198 research outputs found

    Calibration of Boom Sprayers Using Charts to Reduce Math Calculations

    Get PDF
    The calibration of boom sprayers, although not difficult, is often neglected by producers. This article explains procedures for calibrating boom sprayers using charts and techniques rather than math calculations. It provides Extension educators with information they can use to give producers a quick and easy way to regularly calibrate their spray equipment

    Maintaining Electric Motors Used for Irrigation

    Get PDF

    Utah Regional Differences in Respirator Use and Fit Testing among Pesticide Applicators

    Get PDF
    The purpose of this study was to determine regional differences within Utah in response to piloting a mobile respirator training and fit assessment program for pesticide applicators. The objectives were to describe worker perceptions of respirator use and training experiences. Pilot trainings were offered in two southern counties and two northern counties of Utah. A total of 141 individuals completed the post-training questionnaire regarding use and fit testing experience with respirators as well as perceptions of the benefits to protecting respiratory health. The majority of respondents were male (95.7%, f = 112). The proportion of participants in the southern counties who had respirator training experience (61.0%, f = 25) was not significantly higher (X2 = 3.763, df = 1, p = 0.05) than the proportion of participants in the northern counties (43.0%, f = 43). Three-fourths (73.5%, f = 72) of participants in the northern counties agreed that they expect to wear a respirator in dusty conditions, while two-thirds (61.0%, f = 25) of participants in the southern counties agreed that they expect to wear a respirator in dusty conditions. The results indicated that more training should be done to improve perceptions and beliefs about using respirators. A high priority for this population will be identification of comfortable respirator options as well as communicating the importance of proper fit testing

    Maintenance of Wheelmove Irrigation Systems

    Get PDF

    Iron bioavailability: UK Food Standards Agency workshop report

    Get PDF
    The UK Food Standards Agency convened a group of expert scientists to review current research investigating factors affecting iron status and the bioavailability of dietary iron. Results presented at the workshop show menstrual blood loss to be the major determinant of body iron stores in premenopausal women. In the presence of abundant and varied food supplies, the health consequences of lower iron bioavailability are unclear and require further investigatio

    Low Intensity Vibrations Augment Mesenchymal Stem Cell Proliferation and Differentiation Capacity During \u3ci\u3ein vitro\u3c/i\u3e Expansion

    Get PDF
    A primary component of exercise, mechanical signals, when applied in the form of low intensity vibration (LIV), increases mesenchymal stem cell (MSC) osteogenesis and proliferation. While it is generally accepted that exercise effectively combats the deleterious effects of aging in the musculoskeletal system, how long-term exercise affects stem cell aging, which is typified by reduced proliferative and differentiative capacity, is not well explored. As a first step in understanding the effect of long-term application of mechanical signals on stem cell function, we investigated the effect of LIV during in vitro expansion of MSCs. Primary MSCs were subjected to either a control or to a twice-daily LIV regimen for up to sixty cell passages (P60) under in vitro cell expansion conditions. LIV effects were assessed at both early passage (EP) and late passage (LP). At the end of the experiment, P60 cultures exposed to LIV maintained a 28% increase of cell doubling and a 39% reduction in senescence-associated β-galactosidase activity (p \u3c 0.01) but no changes in telomere lengths and p16INK4a levels were observed. Prolonged culture-associated decreases in osteogenic and adipogenic capacity were partially protected by LIV in both EP and LP groups (p \u3c 0.05). Mass spectroscopy of late passage MSC indicated a synergistic decrease of actin and microtubule cytoskeleton-associated proteins in both control and LIV groups while LIV induced a recovery of proteins associated with oxidative reductase activity. In summary, our findings show that the application of long-term mechanical challenge (+LIV) during in vitro expansion of MSCs for sixty passages significantly alters MSC proliferation, differentiation and structure. This suggests LIV as a potential tool to investigate the role of physical activity during aging

    Pennsylvania Folklife Vol. 33, No. 4

    Get PDF
    • I Remember Well: Thirty-Five Years of the Kutztown Folk Festival • Furniture Graining • Old Fashioned Clear Toy Candy • Metal Etching • Stenciling • Baskets and Basket Weavers • Apple Butter: Then and Now • Festival Focus • Festival Programs • 20th Annual Quilting Contest • Quilts and Quilt Marking • The Art of the Pennsylvania Dutch • Music on the Main Stage • Scratchboard • Pennsylvania Dutch Folk Art in Wood • The Windsor Chair • Hex Signshttps://digitalcommons.ursinus.edu/pafolklifemag/1104/thumbnail.jp

    Length of carotid stenosis predicts peri-procedural stroke or death and restenosis in patients randomized to endovascular treatment or endarterectomy.

