2,528 research outputs found

    Reducing the critical switching current in nanoscale spin valves

    Full text link
    The current induced magnetization reversal in nanoscale spin valves is a potential alternative to magnetic field switching in magnetic memory devices. We show that the critical switching current can be decreased by an order of magnitude by strategically distributing the resistances in the magnetically active region of the spin valve. In addition, we simulate full switching curves and predict a new precessional state.Comment: mistake corrected, references added, 4 page

    Harmonically trapped fermions in one dimension: A finite temperature lattice Monte Carlo study

    Full text link
    We study a one-dimensional two-component Fermi gas in a harmonic trapping potential using finite temperature lattice quantum Monte Carlo methods. We are able to compute observables in the canonical ensemble via an efficient projective approach. Results for density profiles, correlations, as well as energy-related observables are presented for systems with up to 80 particles and various temperatures. Our simulations reproduce known numerical results and compare well against available experimental data close to the ground state, while at higher temperature they are benchmarked against the exact solution of the two particle system. This provides an indication that a standard lattice discretization is sufficient to capture the physics of the trapped system. In the special case of a spin-imbalanced gas, we find no sign problem in the parameter ranges studied, allowing access without the need of specialized methods. This includes simulations close to the ground state and at large population imbalance, where we present results for density correlations, indicating pairing at finite total momentum.Comment: 11 pages, 6 figure

    Determination of thoracic and lumbar spinal processes by their percentage position between C7 and the PSIS level

    Get PDF
    Accurate measurements of spinal movement require reliable determination of anatomical landmarks. Current methods of identifying these are not sufficiently reliable or valid for this purpose. A reliable and convenient method of placing markers on selected vertebra is needed to compare measurements between different testers, subjects and sessions

    Preschool child care and child well-being in Germany : does the migrant experience differ?

    Get PDF
    Because the value of preschool child care is under intensive debate among both policy - makers and society in general,this paper analyzes the relation between preschool care and the well-being of children and adolescents in Germany. It also examines differences in outcomes based on child socioeconomic background by focusing on the heterogeneous effects for migrant children. Our findings, based on data from the German Health Interview and Examination Survey of Children and Adolescents, suggest that children who have experienced child care have a slightly lower well-being overall. For migrant children, however, the outcomes indicate a positive relation

    Rewarding behavior with a sweet food strengthens its valuation

    Get PDF
    Sweet foods are commonly used as rewards for desirable behavior, specifically among children. This study examines whether such practice may contribute to reinforce the valuation of these foods. Two experiments were conducted, one with children, the other with rats. The first study, conducted with first graders (n = 214), shows that children who receive a food reward for performing a cognitive task subsequently value the food more compared to a control group who received the same food without performing any task. The second study, conducted on rats (n = 64), shows that rewarding with food also translates into higher calorie intake over a 24-hour period. These results suggest that the common practice of rewarding children with calorie-dense sweet foods is a plausible contributing factor to obesity and might therefore be ill advised. © 2021 This is an open access article, free of all copyright, and may be freely reproduced, distributed, transmitted, modified, built upon, or otherwise used by anyone for any lawful purpose. The work is made available under the Creative Commons CC0 public domain dedication

    FAMULUS: interactive annotation and feedback generation for teaching diagnostic reasoning

    Get PDF
    Our proposed system FAMULUS helps students learn to diagnose based on automatic feedback in virtual patient simulations, and it supports instructors in labeling training data. Diagnosing is an exceptionally difficult skill to obtain but vital for many different professions (e.g., medical doctors, teachers). Previous case simulation systems are limited to multiple-choice questions and thus cannot give constructive individualized feedback on a student’s diagnostic reasoning process. Given initially only limited data, we leverage a (replaceable) NLP model to both support experts in their further data annotation with automatic suggestions, and we provide automatic feedback for students. We argue that because the central model consistently improves, our interactive approach encourages both students and instructors to recurrently use the tool, and thus accelerate the speed of data creation and annotation. We show results from two user studies on diagnostic reasoning in medicine and teacher education and outline how our system can be extended to further use cases

