675 research outputs found

    Assessing the material loss of the modular taper interface in retrieved metal on metal hip replacements

    Get PDF
    Measuring the amount of material loss in the case of revised hip replacements is considered to be a prerequisite of understanding and assessing the true in vivo performance of the implant. This paper outlines a method developed by the authors for quantifying taper material loss as well as more general taper interface parameters. Previous studies have mostly relied on visual inspection to assess the material loss at the taper interface, whereas this method aims to characterize any surface and form changes through the use of an out-of-roundness measurement machine. Along with assessing the volumetric wear, maximum linear penetration and taper contact length can also be determined. The method was applied to retrieved large head metal-on-metal femoral heads in order to quantify the material loss at this junction. Material loss from the female femoral head taper can be characterized as a localized area that is in contact with the stem taper surface. The study showed that this method has good repeatability and a low level of interoperability variation between operators

    Agricultural Districts: Lessons from New York

    Full text link

    What is required to measure the wear of explanted metal on metal hips?

    Get PDF
    Abstract INTRODUCTION There is increasing worldwide interest in the assessment of wear in explanted hip components. This is due is part to high profile failures of orthopaedic components in the US, whilst in the UK hip resurfacings have been experiencing a higher than expected failure rate. The reasons for these failures are not well understood, with data from the NJR suggesting the 43% of MoM resurfacing failures are unexplained. Wear analysis is a vital tool in determining failure mechanisms and ultimately improving the longevity of joint replacements through improved design and manufacturing control. There are currently no relevant measurement standards for the evaluation of retrieved orthopaedic components. This paper will assess two of the most commonly used techniques namely roundness measurement and co-ordinate measurement. The advantages and disadvantages of both techniques are considered in this paper. ROUNDNESS MACHINE The Talyrond 365 is a stylus based roundness machine. The component is located on a rotating table and the stylus measures the deviation from a perfect circle as the component is slowly rotated. The Talyrond measures a single profile to an accuracy of 30 nm and up to 72,000 data points per revolution. The air spindle has a radial accuracy of <0.02 μm and the Talymin gauge a minimum resolution of 12 nm. Individual roundness profiles can be stitched together to build up 3D cylinder maps, allowing 3D pictures of sections of explanted hip components to be generated. COORDINATE MEASURING MACHINE Co-ordinate measuring machines (CMMs) have been widely used in manufacturing quality and research departments for a number of years and the CMM is recognised as a powerful and important tool capable of ascertaining geometric data from a component. The CMM used in this study was a Zeiss Prismo CMM (Carl Zeiss Ltd., Rugby, UK) with a probing error of 0.7 μm. Components are securely held in a chuck fixture arrangement and the dimensions of the component in the portion of the bearing that is unworn is ascertained through measurement. The initial measurements are used to produce a reverse engineered 3D CAD surface which represents the component ‘pre-wear’ surface. The surface of the component is then scanned and the deviation from this pre-wear surface is mapped. The maximum linear wear and wear volume are then calculated directly. DISCUSSION The main advantage of CMM and Talyrond is that they are available in most metrology and measurement rooms. The CMM is a particularly versatile machine and can be used to measure any orthopaedic components. There is a need to develop a suitable Standard for both machines detailing a protocol to measure explanted hip and quantify the wear. A study is underway to measure a set of explanted hip components to allow a detailed comparison between of measurements between the Talyrond and CMM. The result of this study will be included in the paper. CONCLUSIONS The CMM and Talyrond are both instruments suited to measuring wear of explanted hips. A full evaluation of the systems and the development of robust measurement protocol and standard would be advantageous to the orthopaedic industry

    Using Geological Implications of a Physical Libration to Constrain Enceladus' Libration State

    Get PDF
    Observations of Enceladus' south pole revealed large rifts in the crust, called "tiger stripes", which exhibit higher temperatures than the surrounding terrain and are likely sources of observed eruptions. Tidal stress may periodically open the tiger stripe rifts, controlling the timing and location of eruptions. Moreover, shear motion along rifts may produce the heat to drive eruptions

