99 research outputs found

    Symbol error probability analysis of a multiuser detector for M-PSK signals based on successive cancellation

    Full text link

    Development of a polymer endovascular prosthesis and its implantation in porcine arteries

    Get PDF
    A polyethylene-terephthalate braided mesh stent has been developed for application in the (coronary) arterial tree. In vitro measurements showed that the radial pressure delivered by this device was in the same range as that of a stainless steel stent. Hysteresis-like behavior, however, occurred after constraining the polyester stent for a period of only 15 minutes on a delivery system for percutaneous implantation. This implies that the polymer stent must be mounted on this delivery system immediately before the placement procedure, and that either a diameter in the unconstrained condition must be selected, which is considerably larger than the diameter of the target vessel, or stent expansion has to be enhanced by balloon expansion. Taking into account the results obtained during the in vitro studies, we investigated the angiographic patency and histologic features after implantation of this polyester stent in peripheral arteries of pigs. In four animals eight stents were placed. Except for heparin during the implantation procedure only, antithrombotic or antiplatelet drugs were not administered. After 4 weeks repeat angiography was performed. Angiography revealed that five of the six correctly placed stents were patent. At autopsy, two additional patent stents proved to be located in the aortic bifurcation, probably due to failure of the delivery system. Quantitative assessment showed that the mean luminal diameters of the site of stent placement were 3.3 +/- 0.2 mm before, 3.2 +/- 0.2 mm immediately after, and 3.1 +/- 0.3 mm at 4 weeks after implantation. Histology demonstrated an inflammatory reaction of variable severity around the stent fibers. Quantitative histologic measurements showed that the thickness of the neointima was 114 +/- 38 mum after 4 weeks. In conclusion, polyester stents can be constructed with mechanical properties similar to stainless steel stents. Hysteresis-like behavior of polyester stents, however, influences the selection of the nominal stent diameter as well as the forces exerted to the vessel wall. After implantation in porcine peripheral arteries, five of six correctly placed stents were patent at 4 weeks. The extent of neointimal proliferation was similar to that observed after placement of metal stents in swine, despite the presence of a more pronounced inflammatory reaction

    Improved functionalization of oleic acid-coated iron oxide nanoparticles for biomedical applications

    Get PDF
    Superparamagnetic iron oxide nanoparticles can providemultiple benefits for biomedical applications in aqueous environments such asmagnetic separation or magnetic resonance imaging. To increase the colloidal stability and allow subsequent reactions, the introduction of hydrophilic functional groups onto the particles’ surface is essential. During this process, the original coating is exchanged by preferably covalently bonded ligands such as trialkoxysilanes. The duration of the silane exchange reaction, which commonly takes more than 24 h, is an important drawback for this approach. In this paper, we present a novel method, which introduces ultrasonication as an energy source to dramatically accelerate this process, resulting in high-quality waterdispersible nanoparticles around 10 nmin size. To prove the generic character, different functional groups were introduced on the surface including polyethylene glycol chains, carboxylic acid, amine, and thiol groups. Their colloidal stability in various aqueous buffer solutions as well as human plasma and serum was investigated to allow implementation in biomedical and sensing applications.status: publishe

    Linear Successive Interference Cancellation in DS-CDMA Systems

    No full text
    Successive interference cancellation techniques have the potential to reduce the interference and therefore increase the capacity of cellular radio systems. In this work, we analyze a linear DS-CDMA receiver utilizing soft feedback interference cancellation. To be able to meet diverse QoS requirements, we introduce a power control scheme that takes into account heterogeneous service levels as well as the impact of imperfect interference cancellation. We address the capacity resulting from this receiver and give its user capacity region on closed-form. We show that our results are general and provide a framework for capacity comparison for many proposed linear successive cancellation receiver models. Several receiver modifications are included, partial interference cancellation; when only part of the signal is canceled, and limited cancellation; when not every signal is canceled. We derive the minimum power solution of a single-cell, from which convergent multicellular distributed power control algorithms that iteratively update the powers are suggested. The numerical results show that there are large gains in user capacity from interference cancellation when the E b /I 0 requirements are high. However, regardless of the required targets the maximum capacity is always achieved through partial successive interference cancellation. It is also found that the power levels are sensitive to the cancellation e#ciency and worse performance than single-user detection can occur
    • …
    corecore