326 research outputs found

    Exploring root rot pathogens in wheat-pea rotations in Kansas

    Get PDF
    In 2018, over 277,000 bushels of wheat were produced on 7.7 million acres of land in Kansas alone. Based on the price of wheat by the end of 2018, this accounted for $1.44 million. This wheat is normally rotated with soybeans or fallow, but recent interest has arisen regarding the growth of peas in northern Kansas. As of 2019, there are both research and commercial growing operations underway. Many plant diseases have been especially prevalent during the summer because of the high rainfall and heat. In order to assess the severity of pea disease in Kansas, as well as explore potential interconnectivity between wheat and pea pathogens, a survey was conducted, and efforts were made to isolate and culture fungal pathogens of both wheat and pea

    Demonstration of a Thermally Coupled Row-Column SNSPD Imaging Array

    Get PDF
    While single-pixel superconducting nanowire single photon detectors (SNSPDs) have demonstrated remarkable efficiency and timing performance from the UV to near-IR, scaling these devices to large imaging arrays remains challenging. Here, we propose a new SNSPD multiplexing system using thermal coupling and detection correlations between two photosensitive layers of an array. Using this architecture with the channels of one layer oriented in rows and the second layer in columns, we demonstrate imaging capability in 16-pixel arrays with accurate spot tracking at the few-photon level. We also explore the performance trade-offs of orienting the top layer nanowires parallel and perpendicular to the bottom layer. The thermally coupled row-column scheme is readily able to scale to the kilopixel size with existing readout systems and, when combined with other multiplexing architectures, has the potential to enable megapixel scale SNSPD imaging arrays

    Demonstration of a Thermally Coupled Row-Column SNSPD Imaging Array

    Get PDF
    While single-pixel superconducting nanowire single photon detectors (SNSPDs) have demonstrated remarkable efficiency and timing performance from the UV to near-IR, scaling these devices to large imaging arrays remains challenging. Here, we propose a new SNSPD multiplexing system using thermal coupling and detection correlations between two photosensitive layers of an array. Using this architecture with the channels of one layer oriented in rows and the second layer in columns, we demonstrate imaging capability in 16-pixel arrays with accurate spot tracking at the few-photon level. We also explore the performance trade-offs of orienting the top layer nanowires parallel and perpendicular to the bottom layer. The thermally coupled row-column scheme is readily able to scale to the kilopixel size with existing readout systems and, when combined with other multiplexing architectures, has the potential to enable megapixel scale SNSPD imaging arrays

    Detecting a stochastic background of gravitational radiation: Signal processing strategies and sensitivities

    Get PDF
    We analyze the signal processing required for the optimal detection of a stochastic background of gravitational radiation using laser interferometric detectors. Starting with basic assumptions about the statistical properties of a stochastic gravity-wave background, we derive expressions for the optimal filter function and signal-to-noise ratio for the cross-correlation of the outputs of two gravity-wave detectors. Sensitivity levels required for detection are then calculated. Issues related to: (i) calculating the signal-to-noise ratio for arbitrarily large stochastic backgrounds, (ii) performing the data analysis in the presence of nonstationary detector noise, (iii) combining data from multiple detector pairs to increase the sensitivity of a stochastic background search, (iv) correlating the outputs of 4 or more detectors, and (v) allowing for the possibility of correlated noise in the outputs of two detectors are discussed. We briefly describe a computer simulation which mimics the generation and detection of a simulated stochastic gravity-wave signal in the presence of simulated detector noise. Numerous graphs and tables of numerical data for the five major interferometers (LIGO-WA, LIGO-LA, VIRGO, GEO-600, and TAMA-300) are also given. The treatment given in this paper should be accessible to both theorists involved in data analysis and experimentalists involved in detector design and data acquisition.Comment: 81 pages, 30 postscript figures, REVTE

    N′-Benzoyl-N,N-diethyl­thio­urea: a monoclinic polymorph

    Get PDF
    In the crystal of the title compound, C12H16N2OS, inversion dimers linked by pairs of N—H⋯S hydrogen bonds occur, generating R 2 2(8) loops. The mol­ecules are also linked by weak C—H⋯O hydrogen bonds. The structure is isostructural with that of N′-benzoyl-N,N-diethyl­seleno­urea [Bruce et al. (2007 ▶). New J. Chem. 31, 1647–1653]

    Large active-area superconducting microwire detector array with single-photon sensitivity in the near-infrared