    Geological Implications of a Physical Libration on Enceladus

    Get PDF
    Given the non-spherical shape of Enceladus (Thomas et al., 2007), the satellite will experience gravitational torques that will cause it to physically librate as it orbits Saturn. Physical libration would produce a diurnal oscillation in the longitude of Enceladus tidal bulge which, could have a profound effect on the diurnal stresses experienced by the surface of the satellite. Although Cassini ISS has placed an observational upper limit on Enceladus libration amplitude of F < 1.5deg (Porco et al., 2006), smaller amplitudes can still have geologically significant consequences. Here we present the first detailed description of how physical libration affects tidal stresses and how those stresses then might affect geological processes including crack formation and propagation, south polar eruption activity, and tidal heating. Our goal is to provide a framework for testing the hypothesis that geologic features on Enceladus are produced by tidal stresses from diurnal physical and optical librations of the satellite

    The influence of hydroalcoholic media on the performance of Grewia polysaccharide in sustained release tablets

    Get PDF
    Co-administration of drugs with alcohol can affect the plasma concentration of drugs in patients. It is also known that the excipients used in the formulation of drugs may not always be resistant to alcohol. This study evaluates effect of varying alcohol concentrations on theophylline release from two grades of Grewia mollis polysaccharides. X-ray microtomography showed that native polysaccharide formulation compacts were not homogenous after the mixing process resulting in its failure in swelling studies. Removal of starch from the native polysaccharide resulted in homogenous formulation compacts resistant to damage in high alcoholic media in pH 6.8 (40%v/v absolute ethanol). Destarched polymer compacts had a significantly higher hardness (375 N) than that of the native polysaccharide (82 N) and HPMC K4 M (146 N). Dissolution studies showed similarity at all levels of alcohol tested (f2 = 57-91) in simulated gastric media (pH 1.2). The dissolution profiles in the simulated intestinal fluids were also similar (f2 = 60-94), with the exception of the native polysaccharide in pH 6.8 (40%v/v absolute ethanol) (f2 = 43). This work highlights the properties of Grewia polysaccharide as a matrix former that can resist high alcoholic effects therefore; it may be suitable as an alternative to some of the commercially available matrix formers with wider applications for drug delivery as a cheaper alternative in the developing world

    Development of an in vitro cell system from zebrafish suitable to study bone cell differentiation and extracellular matrix mineralization

    Get PDF
    Mechanisms of bone formation and skeletal development have been successfully investigated in zebrafish using a variety of in vivo approaches, but in vitro studies have been hindered due to a lack of homologous cell lines capable of producing an extracellular matrix (ECM) suitable for mineral deposition. Here we describe the development and characterization of a new cell line termed ZFB1, derived from zebrafish calcified tissues. ZFB1 cells have an epithelium-like phenotype, grow at 28 degrees C in a regular L-15 medium supplemented with 15% of fetal bovine serum, and are maintained and manipulated using standard methods (e.g., trypsinization, cryopreservation, and transfection). They can therefore be propagated and maintained easily in most cell culture facilities. ZFB1 cells show aneuploidy with 2n=78 chromosomes, indicative of cell transformation. Furthermore, because DNA can be efficiently delivered into their intracellular space by nucleofection, ZFB1 cells are suitable for gene targeting approaches and for assessing gene promoter activity. ZFB1 cells can also differentiate toward osteoblast or chondroblast lineages, as demonstrated by expression of osteoblast- and chondrocyte-specific markers, they exhibit an alkaline phosphatase activity, a marker of bone formation in vivo, and they can mineralize their ECM. Therefore, they represent a valuable zebrafish-derived in vitro system for investigating bone cell differentiation and extracellular matrix mineralization.FISHCELL project [PTDC/MAR/105313/2008]; Portuguese Science and Technology Foundation (FCT); European Regional Development Fund (ERDF) through the COMPETE Program; National Fund through FCT [PEst-C/MAR/LA0015/2011]; FCT [SFRH/BPD/39189/2007]; Association of European Marine Biological Laboratories through the ASSEMBLE project [FP7/227799]info:eu-repo/semantics/publishedVersio
    corecore