    Final Report on the Detection of Green Monopropellants

    Get PDF
    In 2014, National Aeronautics and Space Administration (NASA) Kennedy Space Center (KSC) funded a project titled "Familiarization and Detection of Green Monopropellants" utilizing Independent Research and Technology Development (IR&TD) and Center Innovation Fund (CIF) funding. The purpose of the project was to evaluate methods of detection for ammonium dinitramide (ADN) and hydroxylammonium nitrate (HAN). An Engineering Services Contract (ESC) task order was created with the scope of evaluation of several methods of detecting ADN- and HAN-based propellants, as well as development of methods for detection. Detection methods include developed methods such as colorimetric indicating absorbent socks, and commercial-off-the- shelf (COTS) units for ammonia detection. An additional goal of the task order was for ESC to become familiar with ADN's and HAN's material properties and material compatibility. Two approaches were initially investigated as possible methods for the detection of HAN (or AFM315E) and ADN (or LMP-103S). These approaches were colorimetric analysis and instrumentation-based COTS vapor sensors utilization. Initial testing showed that the relatively non-existent vapor pressure of the AF-M315E (of which HAN is a major component) propellant would make the use of COTS sensors difficult for real-time area monitoring of HAN; a small response was detected through the use of active COTS sensors, including the RAE Systems MultiRAE Lite and Drager X-act (registered) 5000, but the levels detected were below the threshold limit value for the toxic gas ammonia. Therefore, a detection system ased upon a colorimetric indicator impregnated into an absorbent material was developed. Preliminary analysis (ESC-245-FDG-001) identified a particularly outstanding candidate as a colorimetric indicator for the detection of the presence of AF-M315E in the form of a Methyl Red (Basic) indicator. Materials impregnated with this indicator exhibit significant color change and the materials are not susceptible to interference from exposure to water or carbon dioxide. The completed detection system for HAN/AF-M315E consists of absorbent socks packed with Fisher Universal Spill Absorbent capable of absorbing and containing any propellant spills that they come into contact with along with indicating wipes. The absorbent socks are also chemically treated with a Methyl Red (Basic) indicator solution to provide the end user with a visual indication that a leak has occurred and proper protective precautions must be undertaken. An added benefit of this detection system is that the absorbent socks should neutralize/absorb any commodity that it comes into contact with (until saturation is reached). Additional adsorbent socks can be deployed until a color change is not seen, indicating that the HAN/AF-M315E contamination has been contained. The indicating wipes provide the user the opportunity to wipe surfaces to determine if there is any HAN/AF-M315E or HAN/AFM315E residue present. The wipes should allow the detection of fuel levels that may be too small to detect with the absorbent socks. The development of a detection system for the ADN/LMP-103S focused on the use of various COTS sensors used as real-time area monitoring devices and personal dosimeters. These COTS based sensor systems were of several different types, including both actively pumped and diffusion-based passive systems, as well as a "rope"-type chemical sensing cable. The results highlighted some of the major differences between the two monopropellants undergoing evaluation. Unlike HAN, ADN (which is the major constituent of LMP-103S) exhibits a much more volatile nature in comparison to AF-M315E. In fact, testing showed that a large percentage of the fuel was lost during the sampling measurement (greater than 10 percent by mass); although this testing cannot tell if the volatile component is the ADN itself or another component of the monopropellant solution. Not surprisingly, all four of the procured vapor-based COTS sensors showed positive results when exposed to solutions of the LMP-103S (ESC-245-FDG-002). The completed detection system for ADN/LMP-103S consists of a combination of two of the tested COTS sensor systems, the RAE Systems MultiRAE Lite and the BW Technologies GasAlert Extreme. These systems are meant to be used in conjunction with one another, which allows for the end-user to have both real-time area monitoring (MultiRAE Lite) as well as a personal dosimeter device (GasAlert Extreme) which can be worn as additional personal protective equipment. An stainless steel extension wand was fabricated and included in the detection system for the MultiRAE Lite to allow for more remote sensing, and connects via the active pumping inlet of the sensor. As stated, the final results of this testing resulted in the production of two "kits" which can be used for the detection of HAN/AF-M315E and ADN/LMP-103s (ESC-245-FDG-003)
    • …
    corecore