12 research outputs found

    Barrier efficiency of sponge-like La2Zr2O7 buffer layers for YBCO-coated conductors

    Full text link
    Solution derived La2Zr2O7 films have drawn much attention for potential applications as thermal barriers or low-cost buffer layers for coated conductor technology. Annealing and coating parameters strongly affect the microstructure of La2Zr2O7, but different film processing methods can yield similar microstructural features such as nanovoids and nanometer-sized La2Zr2O7 grains. Nanoporosity is a typical feature found in such films and the implications for the functionality of the films is investigated by a combination of scanning transmission electron microscopy, electron energy-loss spectroscopy and quantitative electron tomography. Chemical solution based La2Zr2O7 films deposited on flexible Ni-5at.%W substrates with a {100} biaxial texture were prepared for an in-depth characterization. A sponge-like structure composed of nanometer sized voids is revealed by high-angle annular dark-field scanning transmission electron microscopy in combination with electron tomography. A three-dimensional quantification of nanovoids in the La2Zr2O7 film is obtained on a local scale. Mostly non-interconnected highly facetted nanovoids compromise more than one-fifth of the investigated sample volume. The diffusion barrier efficiency of a 170 nm thick La2Zr2O7 film is investigated by STEM-EELS yielding a 1.8 \pm 0.2 nm oxide layer beyond which no significant nickel diffusion can be detected and intermixing is observed. This is of particular significance for the functionality of YBa2Cu3O7-{\delta} coated conductor architectures based on solution derived La2Zr2O7 films as diffusion barriers.Comment: Accepted for publication in Superconductor Science and Technolog

    Geometric reconstruction methods for electron tomography

    Get PDF
    Electron tomography is becoming an increasingly important tool in materials science for studying the three-dimensional morphologies and chemical compositions of nanostructures. The image quality obtained by many current algorithms is seriously affected by the problems of missing wedge artefacts and nonlinear projection intensities due to diffraction effects. The former refers to the fact that data cannot be acquired over the full 180180^\circ tilt range; the latter implies that for some orientations, crystalline structures can show strong contrast changes. To overcome these problems we introduce and discuss several algorithms from the mathematical fields of geometric and discrete tomography. The algorithms incorporate geometric prior knowledge (mainly convexity and homogeneity), which also in principle considerably reduces the number of tilt angles required. Results are discussed for the reconstruction of an InAs nanowire

    Three-Dimensional Visualization and Characterization of Polymeric Self-Assemblies by Transmission Electron Microtomography

    Get PDF
    Self-assembling structures and their dynamical processes in polymeric systems have been investigated using three-dimensional transmission electron microscopy (3D-TEM). Block copolymers (BCPs) self-assemble into nanoscale periodic structures called microphase-separated structures, a deep understanding of which is important for creating nanomaterials with superior physical properties, such as high-performance membranes with well-defined pore size and high-density data storage media. Because microphase-separated structures have become increasingly complicated with advances in precision polymerization, characterizing these complex morphologies is becoming increasingly difficult. Thus, microscopes capable of obtaining 3D images are required. In this article, we demonstrate that 3D-TEM is an essential tool for studying BCP nanostructures, especially those self-assembled during dynamical processes and under confined conditions.The first example is a dynamical process called order-order transitions (OOTs). Upon changing temperature or pressure or applying an external field, such as a shear flow or electric field, BCP nanostructures transform from one type of structure to another. The OOTs are examined by freezing the specimens in the middle of the OOT and then observing the boundary structures between the preexisting and newly formed nanostructures in three-dimensions. In an OOT between the bicontinuous double gyroid and hexagonally packed cylindrical structures, two different types of epitaxial phase transition paths are found. Interestingly, the paths depend on the direction of the OOT. The second example is BCP self-assemblies under confinement that have been examined by 3D-TEM. A variety of intriguing and very complicated 3D morphologies can be formed even from the BCPs that self-assemble into simple nanostructures, such as lamellar and cylindrical structures in the bulk (in free space).Although 3D-TEM is becoming more frequently used for detailed morphological investigations, it is generally used to study static nanostructures. Although OOTs are dynamical processes, the actual experiment is done in the static state, through a detailed morphological study of a snapshot taken during the OOT. Developing time-dependent nanoscale 3D imaging has become a hot topic. Here, the two main problems preventing the development of in situ electron tomography for polymer materials are addressed. First, the staining protocol often used to enhance contrast for electrons is replaced by a new contrast enhancement based on chemical differences between polymers. In this case, no staining is necessary. Second, a new 3D reconstruction algorithm allows us to obtain a high-contrast, quantitative 3D image from fewer projections than is required for the conventional algorithm to achieve similar contrast, reducing the number of projections and thus the electron beam dose. Combining these two new developments is expected to open new doors to 3D in situ real-time structural observation of polymer materials

    Fourth-Generation Epac-Based FRET Sensors for cAMP Feature Exceptional Brightness, Photostability and Dynamic Range: Characterization of Dedicated Sensors for FLIM, for Ratiometry and with High Affinity

    Get PDF
    Epac-based FRET sensors have been widely used for the detection of cAMP concentrations in living cells. Originally developed by us as well as others, we have since then reported several important optimizations that make these sensors favourite among many cell biologists. We here report cloning and characterization of our fourth generation of cAMP sensors, which feature outstanding photostability, dynamic range and signal-to-noise ratio. The design is based on mTurquoise2, currently the brightest and most bleaching-resistant donor, and a new acceptor cassette that consists of a tandem of two cp173Venus fluorophores. We also report variants with a single point mutation, Q270E, in the Epac moiety, which decreases the dissociation constant of cAMP from 9.5 to 4 μM, and thus increases the affinity ~ 2.5-fold. Finally, we also prepared and characterized dedicated variants with non-emitting (dark) acceptors for single-wavelength FLIM acquisition that display an exceptional near-doubling of fluorescence lifetime upon saturation of cAMP levels. We believe this generation of cAMP outperforms all other sensors and therefore recommend these sensors for all future studies

    Two-part implants inserted in a one-stage or a two-stage procedure - A prospective comparative study

    No full text
    Objective: The aim of this study was to evaluate the feasibility of using a two-part implant system in a one-stage procedure and to monitor the microflora in the peri-implant area in relation to clinical and radiographic outcome. Material and Methods: After randomisation, 40 edentulous patients (Cawood & Howell class V-VI) received two IMZ implants in the anterior mandible inserted by either a one-stage (n=20) or a two-stage (n=20) surgical procedure for overdenture treatment. A standardised clinical and radiographic evaluation was performed after denture insertion as well as 6 and 12 months thereafter. Twelve months after loading, peri-implant samples were collected and analysed for the presence of putative periodontal pathogens using culture technique. Results: No striking differences were found between the two groups with regard to the clinical parameters during the evaluation period. The mean bone loss in the first year of functioning was 0.6 mm in both groups. With regard to the gingiva score, plaque score, bleeding score or bone loss between T0 and T12, no associations were found with the presence of the cultured microorganisms. An association was present between pockets greater than or equal to4mm and the presence of Peptostreptococcus micros in the two-stage group. Conclusions: The short-term results indicate that two-part implants inserted in a one-stage procedure may be as predictable as inserted in the common two-stage procedure. The peri-implant sulcus can and does harbour potential periodontal pathogens without significant signs of tissue breakdown
    corecore