    Get PDF
    BACKGROUND: The anatomy of carotid stenosis may influence the outcome of endovascular treatment or carotid endarterectomy. Whether anatomy favors one treatment over the other in terms of safety or efficacy has not been investigated in randomized trials. METHODS: In 414 patients with mostly symptomatic carotid stenosis randomized to endovascular treatment (angioplasty or stenting; n = 213) or carotid endarterectomy (n = 211) in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS), the degree and length of stenosis and plaque surface irregularity were assessed on baseline intraarterial angiography. Outcome measures were stroke or death occurring between randomization and 30 days after treatment, and ipsilateral stroke and restenosis ≥50% during follow-up. RESULTS: Carotid stenosis longer than 0.65 times the common carotid artery diameter was associated with increased risk of peri-procedural stroke or death after both endovascular treatment [odds ratio 2.79 (1.17-6.65), P = 0.02] and carotid endarterectomy [2.43 (1.03-5.73), P = 0.04], and with increased long-term risk of restenosis in endovascular treatment [hazard ratio 1.68 (1.12-2.53), P = 0.01]. The excess in restenosis after endovascular treatment compared with carotid endarterectomy was significantly greater in patients with long stenosis than with short stenosis at baseline (interaction P = 0.003). Results remained significant after multivariate adjustment. No associations were found for degree of stenosis and plaque surface. CONCLUSIONS: Increasing stenosis length is an independent risk factor for peri-procedural stroke or death in endovascular treatment and carotid endarterectomy, without favoring one treatment over the other. However, the excess restenosis rate after endovascular treatment compared with carotid endarterectomy increases with longer stenosis at baseline. Stenosis length merits further investigation in carotid revascularisation trials

    The Role of Lactic Acid Adsorption by Ion Exchange Chromatography

    Get PDF
    Background: The polyacrylic resin Amberlite IRA-67 is a promising adsorbent for lactic acid extraction from aqueous solution, but little systematic research has been devoted to the separation efficiency of lactic acid under different operating conditions. Methodology/Principal Findings: In this paper, we investigated the effects of temperature, resin dose and lactic acid loading concentration on the adsorption of lactic acid by Amberlite IRA-67 in batch kinetic experiments. The obtained kinetic data followed the pseudo-second order model well and both the equilibrium and ultimate adsorption slightly decreased with the increase of the temperature at 293–323K and 42.5 g/liter lactic acid loading concentration. The adsorption was a chemically heterogeneous process with a mean free energy value of 12.18 kJ/mol. According to the Boyd _ plot, the lactic acid uptake process was primarily found to be an intraparticle diffusion at a lower concentration (,50 g/liter) but a film diffusion at a higher concentration (.70 g/liter). The values of effective diffusion coefficient D i increased with temperature. By using our Equation (21), the negative values of DGu and DHu revealed that the adsorption process was spontaneous and exothermic. Moreover, the negative value of DSu reflected the decrease of solid-liquid interface randomness at the solid-liquid interface when adsorbing lactic acid on IRA-67. Conclusions/Significance: With the weakly basic resin IRA-67, in situ product removal of lactic acid can be accomplishe

    Reported patterns of vaping to support long-term abstinence from smoking: a cross-sectional survey of a convenience sample of vapers

    Get PDF
    Background: E-cigarettes are the most popular aid to smoking cessation attempts in England and the USA. This research examined associations between e-cigarette device characteristics and patterns of use, tobacco-smoking relapse, and smoking abstinence. Methods: A convenience sample of 371 participants with experience of vaping, and tobacco-smoking abstinence and/or relapse completed an online cross-sectional survey about e-cigarettes. Factors associated with smoking relapse were examined using multiple linear and logistic regression models. Results: Most participants were self-reported long-term abstinent smokers (86.3%) intending to continue vaping. Most initiated e-cigarette use with a vape pen (45.8%) or cig-a-like (38.7%) before moving onto a tank device (89%). Due to missing data, managed through pairwise deletion, only around 70 participants were included in some of the main analyses. Those using a tank or vape pen appeared less likely to relapse than those using a cig-a-like (tank vs. cig-a-like OR = 0.06, 95% CI 0.01-0.64, p = 0.019). There was an inverse association between starting self-reported e-cigarette liquid nicotine concentration and relapse, interacting with device type (OR = 0.79, 95% CI 0.63-0.99, p = 0.047), suggesting that risk of relapse may have been greater if starting with a low e-cigarette liquid nicotine concentration and/or cig-a-like device. Participants reported moving from tobacco-flavored cig-a-likes to fruit/sweet/food flavors with tank devices. Conclusions: Knowledge of how people have successfully maintained tobacco-smoking abstinence using vaping could help other tobacco smokers wishing to quit tobacco smoking through vaping
    • …
    corecore