3,193 research outputs found

    Beam Performance of Tracking Detectors with Industrially Produced GEM Foils

    Full text link
    Three Gas-Electron-Multiplier tracking detectors with an active area of 10 cm x 10 cm and a two-dimensional, laser-etched orthogonal strip readout have been tested extensively in particle beams at the Meson Test Beam Facility at Fermilab. These detectors used GEM foils produced by Tech-Etch, Inc. They showed an efficiency in excess of 95% and spatial resolution better than 70 um. The influence of the angle of incidence of particles on efficiency and spatial resolution was studied in detail.Comment: 8 pages, 9 figures, accepted by Nuclear Instruments and Methods in Physics Research

    k-space Imaging of the Eigenmodes of Sharp Gold Tapers for Scanning Near-Field Optical Microscopy

    Full text link
    We investigate the radiation patterns of sharp conical gold tapers, designed as adiabatic nanofocusing probes for scanning near-field optical microscopy (SNOM). Field calculations show that only the lowest order eigenmode of such a taper can reach the very apex and thus induce the generation of strongly enhanced near-field signals. Higher order modes are coupled into the far field at finite distances from the apex. Here, we demonstrate experimentally how to distinguish and separate between the lowest and higher order eigenmodes of such a metallic taper by filtering in the spatial frequency domain. Our approach has the potential to considerably improve the signal-to-background ratio in spectroscopic experiments on the nanoscale

    Femoral head decentration on hip MRI: comparison between imaging planes, methods of contrast administration, and hip deformities.

    Get PDF
    OBJECTIVES To compare the prevalence of femoral head decentration (FHD) on different MR imaging planes in patients undergoing direct/indirect hip MR arthrography (MRA) with asymptomatic controls and to evaluate its association with osseous deformities. METHODS IRB-approved retrospective single-center study of symptomatic hips undergoing direct or indirect hip MRA at 3 T. Asymptomatic participants underwent non-contrast hip MRI at 3 T. FHD was defined as a continuous fluid layer between the acetabulum and femoral head and assessed on axial, sagittal and radial images. The association of intra-articular/intra-venous contrast agents and the prevalence of FHD was evaluated. The association of FHD with osseous deformities and joint damage was assessed using multiple logistic regression analysis. RESULTS Three-hundred ninety-four patients (447 hips, mean age 31 ± 9 years, 247 females) were included and compared to 43 asymptomatic controls (43 hips, mean age 31 ± 6 years, 26 females). FHD was most prevalent on radial images and more frequent in symptomatic hips (30% versus 2%, p < 0.001). FHD prevalence was not associated with the presence/absence of intra-articular contrast agents (30% versus 22%, OR = 1.5 (95% CI 0.9-2.5), p = 0.125). FHD was associated with hip dysplasia (OR = 6.1 (3.3-11.1), p < 0.001), excessive femoral torsion (OR = 3.0 (1.3-6.8), p = 0.010), and severe cartilage damage (OR = 3.6 (2.0-6.7), p < 0.001). CONCLUSION While rare in asymptomatic patients, femoral head decentration in symptomatic patients is associated with osseous deformities predisposing to hip instability, as well as with extensive cartilage damage. CRITICAL RELEVANCE STATEMENT Decentration of the femoral head on radial MRA may be interpreted as a sign of hip instability in symptomatic hips without extensive cartilage defects. Its presence could unmask hip instability and yield promise in surgical decision-making. KEY POINTS The best method of identifying femoral head decentration is radial MRI. The presence/absence of intra-articular contrast is not associated with femoral head decentration. Femoral head decentration is associated with hip deformities predisposing to hip instability

    Generation of Stable, Low-Divergence Electron Beams by Laser-Wakefield Acceleration in a Steady-State-Flow Gas Cell

    Get PDF
    Laser-driven, quasimonoenergetic electron beams of up to ~200 MeV in energy have been observed from steady-state-flow fas cells. These beams emitted within a low-divergence cone of 2.1 ± 0.5 mrad FWHM display unprecedented shot-to-shot stability in energy (2.5% rms), pointing (1.4 mrad rms), and charge (16% rms) owing to a highly reproducible gas-density profile within the interaction volume. Laser-wakefield acceleration in gas cells of this type provides a simple and reliable source of relativistic electrons suitable for applications such as the production of extreme-ultraviolet undulator radiation

    Antiphospholipid antibodies in black south africans with hiv and acute coronary syndromes: prevalence and clinical correlates

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>HIV infection is associated with a high prevalence of antiphospholipid antibodies (aPL) and increased thrombotic events but the aetiopathogenic link between the two is unclear.</p> <p>Findings</p> <p>Prospective single centre study from Soweto, South Africa, comparing the prevalence of aPL in highly active anti-retroviral therapy (HAART) naïve HIV positive and negative patients presenting with Acute Coronary Syndromes (ACS). Between March 2004 and February 2008, 30 consecutive black South African HIV patients with ACS were compared to 30 black HIV negative patients with ACS. The HIV patients were younger (43 ± 7 vs. 54 ± 13, p = 0.004) and besides smoking (73% vs. 33%, p = 0.002) and lower HDL levels (0.8 ± 0.3 vs. 1.1 ± 0.4, p = 0.001) had fewer risk factors than the control group. HIV patients had a higher prevalence of anticardiolipin (aCL) IgG (47% vs. 10%, p = 0.003) and anti-prothrombin (aPT) IgG antibodies (87% vs. 21%, p < 0.001) but there was no difference in the prevalence of the antiphospholipid syndrome (44% vs. 24%, p = N/S) and aPL were not predictive of clinical or angiographic outcomes.</p> <p>Conclusions</p> <p>Treatment naïve black South African HIV patients with ACS are younger with fewer traditional coronary risk factors than HIV negative patients but have a higher prevalence and different expression of aPL which is likely to be an epiphenomenon of the HIV infection rather than causally linked to thrombosis and the pathogenesis of ACS.</p

