment is a dark matter detector centered on a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility in Lead, South Dakota, USA. This Letter reports results from LUX-ZEPLIN's first search for weakly interacting massive particles (WIMPs) with an exposure of 60 live days using a fiducial mass of 5.5 t. A profile-likelihood ratio analysis shows the data to be consistent with a background-only hypothesis, setting new limits on spin-independent WIMP-nucleon, spin-dependent WIMP-neutron, and spin-dependent WIMP-proton cross sections for WIMP masses above 9 GeV/c2. The most stringent limit is set for spin-independent scattering at 36 GeV/c2, rejecting cross sections above 9.2×10-48 cm at the 90% confidence level
Background Determination for the LUX-ZEPLIN (LZ) Dark Matter Experiment
The LUX-ZEPLIN experiment recently reported limits on WIMP-nucleus
interactions from its initial science run, down to cm
for the spin-independent interaction of a 36 GeV/c WIMP at 90% confidence
level. In this paper, we present a comprehensive analysis of the backgrounds
important for this result and for other upcoming physics analyses, including
neutrinoless double-beta decay searches and effective field theory
interpretations of LUX-ZEPLIN data. We confirm that the in-situ determinations
of bulk and fixed radioactive backgrounds are consistent with expectations from
the ex-situ assays. The observed background rate after WIMP search criteria
were applied was events/keV/kg/day in the
low-energy region, approximately 60 times lower than the equivalent rate
reported by the LUX experiment.Comment: 25 pages, 15 figure
A search for new physics in low-energy electron recoils from the first LZ exposure
The LUX-ZEPLIN (LZ) experiment is a dark matter detector centered on a
dual-phase xenon time projection chamber. We report searches for new physics
appearing through few-keV-scale electron recoils, using the experiment's first
exposure of 60 live days and a fiducial mass of 5.5t. The data are found to be
consistent with a background-only hypothesis, and limits are set on models for
new physics including solar axion electron coupling, solar neutrino magnetic
moment and millicharge, and electron couplings to galactic axion-like particles
and hidden photons. Similar limits are set on weakly interacting massive
particle (WIMP) dark matter producing signals through ionized atomic states
from the Migdal effect.Comment: 13 pages, 10 figures. See https://tinyurl.com/LZDataReleaseRun1ER for
a data release related to this pape
Projected sensitivities of the LUX-ZEPLIN experiment to new physics via low-energy electron recoils
LUX-ZEPLIN is a dark matter detector expected to obtain world-leading sensitivity to weakly-interacting massive particles interacting via nuclear recoils with a
∼
7
-tonne xenon target mass. This paper presents sensitivity projections to several low-energy signals of the complementary electron recoil signal type: 1) an effective neutrino magnetic moment, and 2) an effective neutrino millicharge, both for
p
p
-chain solar neutrinos, 3) an axion flux generated by the Sun, 4) axionlike particles forming the Galactic dark matter, 5) hidden photons, 6) mirror dark matter, and 7) leptophilic dark matter. World-leading sensitivities are expected in each case, a result of the large 5.6 t 1000 d exposure and low expected rate of electron-recoil backgrounds in the
<
100
keV
energy regime. A consistent signal generation, background model and profile-likelihood analysis framework is used throughout
First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment
The LUX-ZEPLIN (LZ) experiment is a dark matter detector centered on a
dual-phase xenon time projection chamber operating at the Sanford Underground
Research Facility in Lead, South Dakota, USA. This Letter reports results from
LZ's first search for Weakly Interacting Massive Particles (WIMPs) with an
exposure of 60 live days using a fiducial mass of 5.5 t. A profile-likelihood
ratio analysis shows the data to be consistent with a background-only
hypothesis, setting new limits on spin-independent WIMP-nucleon, spin-dependent
WIMP-neutron, and spin-dependent WIMP-proton cross-sections for WIMP masses
above 9 GeV/c. The most stringent limit is set at 30 GeV/c, excluding
cross sections above 5.9 cm at the 90\% confidence level.Comment: 9 pages, 6 figures. See https://tinyurl.com/LZDataReleaseRun1 for a
data release related to this pape
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
The nature of dark matter and properties of neutrinos are among the mostpressing issues in contemporary particle physics. The dual-phase xenontime-projection chamber is the leading technology to cover the availableparameter space for Weakly Interacting Massive Particles (WIMPs), whilefeaturing extensive sensitivity to many alternative dark matter candidates.These detectors can also study neutrinos through neutrinoless double-beta decayand through a variety of astrophysical sources. A next-generation xenon-baseddetector will therefore be a true multi-purpose observatory to significantlyadvance particle physics, nuclear physics, astrophysics, solar physics, andcosmology. This review article presents the science cases for such a detector.<br
- …