22 research outputs found

    Diagnostics to Support Elimination of Lymphatic Filariasis-Development of Two Target Product Profiles

    Get PDF
    As lymphatic filariasis (LF) programs move closer to established targets for validation elimination of LF as a public health problem, diagnostic tools capable of supporting the needs of the programs are critical for success. Known limitations of existing diagnostic tools make it challenging to have confidence that program endpoints have been achieved. In 2019, the World Health Organization (WHO) established a Diagnostic Technical Advisory Group (DTAG) for Neglected Tropical Diseases tasked with prioritizing diagnostic needs including defining use-cases and target product profiles (TPPs) for needed tools. Subsequently, disease-specific DTAG subgroups, including one focused on LF, were established to develop TPPs and use-case analyses to be used by product developers. Here, we describe the development of two priority TPPs for LF diagnostics needed for making decisions for stopping mass drug administration (MDA) of a triple drug regimen and surveillance. Utilizing the WHO core TPP development process as the framework, the LF subgroup convened to discuss and determine attributes required for each use case. TPPs considered the following parameters: Product use, design, performance, product configuration and cost, and access and equity. Version 1.0 TPPs for two use cases were published by WHO on 12 March 2021 within the WHO Global Observatory on Health Research and Development. A common TPP characteristic that emerged in both use cases was the need to identify new biomarkers that would allow for greater precision in program delivery. As LF diagnostic tests are rarely used for individual clinical diagnosis, it became apparent that reliance on population-based surveys for decision making requires consideration of test performance in the context of such surveys. In low prevalence settings, the number of false positive test results may lead to unnecessary continuation or resumption of MDA, thus wasting valuable resources and time. Therefore, highly specific diagnostic tools are paramount when used to measure low thresholds. The TPP process brought to the forefront the importance of linking use case, program platform and diagnostic performance characteristics when defining required criteria for diagnostic tools

    Diagnostics and the neglected tropical diseases roadmap: setting the agenda for 2030.

    Get PDF
    Accurate and reliable diagnostic tools are an essential requirement for neglected tropical diseases (NTDs) programmes. However, the NTD community has historically underinvested in the development and improvement of diagnostic tools, potentially undermining the successes achieved over the last 2 decades. Recognizing this, the WHO, in its newly released draft roadmap for NTD 2021-2030, has identified diagnostics as one of four priority areas requiring concerted action to reach the 2030 targets. As a result, WHO established a Diagnostics Technical Advisory Group (DTAG) to serve as the collaborative mechanism to drive progress in this area. Here, the purpose and role of the DTAG are described in the context of the challenges facing NTD programmes

    Realistically, how far are we from a universal malaria drug?

    No full text

    S9.6-based hybrid capture immunoassay for pathogen detection

    No full text
    Abstract The detection of pathogens is critical for clinical diagnosis and public health surveillance. Detection is usually done with nucleic acid-based tests (NATs) and rapid antigen tests (e.g., lateral flow assays [LFAs]). Although NATs are more sensitive and specific, their use is often limited in resource-poor settings due to specialized requirements. To address this limitation, we developed a rapid DNA-RNA Hybrid Capture immunoassay (HC) that specifically detects RNA from pathogens. This assay utilizes a unique monoclonal antibody, S9.6, which binds DNA-RNA hybrids. Biotinylated single-stranded DNA probes are hybridized to target RNAs, followed by hybrid capture on streptavidin and detection with S9.6. The HC-ELISA assay can detect as few as 104 RNA molecules that are 2.2 kb in length. We also adapted this assay into a LFA format, where captured Bacillus anthracis rpoB RNA of 3.5 kb length was detectable from a bacterial load equivalent to 107 CFU per 100 mg of mouse tissue using either HC-ELISA or HC-LFA. Importantly, we also demonstrated the versatility of HC by detecting other pathogens, including SARS-CoV-2 and Toxoplasma gondii, showing its potential for broad pathogen detection. Notably, HC does not require amplification of the target nucleic acid and utilizes economical formats like ELISA and LFA, making it suitable for use in sentinel labs for pathogen detection or as a molecular tool in basic research laboratories. Our study highlights the potential of HC as a sensitive and versatile method for RNA-based pathogen detection

    Proof-of-Concept Rapid Diagnostic Test for Onchocerciasis: Exploring Peptide Biomarkers and the Use of Gold Nanoshells as Reporter Nanoparticles

    No full text
    Three <i>O. volvulus</i> immunogenic peptide sequences recently discovered by peptide microarray were adapted to a lateral flow assay (LFA). The LFA employs gold nanoshells as novel high-contrast reporter nanoparticles and detects a serological response against the 3 peptides, found in OvOC9384, OvOC198, and OvOC5528, respectively. When tested on 118 sera from <i>O. volvulus</i> infected patients and 208 control sera, the LFA was 90%, 63%, and 98% sensitive for each peptide, respectively, and 99–100% specific vs samples from healthy volunteers. Samples of other filarial infections cross-reacted by 7–24%. The sensitivity, specificity, and cross-reactivity values matched those obtained by ELISA with the same sample set. While the exact choice of peptide(s) will require fine-tuning, this work establishes that <i>O. volvulus</i> peptides identified by peptide microarray can be translated into an antibody-based LFA and that gold nanoshells provide the same sensitivity, specificity, and cross-reactivity as the corresponding ELISA assays

