10,190 research outputs found

    Fast analytical methods for the correction of signal random time-shifts and application to segmented HPGe detectors

    Full text link
    Detection systems rely more and more on on-line or off-line comparison of detected signals with basis signals in order to determine the characteristics of the impinging particles. Unfortunately, these comparisons are very sensitive to the random time shifts that may alter the signal delivered by the detectors. We present two fast algebraic methods to determine the value of the time shift and to enhance the reliability of the comparison to the basis signals.Comment: 13 pages, 8 figure

    Kolmogorov-Smirnov method for the determination of signal time-shifts

    Full text link
    A new method for the determination of electric signal time-shifts is introduced. As the Kolmogorov-Smirnov test, it is based on the comparison of the cumulative distribution functions of the reference signal with the test signal. This method is very fast and thus well suited for on-line applications. It is robust to noise and its performances in terms of precision are excellent for time-shifts ranging from a fraction to several sample durations. PACS. 29.40.Gx (Tracking and position-sensitive detectors), 29.30.Kv (X- and -ray spectroscopy), 07.50.Qx (Signal processing electronics)Comment: 8 pages, 7 figure

    Creep motion of a model frictional system

    Get PDF
    We report on the dynamics of a model frictional system submitted to minute external perturbations. The system consists of a chain of sliders connected through elastic springs that rest on an incline. By introducing cyclic expansions and contractions of the springs we observe a reptation of the chain. We account for the average reptation velocity theoretically. The velocity of small systems exhibits a series of plateaus as a function of the incline angle. Due to elastic e ects, there exists a critical amplitude below which the reptation is expected to cease. However, rather than a full stop of the creep, we observe in numerical simulations a transition between a continuous-creep and an irregular-creep regime when the critical amplitude is approached. The latter transition is reminiscent of the transition between the continuous and the irregular compaction of granular matter submitted to periodic temperature changes

    An international prospective general population-based study of respiratory work disability

    Get PDF
    Background: Previous cross-sectional studies have shown that job change due to breathing problems at the workplace (respiratory work disability) is common among adults of working age. That research indicated that occupational exposure to gases, dust and fumes was associated with job change due to breathing problems, although causal inferences have been tempered by the cross-sectional nature of previously available data. There is a need for general population-based prospective studies to assess the incidence of respiratory work disability and to delineate better the roles of potential predictors of respiratory work disability.Methods: A prospective general population cohort study was performed in 25 centres in 11 European countries and one centre in the USA. A longitudinal analysis was undertaken of the European Community Respiratory Health Survey including all participants employed at any point since the baseline survey, 6659 subjects randomly sampled and 779 subjects comprising all subjects reporting physician-diagnosed asthma. The main outcome measure was new-onset respiratory work disability, defined as a reported job change during follow-up attributed to breathing problems. Exposure to dusts (biological or mineral), gases or fumes during follow-up was recorded using a job-exposure matrix. Cox proportional hazard regression modelling was used to analyse such exposure as a predictor of time until job change due to breathing problems.Results: The incidence rate of respiratory work disability was 1.2/1000 person-years of observation in the random sample (95% CI 1.0 to 1.5) and 5.7/1000 person-years in the asthma cohort (95% CI 4.1 to 7.8). In the random population sample, as well as in the asthma cohort, high occupational exposure to biological dust, mineral dust or gases or fumes predicted increased risk of respiratory work disability. In the random sample, sex was not associated with increased risk of work disability while, in the asthma cohort, female sex was associated with an increased disability risk (hazard ratio 2.8, 95% CI 1.3 to 5.9).Conclusions: Respiratory work disability is common overall. It is associated with workplace exposures that could be controlled through preventive measures

    STM Imaging of Flux Line Arrangements in the Peak Effect Regime

    Get PDF
    We present the results of a study of vortex arrangements in the peak-effect regime of 2H-NbSe_2 by scanning tunneling microscopy. By slowly increasing the temperature in a constant magnetic field, we observed a sharp transition from collective vortex motion to positional fluctuations of individual vortices at the temperature which coincides with the onset of the peak effect in ac-susceptibility. We conclude that the peak effect is a disorder driven transition, with the pinning energy winning from the elastic energy.Comment: 4 pages, 4 figures included Manuscript has been submitte

    Human pulmonary responses to experimental inhalation of high concentration fine and ultrafine magnesium oxide particles.