    Full text link
    Superconducting nanowire single photon detectors (SNSPDs) are the highest-performing technology for time-resolved single-photon counting from the UV to the near-infrared. The recent discovery of single-photon sensitivity in micrometer-scale superconducting wires is a promising pathway to explore for large active area devices with application to dark matter searches and fundamental physics experiments. We present 8-pixel 1mm21 mm^2 superconducting microwire single photon detectors (SMSPDs) with 1μm1\,\mathrm{\mu m}-wide wires fabricated from WSi and MoSi films of various stoichiometries using electron-beam and optical lithography. Devices made from all materials and fabrication techniques show saturated internal detection efficiency at 1064 nm in at least one pixel, and the best performing device made from silicon-rich WSi shows single-photon sensitivity in all 8 pixels and saturated internal detection efficiency in 6/8 pixels. This detector is the largest reported active-area SMSPD or SNSPD with near-IR sensitivity published to date, and the first report of an SMSPD array. By further optimizing the photolithography techniques presented in this work, a viable pathway exists to realize larger devices with cm2cm^2-scale active area and beyond

    Mid-infrared timing jitter of superconducting nanowire single-photon detectors

    Get PDF
    Detector timing jitter is a key parameter in advanced photon counting applications. Superconducting nanowire single-photon detectors offer the fastest timing jitter in the visible to telecom wavelength range and have demonstrated single-photon sensitivity in the mid-infrared spectral region. Here, we report on timing jitter in a NbTiN nanowire device from 1.56 to 3.5 lm wavelength, achieving a FWHM jitter from 13.2 to 30.3 ps. This study has implications for emerging time-correlated single-photon counting applications in the mid-infrared spectral region

    The efficacy of playing a virtual reality game in modulating pain for children with acute burn injuries: A randomized controlled trial [ISRCTN87413556]

    Get PDF
    BACKGROUND: The management of burn injuries is reported as painful, distressing and a cause of anxiety in children and their parents. Child's and parents' pain and anxiety, often contributes to extended time required for burns management procedures, in particular the process of changing dressings. The traditional method of pharmacologic analgesia is often insufficient to cover the burnt child's pain, and it can have deleterious side effects [1,2]. Intervention with Virtual Reality (VR) games is based on distraction or interruption in the way current thoughts, including pain, are processed by the brain. Research on adults supports the hypothesis that virtual reality has a positive influence on burns pain modulation. METHODS: This study investigates whether playing a virtual reality game, decreases procedural pain in children aged 5–18 years with acute burn injuries. The paper reports on the findings of a pilot study, a randomised trial, in which seven children acted as their own controls though a series of 11 trials. Outcomes were pain measured using the self-report Faces Scale and findings of interviews with parent/carer and nurses. RESULTS: The average pain scores (from the Faces Scale) for pharmacological analgesia only was, 4.1 (SD 2.9), while VR coupled with pharmacological analgesia, the average pain score was 1.3 (SD 1.8) CONCLUSION: The study provides strong evidence supporting VR based games in providing analgesia with minimal side effects and little impact on the physical hospital environment, as well as its reusability and versatility, suggesting another option in the management of children's acute pain

    Rivaroxaban or Aspirin for extended treatment of venous thromboembolism

    Get PDF
    Background: although many patients with venous thromboembolism require extended treatment, it is uncertain whether it is better to use full- or lower-intensity anticoagulation therapy or aspirin. Methods: in this randomized, double-blind, phase 3 study, we assigned 3396 patients with venous thromboembolism to receive either once-daily rivaroxaban (at doses of 20 mg or 10 mg) or 100 mg of aspirin. All the study patients had completed 6 to 12 months of anticoagulation therapy and were in equipoise regarding the need for continued anticoagulation. Study drugs were administered for up to 12 months. The primary efficacy outcome was symptomatic recurrent fatal or nonfatal venous thromboembolism, and the principal safety outcome was major bleeding. Results: a total of 3365 patients were included in the intention-to-treat analyses (median treatment duration, 351 days). The primary efficacy outcome occurred in 17 of 1107 patients (1.5%) receiving 20 mg of rivaroxaban and in 13 of 1127 patients (1.2%) receiving 10 mg of rivaroxaban, as compared with 50 of 1131 patients (4.4%) receiving aspirin (hazard ratio for 20 mg of rivaroxaban vs. aspirin, 0.34; 95% confidence interval [CI], 0.20 to 0.59; hazard ratio for 10 mg of rivaroxaban vs. aspirin, 0.26; 95% CI, 0.14 to 0.47; P<0.001 for both comparisons). Rates of major bleeding were 0.5% in the group receiving 20 mg of rivaroxaban, 0.4% in the group receiving 10 mg of rivaroxaban, and 0.3% in the aspirin group; the rates of clinically relevant nonmajor bleeding were 2.7%, 2.0%, and 1.8%, respectively. The incidence of adverse events was similar in all three groups. Conclusions: among patients with venous thromboembolism in equipoise for continued anticoagulation, the risk of a recurrent event was significantly lower with rivaroxaban at either a treatment dose (20 mg) or a prophylactic dose (10 mg) than with aspirin, without a significant increase in bleeding rates. (Funded by Bayer Pharmaceuticals; EINSTEIN CHOICE ClinicalTrials.gov number, NCT02064439)
    corecore