    A novel rapid test for detecting antibody responses to <i>Loa loa</i> infections

    No full text
    <div><p>Ivermectin-based mass drug administration (MDA) programs have achieved remarkable success towards the elimination of onchocerciasis and lymphatic filariasis. However, their full implementation has been hindered in Central Africa by the occurrence of ivermectin-related severe adverse events (SAEs) in a subset of individuals with high circulating levels of <i>Loa loa</i> microfilariae. Extending MDA to areas with coincident <i>L</i>. <i>loa</i> infection is problematic, and inexpensive point-of-care tests for <i>L</i>. <i>loa</i> are acutely needed. Herein, we present a lateral flow assay (LFA) to identify subjects with a serological response to <i>Ll</i>-SXP-1, a specific and validated marker of <i>L</i>. <i>loa</i>. The test was evaluated on serum samples from patients infected with <i>L</i>. <i>loa</i> (n = 109) and other helminths (n = 204), as well as on uninfected controls (n = 77). When read with the naked eye, the test was 94% sensitive for <i>L</i>. <i>loa</i> infection and was 100% specific when sera from healthy endemic and non-endemic controls or from those with <i>S</i>. <i>stercoralis</i> infections were used as the comparators. When sera of patients with <i>O</i>. <i>volvulus</i>, <i>W</i>. <i>bancrofti</i>, or <i>M</i>. <i>perstans</i> were used as the comparators, the specificity of the LFA was 82%, 87%, and 88%, respectively. A companion smartphone reader allowed measurement of the test line intensities and establishment of cutoff values. With a cutoff of 600 Units, the assay sensitivity decreased to 71%, but the specificity increased to 96% for <i>O</i>. <i>volvulus</i>, 100% for <i>W</i>. <i>bancrofti</i>, and 100% for <i>M</i>. <i>perstans</i>-infected individuals. The LFA may find applications in refining the current maps of <i>L</i>. <i>loa</i> prevalence, which are needed to eliminate onchocerciasis and lymphatic filariasis from the African continent.</p></div

    Epithelial-to-mesenchymal transition in FHC-silenced cells: the role of CXCR4/CXCL12 axis

    No full text
    Abstract Background Ferritin plays a central role in the intracellular iron metabolism; the molecule is a nanocage of 24 subunits of the heavy and light types. The heavy subunit (FHC) is provided of a ferroxidase activity and thus performs the key transformation of iron in a non-toxic form. Recently, it has been shown that FHC is also involved in additional not iron-related critical pathways including, among the others, p53 regulation, modulation of oncomiRNAs expression and chemokine signalling. Epithelial to mesenchymal transition (EMT) is a cellular mechanism by which the cell acquires a fibroblast-like phenotype along with a decreased adhesion and augmented motility. In this work we have focused our attention on the role of the FHC on EMT induction in the human cell lines MCF-7 and H460 to elucidate the underlying molecular mechanisms. Methods Targeted silencing of the FHC was performed by lentiviral-driven shRNA strategy. Reconstitution of the FHC gene product was obtained by full length FHC cDNA transfection with Lipofectamine 2000. MTT and cell count assays were used to evaluate cell viability and proliferation; cell migration capability was assayed by the wound-healing assay and transwell strategy. Quantification of the CXCR4 surface expression was performed by flow cytometry. Results Experimental data indicated that FHC-silenced MCF-7 and H460 cells (MCF-7shFHC, H460shFHC) acquire a mesenchymal phenotype, accompanied by a significant enhancement of their migratory and proliferative capacity. This shift is coupled to an increase in ROS production and by an activation of the CXCR4/CXCL12 signalling pathway. We present experimental data indicating that the cytosolic increase in ROS levels is responsible for the enhanced proliferation of FHC-silenced cells, while the higher migration rate is attributable to a dysregulation of the CXCR4/CXCL12 axis. Conclusions Our findings indicate that induction of EMT, increased migration and survival depend, in MCF-7 and H460 cells, on the release of FHC control on two pathways, namely the iron/ROS metabolism and CXCR4/CXCL12 axis. Besides constituting a further confirmation of the multifunctional nature of FHC, this data also suggest that the analysis of FHC amount/function might be an important additional tool to predict tumor aggressiveness

    Onchocerciasis: Target product profiles of in vitro diagnostics to support onchocerciasis elimination mapping and mass drug administration stopping decisions

    Get PDF
    In June 2021, the World Health Organization (WHO), recognizing the need for new diagnostics to support the control and elimination of onchocerciasis, published the target product profiles (TPPs) of new tests that would support the two most immediate needs: (a) mapping onchocerciasis in areas of low prevalence and (b) deciding when to stop mass drug administration programs. In both instances, the test should ideally detect an antigen specific for live, adult O. volvulus female worms. The preferred format is a field-deployable rapid test. For mapping, the test needs to be ≥ 60% sensitive and ≥ 99.8% specific, while to support stopping decisions, the test must be ≥ 89% sensitive and ≥ 99.8% specific. The requirement for extremely high specificity is dictated by the need to detect with sufficient statistical confidence the low seroprevalence threshold set by WHO. Surveys designed to detect a 1-2% prevalence of a given biomarker, as is the case here, cannot tolerate more than 0.2% of false-positives. Otherwise, the background noise would drown out the signal. It is recognized that reaching and demonstrating such a stringent specificity criterion will be challenging, but test developers can expect to be assisted by national governments and implementing partners for adequately powered field validation

    Reproducibility of the smartphone reader.

    No full text
    <p>Pooled <i>L</i>. <i>loa</i> sera were tested at different dilutions on a given cassette, and the test line intensity was measured 25 consecutive times. The table reports the mean value and standard deviation in reader units, and coefficient of variation in %. Calculating a CV on negative serum is not meaningful since the denominator is close to zero.</p
    corecore