478 research outputs found

    The subcoronary Toronto stentless versus supra-annular Perimount stented replacement aortic valve: Early clinical and hemodynamic results of a randomized comparison in 160 patients

    Get PDF
    BackgroundA stentless valve is expected to be hemodynamically superior to a stented valve. The aim of this study was to compare early postoperative hemodynamic function and clinical events in a randomized, prospective series of 160 stentless and stented biological replacement aortic valves.MethodsWe randomized 160 consecutive patients on 1 surgeon’s list to receive either a Toronto stentless porcine valve (St Jude Medical, Inc, St Paul, Minn) or a Perimount stented bovine pericardial valve (Edwards Lifesciences, Irvine, Calif). Echocardiography was performed at discharge, between 3 and 6 months, and at 1 year after surgery. Statistical analysis was performed by both intention to treat and actual valves implanted.ResultsThe mean labeled size of both designs of valve was 24.7. There were no statistically significant differences in results at any time interval or whether analysis was performed by actual valves implanted or intention to treat. At 3 to 6 months for the Toronto versus the Perimount valve, the effective orifice area was 1.58 versus 1.66 cm2, the mean pressure difference was 7.54 versus 7.42 mm Hg, and the peak velocity was 2.07 versus 2.0.1 m/s. There was no difference in mortality, regression of left ventricular hypertrophy, or complications other than paraprosthetic regurgitation at 12 months or on follow-up for a proportion of the sample to 8 years. The incidence of regurgitation through the valves was similar for Toronto (10%) and Perimount (13.8%) at 1 year, but mild paraprosthetic regurgitation was found in 5 patients with the Perimount valve and none with Toronto valves.ConclusionsThere were no significant differences in hemodynamic function or clinical events between the stented and stentless biological valves chosen for comparison in the early postoperative period or in preliminary follow-up to 5 years

    Histomorphometric Assessment of Cancellous and Cortical Bone Material Distribution in the Proximal Humerus of Normal and Osteoporotic Individuals Significantly Reduced Bone Stock in the Metaphyseal and Subcapital Regions of Osteoporotic Individuals

    Get PDF
    Osteoporosis is a systemic disorder predominantly affecting postmenopausal women but also men at an advanced age. Both genders may suffer from low-energy fractures of, for example, the proximal humerus when reduction of the bone stock or/and quality has occurred. The aim of the current study was to compare the amount of bone in typical fracture zones of the proximal humerus in osteoporotic and non-osteoporotic individuals. The amount of bone in the proximal humerus was determined histomorphometrically in frontal plane sections. The donor bones were allocated to normal and osteoporotic groups using the T-score from distal radius DXA measurements of the same extremities. The T-score evaluation was done according to WHO criteria. Regional thickness of the subchondral plate and the metaphyseal cortical bone were measured using interactive image analysis. At all measured locations the amount of cancellous bone was significantly lower in individuals from the osteoporotic group compared to the non-osteoporotic one. The osteoporotic group showed more significant differences between regions of the same bone than the non-osteoporotic group. In both groups the subchondral cancellous bone and the subchondral plate were least affected by bone loss. In contrast, the medial metaphyseal region in the osteoporotic group exhibited higher bone loss in comparison to the lateral side. This observation may explain prevailing fracture patterns, which frequently involve compression fractures and certainly has an influence on the stability of implants placed in this medial region. It should be considered when planning the anchoring of osteosynthesis materials in osteoporotic patients with fractures of the proximal humerus

    Control of starch branching in barley defined through differential RNAi suppression of starch branching enzyme IIa and IIb