    Axionic D3-D7 Inflation

    Get PDF
    We study the motion of a D3 brane moving within a Type IIB string vacuum compactified to 4D on K3 x T_2/Z_2 in the presence of D7 and O7 planes. We work within the effective 4D supergravity describing how the mobile D3 interacts with the lightest bulk moduli of the compactification, including the effects of modulus-stabilizing fluxes. We seek inflationary solutions to the resulting equations, performing our search numerically in order to avoid resorting to approximate parameterizations of the low-energy potential. We consider uplifting from D-terms and from the supersymmetry-breaking effects of anti-D3 branes. We find examples of slow-roll inflation (with anti-brane uplifting) with the mobile D3 moving along the toroidal directions, falling towards a D7-O7 stack starting from the antipodal point. The inflaton turns out to be a linear combination of the brane position and the axionic partner of the K3 volume modulus, and the similarity of the potential along the inflaton direction with that of racetrack inflation leads to the prediction n_s \le 0.95 for the spectral index. The slow roll is insensitive to most of the features of the effective superpotential, and requires a one-in-10^4 tuning to ensure that the torus is close to square in shape. We also consider D-term inflation with the D3 close to the attractive D7, but find that for a broad (but not exhaustive) class of parameters the conditions for slow roll tend to destabilize the bulk moduli. In contrast to the axionic case, the best inflationary example of this kind requires the delicate adjustment of potential parameters (much more than the part-per-mille level), and gives inflation only at an inflection point of the potential (and so suffers from additional fine-tuning of initial conditions to avoid an overshoot problem).Comment: 29 pages, 5 figure

    Causes of metabolic acidosis in canine hemorrhagic shock: role of unmeasured ions

    Get PDF
    Introduction: Metabolic acidosis during hemorrhagic shock is common and conventionally considered to be due to hyperlactatemia. There is increasing awareness, however, that other nonlactate, unmeasured anions contribute to this type of acidosis. Methods: Eleven anesthetized dogs were hemorrhaged to a mean arterial pressure of 45 mm Hg and were kept at this level until a metabolic oxygen debt of 120 mLO2/kg body weight had evolved. Blood pH, partial pressure of carbon dioxide, and concentrations of sodium, potassium, magnesium, calcium, chloride, lactate, albumin, and phosphate were measured at baseline, in shock, and during 3 hours post-therapy. Strong ion difference and the amount of weak plasma acid were calculated. To detect the presence of unmeasured anions, anion gap and strong ion gap were determined. Capillary electrophoresis was used to identify potential contributors to unmeasured anions. Results: During induction of shock, pH decreased significantly from 7.41 to 7.19. The transient increase in lactate concentration from 1.5 to 5.5 mEq/L during shock was not sufficient to explain the transient increases in anion gap (+11.0 mEq/L) and strong ion gap (+7.1 mEq/L), suggesting that substantial amounts of unmeasured anions must have been generated. Capillary electrophoresis revealed increases in serum concentration of acetate (2.2 mEq/L), citrate (2.2 mEq/L), alpha-ketoglutarate (35.3 microEq/L), fumarate (6.2 microEq/L), sulfate (0.1 mEq/L), and urate (55.9 microEq/L) after shock induction. Conclusion: Large amounts of unmeasured anions were generated after hemorrhage in this highly standardized model of hemorrhagic shock. Capillary electrophoresis suggested that the hitherto unmeasured anions citrate and acetate, but not sulfate, contributed significantly to the changes in strong ion gap associated with induction of shock

    The soft X-ray properties of quasars in the Sloan Digital Sky Survey

    Full text link
    We use the ROSAT All Sky Survey (RASS) to study the soft X-ray properties of a homogeneous sample of 46,420 quasars selected from the third data release of the Sloan Digital Sky Survey (SDSS). Optical luminosities, both at rest-frame 2500\AA (L2500L_{2500}) and in [OIII] (L[OIII]L_{[\rm{OIII}]}) span more than three orders of magnitude, while redshifts range over 0.1<z<5.40.1<z<5.4. We detect 3366 quasars directly in the observed 0.1--2.4 keV band. Sub-samples of radio-loud and radio-quiet objects (RLQs and RQQs) are obtained by cross-matching with the FIRST catalogue. We study the distribution of X-ray luminosity as a function of optical luminosity, redshift and radio power using both individual detections and stacks of complete sets of similar quasars. At every optical luminosity and redshift \log L_{2\kev} is, to a good approximation, normally distributed with dispersion 0.40\sim 0.40, at least brightwards of the median X-ray luminosity. This median X-ray luminosity of quasars is a power law of optical luminosity with index 0.53\sim 0.53 for L2500L_{2500} and 0.30\sim 0.30 for L[OIII]L_{[\rm{OIII}]}. RLQs are systematically brighter than RQQs by about a factor of 2 at given optical luminosity. The zero-points of these relations increase systematically with redshift, possibly in different ways for RLQs and RQQs. Evolution is particularly strong at low redshift and if the optical luminosity is characterised by L[OIII]L_{[\rm{OIII}]}. At low redshift and at given L[OIII]L_{[\rm{OIII}]} the soft X-ray emission from type II AGN is more than 100 times weaker than that from type I AGN.Comment: 16 pages, 15 figures, 3 tables, replaced with final version accepted by MNRA
    corecore