    Get PDF
    Exposure to air polluted with particles less than 2.5 micron in size is associated epidemiologically with adverse cardiopulmonary health consequences in humans. The goal of this study was to characterize human pulmonary responses to controlled experimental high-dose exposure to fine and ultrafine magnesium oxide particles. We quantified bronchoalveolar lavage (BAL) cell and cytokine concentrations, pulmonary function, and peripheral blood neutrophil concentrations in six healthy volunteers 18 to 20 hr after inhalation of fine and ultrafine magnesium oxide particles produced from a furnace system model. We compared postexposure studies with control studies from the same six subjects. Mean +/- standard deviation (SD) cumulative magnesium dose was 4,138 +/- 2,163 min x mg/m3. By weight, 28% of fume particles were ultrafine (<0.1 micron in diameter) and over 98% of fume particles were fine (<2.5 micron in diameter). There were no significant differences in BAL inflammatory cell concentrations, BAL interleukin (IL)-1, IL-6, IL-8, tumor necrosis factor, pulmonary function, or peripheral blood neutrophil concentrations postexposure compared with control. Our findings suggest that high-dose fine and ultrafine magnesium oxide particle exposure does not produce a measurable pulmonary inflammatory response. These findings are in marked contrast with the well-described pulmonary inflammatory response following zinc oxide particle inhalation. We conclude that fine and ultrafine particle inhalation does not result in toxicity in a generic manner independent of particle composition. Our findings support the concept that particle chemical composition, in addition to particle size, is an important determinant of respiratory effects

    First Investigations of In Situ Electrical Properties of Limestone Blocks of Ancient Monuments

    Get PDF
    International audienceIn situ rapid electrostatic investigations on calcareous stones of monuments provide information that strongly correlates with the geological characteristics of the stone and proves to be efficient for provenance identification and successive restoration. With a portable device, it is now possible to scan several thousand blocks on a face of a monument in a few hours. The evolution of the religious building construction practices between the 13th and the 17th centuries is studied. From the petrophysics point of view, the results clearly indicate a marked linear correlation between electrical conductivity and dielectric permittivity. This fact, which agrees with Maxwell–Wagner polarization modelling, confirms the part played by the clay content in the electric properties of the dry carbonate rocks constituting the monument stones. A first test using X-ray scattering analysis shows the part played by the relative content of illite, which is correlated with a decrease of the resistivity

    Primordial and primary prevention of peri-implant diseases: A systematic review and meta-analysis

    Get PDF
    Aim: This systematic review and meta-analysis aims to assess the efficacy of risk factor control to prevent the occurrence of peri-implant diseases (PIDs) in adult patients awaiting dental implant rehabilitation (primordial prevention) or in patients with dental implants surrounded by healthy peri-implant tissues (primary prevention). Materials and Methods: A literature search was performed without any time limit on different databases up to August 2022. Interventional and observational studies with at least 6&nbsp;months of follow-up were considered. The occurrence of peri-implant mucositis and/or peri-implantitis was the primary outcome. Pooled data analyses were performed using random effect models according to the type of risk factor and outcome. Results: Overall, 48 studies were selected. None assessed the efficacy of primordial preventive interventions for PIDs. Indirect evidence on the primary prevention of PID indicated that diabetic patients with dental implants and good glycaemic control have a significantly lower risk of peri-implantitis (odds ratio [OR]&nbsp;=&nbsp;0.16; 95% confidence interval [CI]: 0.03–0.96; I2: 0%), and lower marginal bone level (MBL) changes (OR&nbsp;=&nbsp;–0.36 mm; 95% CI: −0.65 to −0.07; I2: 95%) compared to diabetic patients with poor glycaemic control. Patients attending supportive periodontal/peri-implant care (SPC) regularly have a lower risk of overall PIDs (OR&nbsp;=&nbsp;0.42; 95% CI: 0.24–0.75; I2: 57%) and peri-implantitis compared to irregular attendees. The risk of dental implant failure (OR&nbsp;=&nbsp;3.76; 95% CI: 1.50–9.45; I2: 0%) appears to be greater under irregular or no SPC than regular SPC. Implants sites with augmented peri-implant keratinized mucosa (PIKM) show lower peri-implant inflammation (SMD&nbsp;=&nbsp;–1.18; 95% CI: −1.85 to −0.51; I2: 69%) and lower MBL changes (MD&nbsp;=&nbsp;–0.25; 95% CI: −0.45 to −0.05; I2: 62%) compared to dental implants with PIKM deficiency. Studies on smoking cessation and oral hygiene behaviors were inconclusive. Conclusions: Within the limitations of available evidence, the present findings indicate that in patients with diabetes, glycaemic control should be promoted to avoid peri-implantitis development. The primary prevention of peri-implantitis should involve regular SPC. PIKM augmentation procedures, where a PIKM deficiency exists, may favour the control of peri-implant inflammation and the stability of MBL. Further studies are needed to assess the impact of smoking cessation and oral hygiene behaviours, as well as the implementation of standardized primordial and primary prevention protocols for PIDs
    • …
    corecore