    Get PDF
    The roles of starch branching enzyme (SBE, EC 2.4.1.18) IIa and SBE IIb in defining the structure of amylose and amylopectin in barley (Hordeum vulgare) endosperm were examined. Barley lines with low expression of SBE IIa or SBE IIb, and with the low expression of both isoforms were generated through RNA-mediated silencing technology. These lines enabled the study of the role of each of these isoforms in determining the amylose content, the distribution of chain lengths, and the frequency of branching in both amylose and amylopectin. In lines where both SBE IIa and SBE IIb expression were reduced by >80%, a high amylose phenotype (>70%) was observed, while a reduction in the expression of either of these isoforms alone had minor impact on amylose content. The structure and properties of the high amylose starch resulting from the concomitant reduction in the expression of both isoforms of SBE II in barley were found to approximate changes seen in amylose extender mutants of maize, which result from lesions eliminating expression of the SBE IIb gene. Amylopectin chain length distribution analysis indicated that both SBE IIa and SBE IIb isoforms play distinct roles in determining the fine structure of amylopectin. A significant reduction in the frequency of branches in amylopectin was noticed only when both SBE IIa and SBE IIb were reduced, whereas there was a significant increase in the branching frequency of amylose when SBE IIb alone was reduced. Functional interactions between SBE isoforms are suggested, and a possible inhibitory role of SBE IIb on other SBE isoforms is discussed

    Long‑term results of the augmented PFNA: a prospective multicenter trial

    Get PDF
    Producción CientíficaPertrochanteric fractures are increasing and their operative treatment remains under discussion. Failures needing reoperations such as a cut-out are reported to be high and are associated with multiple factors including poor bone quality, poor fracture reduction and improper implant placement. The PFNA® with perforated blade offers an option for standardized cement augmentation with a PMMA cement to provide more stability to the fracture fixation. It remains unclear if the augmentation of this implant does any harm in a longer time span. This prospective multicenter study shows clinical and radiological results with this implant with a mean follow-up time of 15 months

    Standardised cement augmentation of the PFNA using a perforated blade: A new technique and preliminary clinical results. A prospective multicentre trial

    Get PDF
    Producción CientíficaPertrochanteric fractures are a rising major health-care problem in the elderly and their operative stabilisation techniques are still under discussion. Furthermore, complications like cut-out are reported to be high and implant failure often is associated with poor bone quality. The PFNA1 with perforated blade offers a possibility for standardised cement augmentation using a polymethylmethacrylate (PMMA) cement which is injected through the perforated blade to enlarge the load-bearing surface and to diminish the stresses on the trabecular bone. The current prospective multicentre study was undertaken to evaluate the technical performance and the early clinical results of this new device. In nine European clinics, 59 patients (45 female, mean age 84.5 years) suffering from an osteoporotic pertrochanteric fracture (Arbeitsgemeinschaft fu¨ r Osteosynthesefragen, AO-31) were treated with the augmented PFNA1. Primary objectives were assessment of operative and postoperative complications, whereas activities of daily living, pain, mobility and radiologic parameters, such as cement distribution around the blade and the cortical thickness index, were secondary objectives. The mean follow-up time was 4 months where we observed callus healing in all cases. The surgical complication rate was 3.4% with no complication related to the cement augmentation. More than onehalf of the patients reached their prefracture mobility level within the study period. A mean volume of 4.2 ml of cement was injected. We did not find any cut-out, cut through, unexpected blade migration, implant loosening or implant breakage within the study period. Our findings lead us to conclude that the standardised cement augmentation using the perforated blade for pertrochanteric fracture fixation enhances the implant anchorage within the head–neck fragment and leads to good functional results

    Differences in cortical contractile properties between healthy epithelial and cancerous mesenchymal breast cells

    Get PDF
    Cell contractility is mainly imagined as a force dipole-like interaction based on actin stress fibers that pull on cellular adhesion sites. Here, we present a different type of contractility based on isotropic contractions within the actomyosin cortex. Measuring mechanosensitive cortical contractility of suspended cells among various cell lines allowed us to exclude effects caused by stress fibers. We found that epithelial cells display a higher cortical tension than mesenchymal cells, directly contrasting to stress fiber-mediated contractility. These two types of contractility can even be used to distinguish epithelial from mesenchymal cells. These findings from a single cell level correlate to the rearrangement effects of actomyosin cortices within cells assembled in multicellular aggregates. Epithelial cells form a collective contractile actin cortex surrounding multicellular aggregates and further generate a high surface tension reminiscent of tissue boundaries. Hence, we suggest this intercellular structure as to be crucial for epithelial tissue integrity. In contrast, mesenchymal cells do not form collective actomyosin cortices reducing multicellular cohesion and enabling cell escape from the aggregates
    corecore